메뉴 건너뛰기




Volumn 59, Issue 1, 2003, Pages 79-85

Study of induced thermoluminescence in CVD diamond film by low-energy X-rays

Author keywords

CVD diamond; Low energy X ray; Thermoluminescence

Indexed keywords

CHEMICAL VAPOR DEPOSITION; DOSIMETRY; ENERGY TRANSFER; IRRADIATION; MONTE CARLO METHODS; THERMOLUMINESCENCE; X RAYS;

EID: 0142090456     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(03)00147-7     Document Type: Article
Times cited : (4)

References (17)
  • 4
    • 0033924708 scopus 로고    scopus 로고
    • Kinetics parameters of CVD diamond by computerized glow-curve deconvolution (CGCD)
    • Furetta C., Kitis G., Kuo C.-H. Kinetics parameters of CVD diamond by computerized glow-curve deconvolution (CGCD). Nucl. Instrum. Methods B. 160:2000;65-72.
    • (2000) Nucl. Instrum. Methods B , vol.160 , pp. 65-72
    • Furetta, C.1    Kitis, G.2    Kuo, C.-H.3
  • 7
    • 0035444384 scopus 로고    scopus 로고
    • Theory of heavy charge particle response (efficiency and superlinearity) in TL materials
    • Horowitz Y.S., Avila O., Rodriguez-Villafuerte M. Theory of heavy charge particle response (efficiency and superlinearity) in TL materials. Nucl. Instrum. Methods B. 184:2001;85-112.
    • (2001) Nucl. Instrum. Methods B , vol.184 , pp. 85-112
    • Horowitz, Y.S.1    Avila, O.2    Rodriguez-Villafuerte, M.3
  • 9
    • 0037213333 scopus 로고    scopus 로고
    • Indoor light on thermoluminescence of CVD diamond film used as a high energy photon dosimeter
    • Liu C.C., Chu T.C., Lin S.Y., Lin J P. Indoor light on thermoluminescence of CVD diamond film used as a high energy photon dosimeter. Appl. Radiat. Isot. 58:2003;89-94.
    • (2003) Appl. Radiat. Isot. , vol.58 , pp. 89-94
    • Liu, C.C.1    Chu, T.C.2    Lin, S.Y.3    Lin J, P.4
  • 12
    • 0030848615 scopus 로고    scopus 로고
    • A Monte Carlo study of the quality dependence of diamond thermoluminescence dosimeters in radiotherapy beams
    • Mobit P.N., Nahum A.E., Mayles P. A Monte Carlo study of the quality dependence of diamond thermoluminescence dosimeters in radiotherapy beams. Phys. Med. Biol. 42:1997;1913-1927.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1913-1927
    • Mobit, P.N.1    Nahum, A.E.2    Mayles, P.3
  • 13
    • 0032083688 scopus 로고    scopus 로고
    • 2:Tm (TLD-300) as a thermoluminescence one hit detector
    • 2:Tm (TLD-300) as a thermoluminescence one hit detector. Radiat. Meas. 29(3-4):1998;383-389.
    • (1998) Radiat. Meas. , vol.29 , Issue.3-4 , pp. 383-389
    • Olko, P.1
  • 14
    • 0036012707 scopus 로고    scopus 로고
    • The microdosimetric one-hit detector model for calculating the response of solid state detectors
    • Olko P. The microdosimetric one-hit detector model for calculating the response of solid state detectors. Radiat. Meas. 35:2002;255-267.
    • (2002) Radiat. Meas. , vol.35 , pp. 255-267
    • Olko, P.1
  • 15
    • 0027257649 scopus 로고
    • Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosimeters
    • Olko P., Bilski P., Ryba E., Niewiadomski T. Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosimeters. Radiat. Protect. Dosim. 47(1-4):1993;31-35.
    • (1993) Radiat. Protect. Dosim. , vol.47 , Issue.1-4 , pp. 31-35
    • Olko, P.1    Bilski, P.2    Ryba, E.3    Niewiadomski, T.4
  • 16
    • 0035184539 scopus 로고    scopus 로고
    • Fit of first order thermoluminescence glow peaks using the Weibull distribution function
    • Pagonis V., Mian S., Kitis G. Fit of first order thermoluminescence glow peaks using the Weibull distribution function. Radiat. Prot. Dosim. 93(1):2001;11-17.
    • (2001) Radiat. Prot. Dosim. , vol.93 , Issue.1 , pp. 11-17
    • Pagonis, V.1    Mian, S.2    Kitis, G.3