메뉴 건너뛰기




Volumn 2, Issue , 2002, Pages 699-703

Front-end Electronics Based on High-yield-pileup-event-recovery Method for a High Resolution PET Camera with PMT-quadrant-sharing Detector Modules

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CAMERAS; IMAGE RECONSTRUCTION; LIGHT EMITTING DIODES; PROBLEM SOLVING; QUALITY CONTROL;

EID: 0142148132     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (10)
  • 1
    • 0036815778 scopus 로고    scopus 로고
    • The design of a high resolution transformable whole body PET camera
    • October
    • W.H. Wong, "The design of a high resolution transformable whole body PET camera," IEEE Trans. Nucl. Sci., vol. 49(5), October, 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5
    • Wong, W.H.1
  • 2
    • 0030170247 scopus 로고    scopus 로고
    • Design of a variable field prototype PET camera
    • June
    • W.H. Wong, J. Uribe, W. Liu, K. Hicks, "Design of a variable field prototype PET camera," IEEE Trans. Nucl. Sci., vol. 43 pp. 1915-1920, June 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 1915-1920
    • Wong, W.H.1    Uribe, J.2    Liu, W.3    Hicks, K.4
  • 3
    • 0033355614 scopus 로고    scopus 로고
    • Prototype electronics for a variable field of view PET camera using the PMT-quadrant-sharing detector array
    • June
    • H. Li, W.H. Wong, N. Zhang, J. Wang, J. Uribe, H. Baghaei, S. Yokoyama, "Prototype electronics for a variable field of view PET camera using the PMT-Quadrant-Sharing detector array," IEEE Trans. Nucl. Sci., vol. 46, pp. 546-550, June 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 546-550
    • Li, H.1    Wong, W.H.2    Zhang, N.3    Wang, J.4    Uribe, J.5    Baghaei, H.6    Yokoyama, S.7
  • 4
    • 0035043959 scopus 로고    scopus 로고
    • Feasibility study of a high speed gamma camera design using the high-yield-pileup-event-recovery (HYPER) method
    • April
    • W.H. Wong, H. Li, J. Uribe, H. Baghaei, Y. Wang, S. Yokoyams, "Feasibility study of a high speed gamma camera design using the high-yield-pileup-event-recovery (HYPER) method," The Journal of Nuclear Medicine, vol.42, no. 4, April 2001.
    • (2001) The Journal of Nuclear Medicine , vol.42 , Issue.4
    • Wong, W.H.1    Li, H.2    Uribe, J.3    Baghaei, H.4    Wang, Y.5    Yokoyams, S.6
  • 5
    • 0142241231 scopus 로고    scopus 로고
    • Signal characteristics of individual crystals in a high resolution BGO detector design using PMT-quadrant-sharing
    • J.Uribe, W.H. Wong, et al, "Signal characteristics of individual crystals in a high resolution BGO detector design using PMT-Quadrant-Sharing", Conference record of the 2002 IEEE MIC Conference.
    • (2000) Conference Record of the 2002 IEEE MIC Conference
    • Uribe, J.1    Wong, W.H.2
  • 6
    • 0036816137 scopus 로고    scopus 로고
    • A new pileup-prevention front-end electronics design for high resolution PET and gamma cameras
    • October
    • H. Li, W.H. Wong, et al, "A new pileup-prevention front-end electronics design for high resolution PET and gamma cameras," IEEE Trans. Nucl. Sci., vol. 49(5), October 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5
    • Li, H.1    Wong, W.H.2
  • 7
    • 0142205463 scopus 로고    scopus 로고
    • A modular low dead-time coincidence system for high resolution PET cameras
    • Y. Wang, et al, "A modular low dead-time coincidence system for high resolution PET cameras," Conference record of the 2002 IEEE MIC Conference.
    • (2000) Conference Record of the 2002 IEEE MIC Conference
    • Wang, Y.1
  • 8
    • 0032995626 scopus 로고    scopus 로고
    • Changes in the energy response of a dedicated gamma camera after exposure to a high-flux irradiation
    • Matheoud R, Zito F, Canz C, Voltini F, Gerundini P. "Changes in the energy response of a dedicated gamma camera after exposure to a high-flux irradiation," Phys. Med. Biol., 44, N129-N135, 1999.
    • (1999) Phys. Med. Biol. , vol.44
    • Matheoud, R.1    Zito, F.2    Canz, C.3    Voltini, F.4    Gerundini, P.5
  • 9
    • 0035554561 scopus 로고    scopus 로고
    • Effect of photomultiplier gain-drift and radiation exposure on 2D-map decoding of detector arrays used in positron emission tomography
    • J. Uribe, et al, "Effect of photomultiplier gain-drift and radiation exposure on 2D-map decoding of detector arrays used in positron emission tomography." Conference record of the 2001 IEEE MIC Conference.
    • (2001) Conference Record of the 2001 IEEE MIC Conference
    • Uribe, J.1
  • 10
    • 0142179088 scopus 로고    scopus 로고
    • A HOTLink/networked PC data acquisition and image reconstruction system for a high resolution whole-body PET with respiratory or ECG gated performance
    • H. Li. T. Xing, et al, "A HOTLink/networked PC data acquisition and image reconstruction system for a high resolution whole-body PET with respiratory or ECG gated performance," Conference record of the 2002 IEEE MIC Conference.
    • (2002) Conference Record of the 2002 IEEE MIC Conference
    • Li, H.1    Xing, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.