메뉴 건너뛰기




Volumn 48, Issue 10, 2003, Pages 287-290

Simulation of Bone Strain by Orthodontic Implants Using the Finite Element Method;Simulation der Knochenbelastung durch orthodontische Implantate mit Hilfe der Finite-Elemente-Methode

Author keywords

Bone deformation; Finite element method; Orthodontic implants

Indexed keywords

BIOMECHANICS; BONE; FINITE ELEMENT METHOD; IMPLANTS (SURGICAL);

EID: 0142086777     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/bmte.2003.48.10.287     Document Type: Article
Times cited : (6)

References (19)
  • 1
    • 0020711801 scopus 로고
    • Three-dimensional stress distribution around a dental implant at different stages of interface development
    • Borchers, L., Reichart, P.: Three-dimensional stress distribution around a dental implant at different stages of interface development. J. Dent. Res. 62 (1983), 155.
    • (1983) J. Dent. Res. , vol.62 , pp. 155
    • Borchers, L.1    Reichart, P.2
  • 2
    • 0026856162 scopus 로고
    • Pathogenesis of bony pocket formation around dental implants
    • Donath, K.: Pathogenesis of bony pocket formation around dental implants. J. Dent. Assoc. S. Afr. 47 (1992), 204.
    • (1992) J. Dent. Assoc. S. Afr. , vol.47 , pp. 204
    • Donath, K.1
  • 3
    • 0027031544 scopus 로고
    • Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis
    • Holmes, D. C., Grigsby, W. R., Goel, V. K., Keller, J. C.: Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis. Int. J. Oral Maxillofac. Implants 7 (1992), 450.
    • (1992) Int. J. Oral Maxillofac. Implants , vol.7 , pp. 450
    • Holmes, D.C.1    Grigsby, W.R.2    Goel, V.K.3    Keller, J.C.4
  • 4
    • 0034184752 scopus 로고    scopus 로고
    • Einfluß der Implantatgeometrie auf die Strain-Verteilung im periimplantären Knochen
    • Joos, U., Vollmer, D., Kleinheinz, J.: Einfluß der Implantatgeometrie auf die Strain-Verteilung im periimplantären Knochen. Mund Kiefer Gesichtschir. 4 (2000), 143.
    • (2000) Mund Kiefer Gesichtschir. , vol.4 , pp. 143
    • Joos, U.1    Vollmer, D.2    Kleinheinz, J.3
  • 8
    • 0027580884 scopus 로고
    • A comparison of methods to assess marginal bone height around endosseous implants
    • Meijer, H. J., Stehen, W. H., Bosman, F.: A comparison of methods to assess marginal bone height around endosseous implants. J. Clin. Periodontol. 20 (1993), 250.
    • (1993) J. Clin. Periodontol. , vol.20 , pp. 250
    • Meijer, H.J.1    Stehen, W.H.2    Bosman, F.3
  • 9
    • 0035011470 scopus 로고    scopus 로고
    • Bone loading pattern around implants in average and atrophic edentulous maxillae: A finite-element analysis
    • Meyer, U., Vollmer, D., Runte, C., Bourauel, C., Joos, U.: Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. J. Craniomaxillofac. Surg. 29 (2001), 100.
    • (2001) J. Craniomaxillofac. Surg. , vol.29 , pp. 100
    • Meyer, U.1    Vollmer, D.2    Runte, C.3    Bourauel, C.4    Joos, U.5
  • 10
    • 0028829288 scopus 로고
    • Detection of alkaline and acid phosphatases around titanium implants: A light microscopical and histochemical study in rabbits
    • Piattelli, A., Scarano, A., Piattelli, M.: Detection of alkaline and acid phosphatases around titanium implants: a light microscopical and histochemical study in rabbits. Biomaterials 16 (1995), 1333.
    • (1995) Biomaterials , vol.16 , pp. 1333
    • Piattelli, A.1    Scarano, A.2    Piattelli, M.3
  • 12
    • 0025441725 scopus 로고
    • Finite element analysis of six endosseous implants
    • Rieger, M. R., Mayberry, M., Brose, M. O.: Finite element analysis of six endosseous implants. J. Prosthet. Dent. 63 (1990), 671.
    • (1990) J. Prosthet. Dent. , vol.63 , pp. 671
    • Rieger, M.R.1    Mayberry, M.2    Brose, M.O.3
  • 14
    • 0024782190 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • Siegele, D., Soltesz, U.: Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int. J. Oral Maxillofac. Implants 4 (1989), 333.
    • (1989) Int. J. Oral Maxillofac. Implants , vol.4 , pp. 333
    • Siegele, D.1    Soltesz, U.2
  • 15
    • 0017999984 scopus 로고
    • Analysis of stress on a fixed partial denture with a blade-vent implant abutment
    • Takahashi, N., Kitagami, T., Komori, T.: Analysis of stress on a fixed partial denture with a blade-vent implant abutment. J. Prosthet. Dent. 40 (1978), 186.
    • (1978) J. Prosthet. Dent. , vol.40 , pp. 186
    • Takahashi, N.1    Kitagami, T.2    Komori, T.3
  • 17
    • 0033249983 scopus 로고    scopus 로고
    • Osteodynamics aro- und orthodontically loaded short maxillary implants. An experimental pilot study
    • Wehrbein, H., Yildirim, M., Diedrich, P.: Osteodynamics aro- und orthodontically loaded short maxillary implants. An experimental pilot study. J. Orofac. Orthop. 60 (1999), 409.
    • (1999) J. Orofac. Orthop. , vol.60 , pp. 409
    • Wehrbein, H.1    Yildirim, M.2    Diedrich, P.3
  • 18
    • 0028528407 scopus 로고
    • Enossale Titanimplantate als orthodontische Verankerungselemente
    • Wehrbein, H.: Enossale Titanimplantate als orthodontische Verankerungselemente. Fortschr. Kieferorthop. 55 (1994), 236.
    • (1994) Fortschr. Kieferorthop. , vol.55 , pp. 236
    • Wehrbein, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.