Volumn 24, Issue 1, 2004, Pages 29-41

An empirical correlation and rating charts for the performance of adiabatic capillary tubes with alternative refrigerants

Author keywords

Adiabatic capillary tubes; Alternative refrigerants; Empirical correlation; Mass flow rate; Rating charts

Indexed keywords

AIR CONDITIONING; DATABASE SYSTEMS; REFRIGERANTS; REFRIGERATION;

EID: 0142094635     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1359-4311(03)00238-2     Document Type: Article
Times cited : (45)

References (20)
  • 1
    • 0030288386 scopus 로고    scopus 로고
    • An empirical correlation for sizing capillary tubes
    • Bansal P.K., Rupasinghe A.S. An empirical correlation for sizing capillary tubes. Int. J. Refrig. 19(8):1996;497-505.
    • (1996) Int. J. Refrig. , vol.19 , Issue.8 , pp. 497-505
    • Bansal, P.K.1    Rupasinghe, A.S.2
  • 2
    • 0005375717 scopus 로고
    • Theory and use of the capillary tube expansion device; Part II, non-adiabatic flow
    • Bolstad N.M., Jordan R.C. Theory and use of the capillary tube expansion device; Part II, non-adiabatic flow. Refrig. Eng. 57(6):1949;572-583.
    • (1949) Refrig. Eng. , vol.57 , Issue.6 , pp. 572-583
    • Bolstad, N.M.1    Jordan, R.C.2
  • 3
    • 0003656630 scopus 로고
    • Rating the restrictor tube
    • Hopkins N.E. Rating the restrictor tube. Refrig. Eng. 58(11):1950;1087-1095.
    • (1950) Refrig. Eng. , vol.58 , Issue.11 , pp. 1087-1095
    • Hopkins, N.E.1
  • 4
    • 0001827106 scopus 로고
    • Capillary two-phase flow
    • Whitesel H.A. Capillary two-phase flow. Refrig. Eng. 65(9):1957;35-47.
    • (1957) Refrig. Eng. , vol.65 , Issue.9 , pp. 35-47
    • Whitesel, H.A.1
  • 5
    • 0001889709 scopus 로고
    • Adiabatic single and two-phase flow in small bore tubes
    • Milkol E.P. Adiabatic single and two-phase flow in small bore tubes. ASHRAE J. 5(11):1963;75-86.
    • (1963) ASHRAE J. , vol.5 , Issue.11 , pp. 75-86
    • Milkol, E.P.1
  • 6
    • 0002905865 scopus 로고
    • Characteristics of refrigerant flow in a capillary tube
    • Koizumi H., Yokoyama K. Characteristics of refrigerant flow in a capillary tube. ASHRAE Trans. 86(2):1980;19-27.
    • (1980) ASHRAE Trans. , vol.86 , Issue.2 , pp. 19-27
    • Koizumi, H.1    Yokoyama, K.2
  • 7
    • 0025725444 scopus 로고
    • Modeling of steady flow of R-22 through capillary tubes
    • Kuehl S.J., Goldschmidt V.W. Modeling of steady flow of R-22 through capillary tubes. ASHRAE Trans. 97(1):1991;139-148.
    • (1991) ASHRAE Trans. , vol.97 , Issue.1 , pp. 139-148
    • Kuehl, S.J.1    Goldschmidt, V.W.2
  • 8
    • 0002743448 scopus 로고
    • Numerical and experimental studies on adiabatic and non-adiabatic capillary tubes with HFC-134a
    • West Lafayette, IN, USA
    • E. Dirik, C. Inan, M.Y. Tanes, Numerical and experimental studies on adiabatic and non-adiabatic capillary tubes with HFC-134a, in: Proceedings of the International Refrigeration Conference at Purdue, West Lafayette, IN, USA, 1994, pp. 365-370.
    • (1994) Proceedings of the International Refrigeration Conference at Purdue , pp. 365-370
    • Dirik, E.1    Inan, C.2    Tanes, M.Y.3
  • 10
    • 0031699375 scopus 로고    scopus 로고
    • A generalized performance prediction method for adiabatic capillary tubes
    • Bittle R.R., Wolf D.A., Pate M.B. A generalized performance prediction method for adiabatic capillary tubes. HVAC&R Res. 4(1):1998;27-43.
    • (1998) HVAC&R Res. , vol.4 , Issue.1 , pp. 27-43
    • Bittle, R.R.1    Wolf, D.A.2    Pate, M.B.3
  • 12
    • 0005748676 scopus 로고    scopus 로고
    • Experimentation and modeling on the flow of R407C and R290 through capillary tubes
    • Kim Y.C., Cho I.Y., Choi J.M. Experimentation and modeling on the flow of R407C and R290 through capillary tubes. Kor. J. Air-Condition. Refrig. Eng. 11(4):1999;492-498.
    • (1999) Kor. J. Air-Condition. Refrig. Eng. , vol.11 , Issue.4 , pp. 492-498
    • Kim, Y.C.1    Cho, I.Y.2    Choi, J.M.3
  • 13
    • 0033334642 scopus 로고    scopus 로고
    • Capillary tube selection for HCFC22 alternatives
    • Jung D., Park C., Park B. Capillary tube selection for HCFC22 alternatives. Int. J. Refrig. 22:1999;604-614.
    • (1999) Int. J. Refrig. , vol.22 , pp. 604-614
    • Jung, D.1    Park, C.2    Park, B.3
  • 15
    • 0035372236 scopus 로고    scopus 로고
    • Flow characteristics of pure refrigerants and refrigerant mixtures in adiabatic capillary tubes
    • Wongwises S., Pirompak W. Flow characteristics of pure refrigerants and refrigerant mixtures in adiabatic capillary tubes. Appl. Therm. Eng. 21:2001;845-861.
    • (2001) Appl. Therm. Eng. , vol.21 , pp. 845-861
    • Wongwises, S.1    Pirompak, W.2
  • 16
    • 0036679905 scopus 로고    scopus 로고
    • Experimental investigation of the performance of R22, R407C, and R410A in several capillary tubes for air-conditioner
    • Kim S.G., Kim M.S., Ro S.T. Experimental investigation of the performance of R22, R407C, and R410A in several capillary tubes for air-conditioner. Int. J. Refrig. 25:2002;521-531.
    • (2002) Int. J. Refrig. , vol.25 , pp. 521-531
    • Kim, S.G.1    Kim, M.S.2    Ro, S.T.3
  • 17
    • 0036650931 scopus 로고    scopus 로고
    • Experimental analysis of refrigerant mixtures flow through adiabatic capillary tubes
    • Fiorelli F., Huerta A., Silvares O. Experimental analysis of refrigerant mixtures flow through adiabatic capillary tubes. Exper. Therm. Fluid Sci. 26:2002;499-512.
    • (2002) Exper. Therm. Fluid Sci. , vol.26 , pp. 499-512
    • Fiorelli, F.1    Huerta, A.2    Silvares, O.3
  • 18
    • 36149025564 scopus 로고
    • On physically similar systems: Illustrations of the use of dimensional equations
    • Buckingham E. On physically similar systems: illustrations of the use of dimensional equations. Phys. Rev. 4(4):1914;345-376.
    • (1914) Phys. Rev. , vol.4 , Issue.4 , pp. 345-376
    • Buckingham, E.1
  • 20
    • 0000192077 scopus 로고
    • A correlation for metastable flow of refrigerant 12 through capillary tubes
    • Chen Z.H., Li R.Y., Lin S., Chen Z.Y. A correlation for metastable flow of refrigerant 12 through capillary tubes. ASHRAE Trans. 96(1):1990;550-554.
    • (1990) ASHRAE Trans. , vol.96 , Issue.1 , pp. 550-554
    • Chen, Z.H.1    Li, R.Y.2    Lin, S.3    Chen, Z.Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.