메뉴 건너뛰기




Volumn 6, Issue 4, 2003, Pages 258-269

Fascicular selectivity in transverse stimulation with a nerve cuff electrode: A theoretical approach

Author keywords

Computer modeling; Multifascicular nerve; Nerve cuff electrode; Nerve stimulation; Spatial selectivity

Indexed keywords

ANIMAL TISSUE; ARTICLE; COMPUTER MODEL; CONTROLLED STUDY; ELECTRIC CURRENT; ELECTRODE; FIBER; MOTOR NERVE; MYELINATED NERVE; NERVE CUFF ELECTRODE; NERVE FIBER; NERVE STIMULATION; NONHUMAN; RABBIT; RANVIER NODE; SCIATIC NERVE;

EID: 0142121543     PISSN: 10947159     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1403.2003.03034.x     Document Type: Article
Times cited : (22)

References (29)
  • 2
    • 0025913212 scopus 로고
    • Central course of digital axons within the median nerve of Macaca mulatta
    • Brushart TM. Central course of digital axons within the median nerve of Macaca mulatta. J Comp Neurol 1991;311:197-209.
    • (1991) J Comp Neurol , vol.311 , pp. 197-209
    • Brushart, T.M.1
  • 3
    • 0002294920 scopus 로고
    • Overview of peripheral nerve electrode design and implantation
    • Prentice Hall: Englewood Cliffs
    • Naples GG, Mortimer JT, Yuen TGH. Overview of peripheral nerve electrode design and implantation. In: Neural Prostheses, Fundamental Studies. Prentice Hall: Englewood Cliffs, 1990:107-145.
    • (1990) Neural Prostheses, Fundamental Studies , pp. 107-145
    • Naples, G.G.1    Mortimer, J.T.2    Yuen, T.G.H.3
  • 4
    • 0029325943 scopus 로고
    • Perspectives on new electrode technology for stimulating peripheral nerves with implantable motor prostheses
    • Mortimer JT, Agnew WF, Horch K, Citron P, Creasey G, Kantor C. Perspectives on new electrode technology for stimulating peripheral nerves with implantable motor prostheses. IEEE Trans Rehab Eng 1995;3:45-154.
    • (1995) IEEE Trans Rehab Eng , vol.3 , pp. 45-154
    • Mortimer, J.T.1    Agnew, W.F.2    Horch, K.3    Citron, P.4    Creasey, G.5    Kantor, C.6
  • 6
    • 0027717896 scopus 로고
    • Selective control of muscle activation with a multipolar nerve cuff electrode
    • Veraart C, Grill WM, Mortimer JT. Selective control of muscle activation with a multipolar nerve cuff electrode. IEEE Trans Biomed Eng 1993;40:640-653.
    • (1993) IEEE Trans Biomed Eng , vol.40 , pp. 640-653
    • Veraart, C.1    Grill, W.M.2    Mortimer, J.T.3
  • 7
    • 0030176010 scopus 로고    scopus 로고
    • Quantification of recruitment properties of multiple contact cuff electrodes
    • Grill WM, Mortimer JT. Quantification of recruitment properties of multiple contact cuff electrodes. IEEE Trans Rehab Eng 1996;4:49-62.
    • (1996) IEEE Trans Rehab Eng , vol.4 , pp. 49-62
    • Grill, W.M.1    Mortimer, J.T.2
  • 8
    • 0032374065 scopus 로고    scopus 로고
    • Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes
    • Grill WM, Mortimer JT. Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes. IEEE Trans Rehab Eng 1998;6:364-373.
    • (1998) IEEE Trans Rehab Eng , vol.6 , pp. 364-373
    • Grill, W.M.1    Mortimer, J.T.2
  • 9
    • 0025453330 scopus 로고
    • A nerve cuff technique for selective excitation of peripheral nerve trunk regions
    • Sweeney JD, Ksienski DA, Mortimer JT. A nerve cuff technique for selective excitation of peripheral nerve trunk regions. IEEE Trans Biomed Eng 1990;37:706-715.
    • (1990) IEEE Trans Biomed Eng , vol.37 , pp. 706-715
    • Sweeney, J.D.1    Ksienski, D.A.2    Mortimer, J.T.3
  • 10
    • 0029294523 scopus 로고
    • Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
    • Sweeney JD, Crawford NR, Brandon TA. Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays. Med Biol Eng Comp 1995;33:418-425.
    • (1995) Med Biol Eng Comp , vol.33 , pp. 418-425
    • Sweeney, J.D.1    Crawford, N.R.2    Brandon, T.A.3
  • 11
    • 0030221259 scopus 로고    scopus 로고
    • Positionselective activation of peripheral nerve fibers with a cuff electrode
    • Goodall EV, de Breij F, Holsheimer J. Positionselective activation of peripheral nerve fibers with a cuff electrode. IEEE Trans Biomed Eng 1996;43:851-856.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 851-856
    • Goodall, E.V.1    De Breij, F.2    Holsheimer, J.3
  • 12
    • 0031974646 scopus 로고    scopus 로고
    • Transverse tripolar stimulation of peripheral nerve: A modelling study of spatial selectivity
    • Deurloo KEI, Holsheimer J, Boom HBK. Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity. Med Biol Eng Comp 1998;36:66-74.
    • (1998) Med Biol Eng Comp , vol.36 , pp. 66-74
    • Deurloo, K.E.I.1    Holsheimer, J.2    Boom, H.B.K.3
  • 14
    • 0031293737 scopus 로고    scopus 로고
    • Quantification of similarities in recruitment properties of monopolar and tripolar configurations
    • Tarler MD, Mortimer JT. Quantification of similarities in recruitment properties of monopolar and tripolar configurations. Proc Ann Int Conf IEEE Eng Med Biol Soc 1997;19:2000-2001.
    • (1997) Proc Ann Int Conf IEEE Eng Med Biol Soc , vol.19 , pp. 2000-2001
    • Tarler, M.D.1    Mortimer, J.T.2
  • 15
    • 0030198491 scopus 로고    scopus 로고
    • Transverse tripolar spinal cord stimulation, theoretical performance of a dual channel system
    • Strnijk JJ, Holsheimer J. Transverse tripolar spinal cord stimulation, theoretical performance of a dual channel system. Med Biol Eng Comp 1996;34:273-279.
    • (1996) Med Biol Eng Comp , vol.34 , pp. 273-279
    • Strnijk, J.J.1    Holsheimer, J.2
  • 17
    • 0029378354 scopus 로고
    • Modeling study of activation and propagation delays during stimulation of peripheral nerve fibers with a tripolar cuff electrode
    • Goodall EV, Kosterman LM, Holsheimer J, Struijk JJ. Modeling study of activation and propagation delays during stimulation of peripheral nerve fibers with a tripolar cuff electrode. IEEE Trans Rehab Eng 1995;3:272-282.
    • (1995) IEEE Trans Rehab Eng , vol.3 , pp. 272-282
    • Goodall, E.V.1    Kosterman, L.M.2    Holsheimer, J.3    Struijk, J.J.4
  • 18
    • 0026153583 scopus 로고
    • In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes
    • Suesserman MF, Spelman FA, Rubinstein JT. In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes. IEEE Trans Biomed Eng 1991;38:401-408.
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 401-408
    • Suesserman, M.F.1    Spelman, F.A.2    Rubinstein, J.T.3
  • 19
    • 0017103492 scopus 로고
    • Analysis of a model for excitation of myelinated nerve
    • McNeal DR. Analysis of a model for excitation of myelinated nerve. IEEE Trans Biomed Eng 1976;23:329-337.
    • (1976) IEEE Trans Biomed Eng , vol.23 , pp. 329-337
    • McNeal, D.R.1
  • 20
    • 0018333172 scopus 로고
    • A quantitative description of membrane currents in rabbit myelinated nerve
    • Chiu SY, Ritchie JM, Rogart RB, Stagg D. A quantitative description of membrane currents in rabbit myelinated nerve. J Physiol 1979;292:149-166.
    • (1979) J Physiol , vol.292 , pp. 149-166
    • Chiu, S.Y.1    Ritchie, J.M.2    Rogart, R.B.3    Stagg, D.4
  • 23
    • 0023855458 scopus 로고
    • Axonal conduction velocity and force of single human motor units
    • Dengler R, Stein RB, Thomas CK. Axonal conduction velocity and force of single human motor units. Muscle Nerve 1988;11:136-145.
    • (1988) Muscle Nerve , vol.11 , pp. 136-145
    • Dengler, R.1    Stein, R.B.2    Thomas, C.K.3
  • 26
    • 0031023090 scopus 로고    scopus 로고
    • Inversion of the current-distance relationship by transient depolarization
    • Grill WM, Mortimer JT. Inversion of the current-distance relationship by transient depolarization. IEEE Trans Biomed Eng 1997;44:1-9.
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 1-9
    • Grill, W.M.1    Mortimer, J.T.2
  • 27
    • 0035489503 scopus 로고    scopus 로고
    • The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic Volume conductor model
    • Deurloo KEI, Holsheimer J, Bergveld P. The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic Volume conductor model. Biol Cybernetics 2001;85:281-291.
    • (2001) Biol Cybernetics , vol.85 , pp. 281-291
    • Deurloo, K.E.I.1    Holsheimer, J.2    Bergveld, P.3
  • 28
    • 0028434263 scopus 로고
    • Selective stimulation of sacral nerve roots for bladder control; a study by computer modeling
    • Rijkhoff NJM, Holsheimer J, Koldewijn EL et al. Selective stimulation of sacral nerve roots for bladder control; A study by computer modeling. IEEE Trans Biomed Eng 1994;41:413-424.
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 413-424
    • Rijkhoff, N.J.M.1    Holsheimer, J.2    Koldewijn, E.L.3
  • 29
    • 0022929737 scopus 로고
    • Analysis of models for external stimulation of axons
    • Rattay F. Analysis of models for external stimulation of axons. IEEE Trans Biomed Eng 1986;33:974-977.
    • (1986) IEEE Trans Biomed Eng , vol.33 , pp. 974-977
    • Rattay, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.