메뉴 건너뛰기




Volumn 123, Issue 4, 2001, Pages 914-919

Modified general equation for the design of capillary tubes

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0142148431     PISSN: 00982202     EISSN: 1528901X     Source Type: Journal    
DOI: 10.1115/1.1411970     Document Type: Article
Times cited : (21)

References (19)
  • 1
    • 0012650790 scopus 로고
    • American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta
    • ASHRAE, 1988, ASHRAE Handbook-1988 Equipment, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, pp. 1921-1930.
    • (1988) ASHRAE Handbook-1988 Equipment , pp. 1921-1930
  • 2
    • 0025725444 scopus 로고
    • Modeling of Steady Flows of R-22 through Capillary Tubes
    • Kuehl, S. J., and Goldschmidt, V. W., 1991, “Modeling of Steady Flows of R-22 through Capillary Tubes,” ASHRAE Trans., 97, Part 1, pp. 139-148.
    • (1991) ASHRAE Trans , vol.97 , pp. 139-148
    • Kuehl, S.J.1    Goldschmidt, V.W.2
  • 3
    • 0000192079 scopus 로고
    • Numerical Modeling of Thermodynamic Non-Equilibrium Flow of Refrigerant through Capillary Tubes
    • Li, R. Y., Lin, S., and Chen, Z. H., 1990, “Numerical Modeling of Thermodynamic Non-Equilibrium Flow of Refrigerant through Capillary Tubes,” ASHRAE Trans., 96, Part 1, pp. 542-549.
    • (1990) ASHRAE Trans , vol.96 , pp. 542-549
    • Li, R.Y.1    Lin, S.2    Chen, Z.H.3
  • 4
    • 0029250905 scopus 로고
    • Numerical Simulation of Capillary-Tube Expansion Devices
    • Escanes, F., Perez-Segarra, C. D., and Oliva, A., 1995, “Numerical Simulation of Capillary-Tube Expansion Devices,” Int. J. Refrig., 18, pp. 113-122.
    • (1995) Int. J. Refrig , vol.18 , pp. 113-122
    • Escanes, F.1    Perez-Segarra, C.D.2    Oliva, A.3
  • 5
    • 0030312032 scopus 로고    scopus 로고
    • A Theoretical Model for Predicting Adiabatic Capillary Tube Performance with Alternative Refrigerants
    • Bittle, R. R., and Pate, M. B., 1996, “A Theoretical Model for Predicting Adiabatic Capillary Tube Performance with Alternative Refrigerants,” ASHRAE Trans., 102, Part 2, pp. 52-64.
    • (1996) ASHRAE Trans , vol.102 , pp. 52-64
    • Bittle, R.R.1    Pate, M.B.2
  • 6
    • 0032320822 scopus 로고    scopus 로고
    • A Numerical Procedure for Simulation of Fanno Flows of Refrigerants or Refrigerant Mixtures in Capillary Tubes
    • Chung, M., 1998, “A Numerical Procedure for Simulation of Fanno Flows of Refrigerants or Refrigerant Mixtures in Capillary Tubes,” ASHRAE Trans., 104, Part 2, pp. 1031-1042.
    • (1998) ASHRAE Trans , vol.104 , pp. 1031-1042
    • Chung, M.1
  • 7
    • 0032090223 scopus 로고    scopus 로고
    • Numerical Prediction of Capillary Tube Behavior with Pure and Binary Alternative Refrigerants
    • Sami, S. M., and Tribes, C., 1998, “Numerical Prediction of Capillary Tube Behavior with Pure and Binary Alternative Refrigerants,” Appl. Therm. Eng., 18, pp. 491-502.
    • (1998) Appl. Therm. Eng , vol.18 , pp. 491-502
    • Sami, S.M.1    Tribes, C.2
  • 8
    • 0033334642 scopus 로고    scopus 로고
    • Capillary Tube Selection for HCFC22 Alternatives
    • Jung, D., Park, C., and Park, B., 1999, “Capillary Tube Selection for HCFC22 Alternatives,” Int. J. Refrig., 22, pp. 604-614.
    • (1999) Int. J. Refrig , vol.22 , pp. 604-614
    • Jung, D.1    Park, C.2    Park, B.3
  • 9
    • 0030288386 scopus 로고    scopus 로고
    • An Empirical Correlation for Sizing Capillary Tubes
    • Bansal, P. K., and Rupasinghe, A. S., 1996, “An Empirical Correlation for Sizing Capillary Tubes,” Int. J. Refrig., 19, pp. 497-505.
    • (1996) Int. J. Refrig , vol.19 , pp. 497-505
    • Bansal, P.K.1    Rupasinghe, A.S.2
  • 10
    • 0031699375 scopus 로고    scopus 로고
    • A Generalized Performance Prediction Method for Adiabatic Capillary Tubes
    • Bittle, R. R., Wolf, D. A., and Pate, M. B., 1998, “A Generalized Performance Prediction Method for Adiabatic Capillary Tubes,” HVAC&R Research, 4, pp. 27-43.
    • (1998) Hvac&R Research , vol.4 , pp. 27-43
    • Bittle, R.R.1    Wolf, D.A.2    Pate, M.B.3
  • 11
    • 0033343890 scopus 로고    scopus 로고
    • On the Development of Rating Correlations for R134a Flowing through Adiabatic Capillary Tubes
    • Chen, S. L., Liu, C. H., and Jwo, C. S., 1999, “On the Development of Rating Correlations for R134a Flowing through Adiabatic Capillary Tubes,” ASHRAE Trans., 105, Part 2, pp. 75-86.
    • (1999) ASHRAE Trans , vol.105 , pp. 75-86
    • Chen, S.L.1    Liu, C.H.2    Jwo, C.S.3
  • 13
    • 0030108061 scopus 로고    scopus 로고
    • General Equation for the Design of Capillary Tubes
    • Yilmaz, T., and Ünal, S., 1996, “General Equation for the Design of Capillary Tubes,” ASME J. Fluids Eng., 118, pp. 150-154.
    • (1996) ASME J. Fluids Eng , vol.118 , pp. 150-154
    • Yilmaz, T.1    Ünal, S.2
  • 15
    • 0017769439 scopus 로고
    • Frictional Equation Spans All Fluid Flow Regions
    • Churchill, S. W., 1977, “Frictional Equation Spans All Fluid Flow Regions,” Chem. Eng., 84, No. 24, pp. 91-92.
    • (1977) Chem. Eng , vol.84 , Issue.24 , pp. 91-92
    • Churchill, S.W.1
  • 16
  • 17
    • 85146288812 scopus 로고
    • Vaporization inside Horizontal Tubes-II-Benzene-Oil Mixtures
    • McAdams, W. H., Wood, W. K., and Bryan, R. L., 1942, “Vaporization inside Horizontal Tubes-II-Benzene-Oil Mixtures,” Trans. ASME, 64, pp. 193.
    • (1942) Trans. ASME , vol.64 , pp. 193
    • McAdams, W.H.1    Wood, W.K.2    Bryan, R.L.3
  • 18
    • 84984087411 scopus 로고
    • Frictional Pressure Drop in Two-Phase Flow-Part A and B
    • Dukler, A. E., Wicks, M., and Cleveland, R. G., 1964, “Frictional Pressure Drop in Two-Phase Flow-Part A and B,” AIChE J., 10, No. 1, pp. 38-51.
    • (1964) Aiche J , vol.10 , Issue.1 , pp. 38-51
    • Dukler, A.E.1    Wicks, M.2    Cleveland, R.G.3
  • 19
    • 0002914921 scopus 로고
    • Adiabatic Capillary Tube Test Data for HFC-134a
    • West Lafayette, Ind
    • Wijaya, H., 1992, “Adiabatic Capillary Tube Test Data for HFC-134a,” Proc. The IIR-Purdue Refrigeration Conference, West Lafayette, Ind., Vol. 1, pp. 63-71.
    • (1992) Proc. The Iir-Purdue Refrigeration Conference , vol.1 , pp. 63-71
    • Wijaya, H.1