메뉴 건너뛰기




Volumn 16, Issue 5, 2003, Pages 385-391

Device Closure of Patent Ductus Arteriosus

Author keywords

[No Author keywords available]

Indexed keywords

ARTERY PROSTHESIS; CONFERENCE PAPER; DEVICE; DEVICE CLOSURE; HEART CATHETERIZATION; HUMAN; OUTCOMES RESEARCH; PATENT DUCTUS ARTERIOSUS; PRIORITY JOURNAL; AORTOGRAPHY; BLOOD VESSEL PROSTHESIS; FOLLOW UP; INFANT; INSTRUMENTATION; METHODOLOGY; RADIOGRAPHY; REVIEW; TREATMENT OUTCOME;

EID: 0142154898     PISSN: 08964327     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8183.2003.01005.x     Document Type: Conference Paper
Times cited : (14)

References (42)
  • 1
    • 0014235755 scopus 로고
    • Natural history of persistent ductus arteriosus
    • Campbell M. Natural history of persistent ductus arteriosus. Br Heart J 1968;30:4-13.
    • (1968) Br Heart J , vol.30 , pp. 4-13
    • Campbell, M.1
  • 2
    • 0027422797 scopus 로고
    • Persistent ductus arteriosus: Is closure indicated also in asymptomatic adults with small ductus and minor shunts?
    • Schrader R, Kadel C. Persistent ductus arteriosus: Is closure indicated also in asymptomatic adults with small ductus and minor shunts? Z Kardiol 1993;82:563-567.
    • (1993) Z Kardiol , vol.82 , pp. 563-567
    • Schrader, R.1    Kadel, C.2
  • 3
    • 0015291352 scopus 로고
    • Surgical treatment of patent ductus arteriosus in the adult
    • Black LL, Goldman BS. Surgical treatment of patent ductus arteriosus in the adult. Ann Surg 1972;175:290-293.
    • (1972) Ann Surg , vol.175 , pp. 290-293
    • Black, L.L.1    Goldman, B.S.2
  • 4
    • 0017816106 scopus 로고
    • Ligation of a patent ductus: Technical considerations at different ages
    • Wright JS, Newman DC. Ligation of a patent ductus: Technical considerations at different ages. J Thorac Cardiovasc Surg 1978;75:695-698.
    • (1978) J Thorac Cardiovasc Surg , vol.75 , pp. 695-698
    • Wright, J.S.1    Newman, D.C.2
  • 5
    • 0014096990 scopus 로고
    • Closure of a persistent ductus arteriosus without thoracotomy
    • Porstmann W, Wierny L, Warnke H. Closure of a persistent ductus arteriosus without thoracotomy. Ger Med Mon 1967;12:259-261.
    • (1967) Ger Med Mon , vol.12 , pp. 259-261
    • Porstmann, W.1    Wierny, L.2    Warnke, H.3
  • 6
    • 0023153198 scopus 로고
    • Nonsurgical closure of patent ductus PDA occluder system
    • Rashkind WJ, Mullins CE, Hellenbrand WE, et al. Nonsurgical closure of patent ductus PDA occluder system. Circulation 1987;75:583-592.
    • (1987) Circulation , vol.75 , pp. 583-592
    • Rashkind, W.J.1    Mullins, C.E.2    Hellenbrand, W.E.3
  • 7
    • 0004973734 scopus 로고
    • Occlusion of a patent ductus arteriosus in piglet by a double disk self-adjustable device
    • abstract
    • Sideris EB, Sideris SE, Ehly RL. Occlusion of a patent ductus arteriosus in piglet by a double disk self-adjustable device. (abstract) J Am Coll Cardiol 1990;15:240A.
    • (1990) J Am Coll Cardiol , vol.15
    • Sideris, E.B.1    Sideris, S.E.2    Ehly, R.L.3
  • 8
    • 0025857557 scopus 로고
    • Transcatheter closure of patent ductus arteriosus with buttoned device: First successful clinical application in a child
    • Rao PS, Wilson AD, Sideris EB, et al. Transcatheter closure of patent ductus arteriosus with buttoned device: First successful clinical application in a child. Am Heart J 1991;121:1799-1802.
    • (1991) Am Heart J , vol.121 , pp. 1799-1802
    • Rao, P.S.1    Wilson, A.D.2    Sideris, E.B.3
  • 9
    • 0028101950 scopus 로고
    • Transcatheter occlusion of patent ductus arteriosus by Rashkind umbrella device: Follow-up results
    • Arora R, Kalra GS, Nigam M, et al. Transcatheter occlusion of patent ductus arteriosus by Rashkind umbrella device: Follow-up results. Am Heart J 1994;128:539-541.
    • (1994) Am Heart J , vol.128 , pp. 539-541
    • Arora, R.1    Kalra, G.S.2    Nigam, M.3
  • 11
    • 0032748124 scopus 로고    scopus 로고
    • Subclinical aortic perforation with infant double-button patent ductus arteriosus occluder
    • Wilson NJ, Occleshaw CJ, O'Donnel CP, et al. Subclinical aortic perforation with infant double-button patent ductus arteriosus occluder. Cathet Cardiovasc Intervent 1999;48:296-298.
    • (1999) Cathet Cardiovasc Intervent , vol.48 , pp. 296-298
    • Wilson, N.J.1    Occleshaw, C.J.2    O'Donnel, C.P.3
  • 12
    • 0018426729 scopus 로고
    • "Mini" Gianturco stainless steel coils for transcatheter vascular occlusion
    • Anderson JH, Wallace S, Gianturco C, et al. "Mini" Gianturco stainless steel coils for transcatheter vascular occlusion. Radiology 1979;132:301-303.
    • (1979) Radiology , vol.132 , pp. 301-303
    • Anderson, J.H.1    Wallace, S.2    Gianturco, C.3
  • 13
    • 0026551445 scopus 로고
    • Percutaneous closure of small (<2.5 mm) patent ductus arteriosus using coil embolization
    • Cambier PA, Kirby WC, Morre JW, et al. Percutaneous closure of small (<2.5 mm) patent ductus arteriosus using coil embolization. J Am Coll Cardiol 1992;9:815-816.
    • (1992) J Am Coll Cardiol , vol.9 , pp. 815-816
    • Cambier, P.A.1    Kirby, W.C.2    Morre, J.W.3
  • 14
    • 17444447441 scopus 로고    scopus 로고
    • Closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results
    • Masura J, Walsh KP, Thanopoulous B, et al. Closure of moderate-to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results. J Am Coll Cardiol 1998;31:878-82.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 878-882
    • Masura, J.1    Walsh, K.P.2    Thanopoulous, B.3
  • 15
    • 0028281488 scopus 로고
    • Percutaneous closure of small patent ductus arteriosus using occluding spring coils
    • Moore JW, George L, Kirkpatrick SE, et al. Percutaneous closure of small patent ductus arteriosus using occluding spring coils. J Am Coll Cardiol 1994;23:759-765.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 759-765
    • Moore, J.W.1    George, L.2    Kirkpatrick, S.E.3
  • 16
    • 0033133414 scopus 로고    scopus 로고
    • The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: Immediate and intermediate results
    • Ing FF, Sommer RJ. The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: Immediate and intermediate results. J Am Coll Cardiol 1999;33:1710-1718.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1710-1718
    • Ing, F.F.1    Sommer, R.J.2
  • 17
    • 0028785424 scopus 로고
    • Transcatheter embolization coil closure of patent ductus arteriosus-modified delivery for enhanced control during coil positioning
    • Kuhn MA, Latson LA. Transcatheter embolization coil closure of patent ductus arteriosus-modified delivery for enhanced control during coil positioning. Cathet Cardiovasc Diagn 1995;36:288-290.
    • (1995) Cathet Cardiovasc Diagn , vol.36 , pp. 288-290
    • Kuhn, M.A.1    Latson, L.A.2
  • 18
    • 0030049925 scopus 로고    scopus 로고
    • New forceps delivery technique for coil occlusion of patent ductus arteriosus
    • Hays MD, Hoyer MH, Glasow PF. New forceps delivery technique for coil occlusion of patent ductus arteriosus. Am J Cardiol 1996;77:209-211.
    • (1996) Am J Cardiol , vol.77 , pp. 209-211
    • Hays, M.D.1    Hoyer, M.H.2    Glasow, P.F.3
  • 19
    • 0029683983 scopus 로고    scopus 로고
    • Transcatheter occlusion of patent ductus arteriosus in a Newfoundland puppy using the Gianturco-Grifka vascular occlusion device
    • Grifka RG, Miller MW, Frischmeyaer KJ, et al. Transcatheter occlusion of patent ductus arteriosus in a Newfoundland puppy using the Gianturco-Grifka vascular occlusion device. J Vet Intern Med 1996;10:42-44.
    • (1996) J Vet Intern Med , vol.10 , pp. 42-44
    • Grifka, R.G.1    Miller, M.W.2    Frischmeyaer, K.J.3
  • 21
    • 0034909090 scopus 로고    scopus 로고
    • Experimental evaluation of a modified Amplatzer duct occluder
    • Kong H, Gu X, Bass JL, et al. Experimental evaluation of a modified Amplatzer duct occluder. Cathet Cardiovasc Intervent 2001;53:571-576.
    • (2001) Cathet Cardiovasc Intervent , vol.53 , pp. 571-576
    • Kong, H.1    Gu, X.2    Bass, J.L.3
  • 22
    • 0035106006 scopus 로고    scopus 로고
    • Transcatheter PDA closure: Equipment and technique
    • Grifka RG. Transcatheter PDA closure: Equipment and technique. J Interven Cardiol 2002;14:97-107.
    • (2002) J Interven Cardiol , vol.14 , pp. 97-107
    • Grifka, R.G.1
  • 23
    • 0035005006 scopus 로고    scopus 로고
    • Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients
    • Galal MO, Bulbul Z, Kakadekar A, et al. Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients. J Interven Cardiol 2001;14:169-178.
    • (2001) J Interven Cardiol , vol.14 , pp. 169-178
    • Galal, M.O.1    Bulbul, Z.2    Kakadekar, A.3
  • 24
    • 0030627722 scopus 로고    scopus 로고
    • Transcatheter coil occlusion of persistent ductus arteriosus using detachable steel coils: Short term results
    • Arora R, Verma PK, Trehan V, et al. Transcatheter coil occlusion of persistent ductus arteriosus using detachable steel coils: Short term results. Indian Heart J 1997;49:60-64.
    • (1997) Indian Heart J , vol.49 , pp. 60-64
    • Arora, R.1    Verma, P.K.2    Trehan, V.3
  • 25
    • 0036158498 scopus 로고    scopus 로고
    • Severe intravascular hemolysis after transcatheter closure of a large patent ductus arteriosus using Amplatzer duct occluder: Successful resolution by intradevice coil deployment
    • Joseph G, Mandalay A, Zacharias TU, et al. Severe intravascular hemolysis after transcatheter closure of a large patent ductus arteriosus using Amplatzer duct occluder: Successful resolution by intradevice coil deployment. Cathet Cardiovasc Intervent 2002;55:245-249.
    • (2002) Cathet Cardiovasc Intervent , vol.55 , pp. 245-249
    • Joseph, G.1    Mandalay, A.2    Zacharias, T.U.3
  • 26
    • 0032775456 scopus 로고    scopus 로고
    • Long term outcome of transcatheter coil closure of small to large patent ductus arteriosus
    • Patel HT, Cao Q, Rhodes J, et al. Long term outcome of transcatheter coil closure of small to large patent ductus arteriosus. Cathet Cardiovasc Intervent 1999;47:457-61.
    • (1999) Cathet Cardiovasc Intervent , vol.47 , pp. 457-461
    • Patel, H.T.1    Cao, Q.2    Rhodes, J.3
  • 27
    • 0031966571 scopus 로고    scopus 로고
    • Reopening after successful coil occlusion of patent ductus arteriosus
    • Daniels C, Cassidy SC, Teske DW, et al. Reopening after successful coil occlusion of patent ductus arteriosus. J Am Coll Cardiol 1998;31:444-450.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 444-450
    • Daniels, C.1    Cassidy, S.C.2    Teske, D.W.3
  • 28
    • 0012314964 scopus 로고    scopus 로고
    • Transcatheter PDA closure using the Gianturco-Grifka vascular occlusion device
    • Grifka RG. Transcatheter PDA closure using the Gianturco-Grifka vascular occlusion device. Curr Interv Cardiol Rep 2001;3:174-182.
    • (2001) Curr Interv Cardiol Rep , vol.3 , pp. 174-182
    • Grifka, R.G.1
  • 29
    • 0035283024 scopus 로고    scopus 로고
    • Gianturco-Grifka vascular occlusion device for closure of patent ductus arteriosus
    • Ebeid MR, Gaymes CH, Smith JC, et al. Gianturco-Grifka vascular occlusion device for closure of patent ductus arteriosus. Am J Cardiol 2001;87:657-60.
    • (2001) Am J Cardiol , vol.87 , pp. 657-660
    • Ebeid, M.R.1    Gaymes, C.H.2    Smith, J.C.3
  • 30
    • 0035002123 scopus 로고    scopus 로고
    • The Duct-Occlud device: Design, clinical results, and future directions
    • Moore JH, Schneider DJ, Dimeglio D. The Duct-Occlud device: Design, clinical results, and future directions. J Interven Cardiol 2001;14:231-238.
    • (2001) J Interven Cardiol , vol.14 , pp. 231-238
    • Moore, J.H.1    Schneider, D.J.2    Dimeglio, D.3
  • 32
    • 0035152380 scopus 로고    scopus 로고
    • Results of the phase I Food and Drug Administration clinical trial of Duct-Occlud device occlusion of patent ductus arteriosus
    • Moore JW, DiMeglio D, Javois AP, et al. Results of the phase I Food and Drug Administration clinical trial of Duct-Occlud device occlusion of patent ductus arteriosus. Cathet Cardiovasc Intervent 2001;52:74-78.
    • (2001) Cathet Cardiovasc Intervent , vol.52 , pp. 74-78
    • Moore, J.W.1    DiMeglio, D.2    Javois, A.P.3
  • 33
    • 0033101844 scopus 로고    scopus 로고
    • Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device
    • Rao S, Kim SH, Choi JY, et al. Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device. J Am Coll Cardiol 1999;33:820-826.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 820-826
    • Rao, S.1    Kim, S.H.2    Choi, J.Y.3
  • 34
    • 0035022606 scopus 로고    scopus 로고
    • The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus
    • Sideris EB, Rao PS, Zamora R. The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus. J Interven Cardiol 2001;14:239-246.
    • (2001) J Interven Cardiol , vol.14 , pp. 239-246
    • Sideris, E.B.1    Rao, P.S.2    Zamora, R.3
  • 35
    • 0035020995 scopus 로고    scopus 로고
    • Patent ductus arteriosus equipment and technique. Amplatzer duct occluder: Intermediate-term follow-up and technical considerations
    • Thanopoulos BD, Hakim FA, Hirari A, et al. Patent ductus arteriosus equipment and technique. Amplatzer duct occluder: Intermediate-term follow-up and technical considerations. J Interven Cardiol 2001;14:247-254.
    • (2001) J Interven Cardiol , vol.14 , pp. 247-254
    • Thanopoulos, B.D.1    Hakim, F.A.2    Hirari, A.3
  • 36
    • 0033857330 scopus 로고    scopus 로고
    • Closure of patent ductus arteriosus with Amplatzer PDA device: Immediate results of the international clinical trial
    • Faella HJ, Hijaji ZM. Closure of patent ductus arteriosus with Amplatzer PDA device: Immediate results of the international clinical trial. Cathet Cardiovasc Intervent 2000;51:50-54.
    • (2000) Cathet Cardiovasc Intervent , vol.51 , pp. 50-54
    • Faella, H.J.1    Hijaji, Z.M.2
  • 37
    • 0035165596 scopus 로고    scopus 로고
    • The Amplatzer duct occluder: Experience in 209 patients
    • Bilkis AA, Alwi M, Hasri S, et al. The Amplatzer duct occluder: Experience in 209 patients. J Am Coll Cardiol 2001;37:258-261.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 258-261
    • Bilkis, A.A.1    Alwi, M.2    Hasri, S.3
  • 38
    • 0033022135 scopus 로고    scopus 로고
    • Aortic obstruction caused by device occlusion of patent arterial duct
    • Duke C, Chan KC. Aortic obstruction caused by device occlusion of patent arterial duct. Heart 1999;82:109-111.
    • (1999) Heart , vol.82 , pp. 109-111
    • Duke, C.1    Chan, K.C.2
  • 39
    • 0034821345 scopus 로고    scopus 로고
    • Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder
    • Fischer G, Uebing A, Grabitz R, et al. Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder. Heart 2001;86:444-447.
    • (2001) Heart , vol.86 , pp. 444-447
    • Fischer, G.1    Uebing, A.2    Grabitz, R.3
  • 40
    • 0036181224 scopus 로고    scopus 로고
    • Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder
    • Thanopoulos BD, Tsaousis GS, Djukic M, et al. Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder. Heart 2002;87:260-263.
    • (2002) Heart , vol.87 , pp. 260-263
    • Thanopoulos, B.D.1    Tsaousis, G.S.2    Djukic, M.3
  • 41
    • 0035123895 scopus 로고    scopus 로고
    • Transcatheter closure of a 16 mm hypertensive patent ductus arteriosus with the Amplatzer muscular VSD occluder
    • Demkow M, Ruzyllo W, Siudalska H, et al. Transcatheter closure of a 16 mm hypertensive patent ductus arteriosus with the Amplatzer muscular VSD occluder. Cathet Cardiovasc Intervent 2001;52:359-362.
    • (2001) Cathet Cardiovasc Intervent , vol.52 , pp. 359-362
    • Demkow, M.1    Ruzyllo, W.2    Siudalska, H.3
  • 42
    • 0035022068 scopus 로고    scopus 로고
    • Patent ductus arteriosus: Catheter closure in the adult patient
    • Arora R, Singh S, Kalra GS. Patent ductus arteriosus: Catheter closure in the adult patient. J Interven Cardiol 2001;14:255-259.
    • (2001) J Interven Cardiol , vol.14 , pp. 255-259
    • Arora, R.1    Singh, S.2    Kalra, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.