메뉴 건너뛰기




Volumn 3, Issue , 2002, Pages 1481-1485

Anatomical Based FDG-PET Reconstruction for the Detection of Hypometabolic Regions in Epilepsy

Author keywords

Anatomical prior information; Epilepsy; Iterative reconstruction algorithm; Positron emission tomography

Indexed keywords

ALGORITHMS; ITERATIVE METHODS; MEDICAL IMAGING; POSITRON EMISSION TOMOGRAPHY; SIGNAL TO NOISE RATIO;

EID: 0142148047     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (6)
  • 1
    • 0033201366 scopus 로고    scopus 로고
    • Automated model-based tissue classification of MR images of the brain
    • Oct.
    • K. Van Leemput, F. Maes, D. Vandermeulen, and P. Suetens," Automated model-based tissue classification of MR images of the brain," IEEE Trans. Med. Imag., vol. 18, No. 10, pp. 897-908, Oct. 1999.
    • (1999) IEEE Trans. Med. Imag. , vol.18 , Issue.10 , pp. 897-908
    • Van Leemput, K.1    Maes, F.2    Vandermeulen, D.3    Suetens, P.4
  • 2
    • 0031283380 scopus 로고    scopus 로고
    • Multimodality bayesian algorithm for image reconstruction in positron emission tomography: A tissue composition model
    • Dec.
    • S. Sastry, and R.E. Carson," Multimodality bayesian algorithm for image reconstruction in positron emission tomography: a tissue composition model," IEEE Trans. Med. Imag., vol. 16, No. 6, pp. 750-761, Dec. 1997.
    • (1997) IEEE Trans. Med. Imag. , vol.16 , Issue.6 , pp. 750-761
    • Sastry, S.1    Carson, R.E.2
  • 3
    • 0031106962 scopus 로고    scopus 로고
    • Multimodality image registration by maximization of mutual information
    • Apr.
    • F. Maes, A. Collignon, D. Vandermeulen, G. Marchal and P. Suetens," Multimodality image registration by maximization of mutual information," IEEE Trans. Med. Imag., vol. 16, no. 2, pp. 187-198, Apr. 1997.
    • (1997) IEEE Trans. Med. Imag. , vol.16 , Issue.2 , pp. 187-198
    • Maes, F.1    Collignon, A.2    Vandermeulen, D.3    Marchal, G.4    Suetens, P.5
  • 4
    • 0036464522 scopus 로고    scopus 로고
    • A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomography
    • Feb.
    • J. Nuyts, D. Bequé, P. Dupont and L. Mortelmans," A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomography," IEEE Trans. Nucl. Sci., vol. 49, No. 1, pp. 56-60, Feb. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.1 , pp. 56-60
    • Nuyts, J.1    Bequé, D.2    Dupont, P.3    Mortelmans, L.4
  • 5
    • 0142205295 scopus 로고    scopus 로고
    • http://www.bic.mni.mcgill.ca/brainweb