메뉴 건너뛰기




Volumn 3, Issue , 2002, Pages 1597-1601

Transmission Imaging with a Compact Gamma Camera: Initial Results for Mammotomography

Author keywords

[No Author keywords available]

Indexed keywords

CAMERAS; MEDICAL IMAGING; X RAYS;

EID: 0142148014     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 1
    • 0001800886 scopus 로고    scopus 로고
    • Dedicated Breast Imaging with an ASET: Application Specific Emission Tomograph
    • MP Tornai, JE Bowsher, CN Archer, et al. 2001. Dedicated Breast Imaging with an ASET: Application Specific Emission Tomograph. J. Nucl. Med. 42(5):97P.
    • (2001) J. Nucl. Med. , vol.42 , Issue.5
    • Tornai, M.P.1    Bowsher, J.E.2    Archer, C.N.3
  • 2
    • 0037457873 scopus 로고    scopus 로고
    • A 3D Gantry Single Photon Emission Tomograph with Hemispherical Coverage for Dedicated Breast Imaging
    • In press
    • MP Tornai, JE Bowsher, CN Archer, et al. 2002. A 3D Gantry Single Photon Emission Tomograph with Hemispherical Coverage for Dedicated Breast Imaging." Nucl. Instr. Meth. Phys. Res. A (In press).
    • (2002) Nucl. Instr. Meth. Phys. Res. A
    • Tornai, M.P.1    Bowsher, J.E.2    Archer, C.N.3
  • 4
    • 0142236180 scopus 로고    scopus 로고
    • A Compact Dedicated Device for Dual Modality Radionuclide Imaging of the Breast with an Application Specific Emission and Transmission Tomograph (ASETT)
    • MP Tornai, JE Bowsher, CN Archer, et al. 2001. A Compact Dedicated Device for Dual Modality Radionuclide Imaging of the Breast with an Application Specific Emission and Transmission Tomograph (ASETT). Radiology, 221P:555.
    • (2001) Radiology , vol.221 P , pp. 555
    • Tornai, M.P.1    Bowsher, J.E.2    Archer, C.N.3
  • 5
    • 0142174116 scopus 로고    scopus 로고
    • Feasibility of Application Specific Emission and Transmission Tomography (ASETT) of the Breast
    • MP Tornai, JE Bowsher, CN Archer, RJ Jaszczak. 2002. Feasibility of Application Specific Emission and Transmission Tomography (ASETT) of the Breast. J. Nucl. Med. 43(5):12P.
    • (2002) J. Nucl. Med. , vol.43 , Issue.5 , pp. 12
    • Tornai, M.P.1    Bowsher, J.E.2    Archer, C.N.3    Jaszczak, R.J.4
  • 6
    • 17944370497 scopus 로고    scopus 로고
    • Development of a quasi-monochromatic CT system for breast cancer study with combined emission-transmission tomography
    • M. Gambaccini, A Fantini, et al. 2001. Development of a quasi-monochromatic CT system for breast cancer study with combined emission-transmission tomography. IEEE Trans Nucl Sci. NS48(2):703-706.
    • (2001) IEEE Trans Nucl Sci. , vol.NS48 , Issue.2 , pp. 703-706
    • Gambaccini, M.1    Fantini, A.2
  • 7
    • 0001820951 scopus 로고    scopus 로고
    • LumaGEM: High-Resolution Dedicated Gamma Camera
    • LR MacDonald, BE Patt, JS Iwanczyk, et al. 2000. LumaGEM: High-Resolution Dedicated Gamma Camera. J Nucl Med. 41(5):56P.
    • (2000) J Nucl Med. , vol.41 , Issue.5 , pp. 56
    • Macdonald, L.R.1    Patt, B.E.2    Iwanczyk, J.S.3
  • 8
    • 0034467767 scopus 로고    scopus 로고
    • Evaluation of Performance of Dedicated, Compact Scintillation Cameras
    • DP McElroy, EJ Hoffman, LR MacDonald, et al. 2000. Evaluation of Performance of Dedicated, Compact Scintillation Cameras. Proc. SPIE. 4142:231-241.
    • (2000) Proc. SPIE. , vol.4142 , pp. 231-241
    • McElroy, D.P.1    Hoffman, E.J.2    Macdonald, L.R.3
  • 9
    • 0030026377 scopus 로고    scopus 로고
    • Transmission imaging of large attenuators using a slant hole collimator on a three-headed SPECT system
    • MA King, D Luo, ST Dahlberg, et al. 1996. Transmission imaging of large attenuators using a slant hole collimator on a three-headed SPECT system. Med. Phys. 23:263-272.
    • (1996) Med. Phys. , vol.23 , pp. 263-272
    • King, M.A.1    Luo, D.2    Dahlberg, S.T.3
  • 10
    • 0029040704 scopus 로고
    • Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation
    • DJ Kadramas, RJ Jaszczak, JW McCormick, et al. 1995. Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation. Phys. Med. Biol. 40:1085-1104.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1085-1104
    • Kadramas, D.J.1    Jaszczak, R.J.2    McCormick, J.W.3
  • 11
    • 0034207024 scopus 로고    scopus 로고
    • Investigation of Large Field-of-View Transmission Imaging for SPECT Attenuation Compensation with Gd-153, Tc-99m and Ce-139 Sources
    • MP Tomai, RJ Jaszczak, DR Gilland, et al. 2000. "Investigation of Large Field-of-View Transmission Imaging for SPECT Attenuation Compensation with Gd-153, Tc-99m and Ce-139 Sources." IEEE Trans. Nucl. Sci. NS47(3):1182-1191.
    • (2000) IEEE Trans. Nucl. Sci. , vol.NS47 , Issue.3 , pp. 1182-1191
    • Tomai, M.P.1    Jaszczak, R.J.2    Gilland, D.R.3
  • 12
    • 0029020079 scopus 로고
    • Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT
    • SH Manglos, GM Gagne, A Krol, et al. 1995. Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT. Phys Med Biol, 40:1225-1241.
    • (1995) Phys Med Biol , vol.40 , pp. 1225-1241
    • Manglos, S.H.1    Gagne, G.M.2    Krol, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.