메뉴 건너뛰기




Volumn 30, Issue 10, 2003, Pages 2650-2662

Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system

Author keywords

Cardiac CT; ECG gated multislice CT; ECG gated spiral reconstruction; Multislice CT

Indexed keywords

AIR CUSHION VEHICLES; BIOMINERALIZATION; ELECTROCARDIOGRAPHY; FUNCTION EVALUATION; HEART; IMAGE RECONSTRUCTION; SCANNING; STENTS; VISUALIZATION;

EID: 0142070759     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1593637     Document Type: Article
Times cited : (62)

References (25)
  • 1
    • 0032414773 scopus 로고    scopus 로고
    • Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • M. Kachelriess and W. Kalender, "Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart," Med. Phys. 25, 2417-2431 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2417-2431
    • Kachelriess, M.1    Kalender, W.2
  • 2
    • 0000479811 scopus 로고    scopus 로고
    • Retrospectively ECG-gated spiral CT of the heart and lung
    • M. Bahner et al., "Retrospectively ECG-gated spiral CT of the heart and lung," Eur. Radiol. 9, 106-109 (1999).
    • (1999) Eur. Radiol. , vol.9 , pp. 106-109
    • Bahner, M.1
  • 3
    • 0033753104 scopus 로고    scopus 로고
    • Cardiac imaging by means of electrocardiographically gated multisection spiral CT-Initial experience
    • B. Ohnesorge et al., "Cardiac imaging by means of electrocardiographically gated multisection spiral CT-Initial experience," Radiology 217, 564-571 (2000).
    • (2000) Radiology , vol.217 , pp. 564-571
    • Ohnesorge, B.1
  • 4
    • 0034610434 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by retrospectively ECG-gated multi-slice Spiral CT
    • S. Achenbach et al., "Noninvasive coronary angiography by retrospectively ECG-gated multi-slice Spiral CT," Circulation 102, 2823-2828 (2000).
    • (2000) Circulation , vol.102 , pp. 2823-2828
    • Achenbach, S.1
  • 5
    • 0033853931 scopus 로고    scopus 로고
    • Imaging of non calcified coronary plaques using helical CT with retrospective EKG gating
    • C. Becker, A. Knez, B. Ohnesorge, U. Schöpf, and M. Reiser, "Imaging of non calcified coronary plaques using helical CT with retrospective EKG gating," Am. J. Roentgenol. 175, 423-424 (2000).
    • (2000) Am. J. Roentgenol. , vol.175 , pp. 423-424
    • Becker, C.1    Knez, A.2    Ohnesorge, B.3    Schöpf, U.4    Reiser, M.5
  • 6
    • 19244374259 scopus 로고    scopus 로고
    • Non-invasive assessment of coronary artery stenoses with multidetector helical computed tomography
    • A. Knez, C. Becker, A. Leber, B. Ohnesorge, M. Reiser, and R. Haberl, "Non-invasive assessment of coronary artery stenoses with multidetector helical computed tomography," Circulation 101, e221-e222 (2000).
    • (2000) Circulation , vol.101
    • Knez, A.1    Becker, C.2    Leber, A.3    Ohnesorge, B.4    Reiser, M.5    Haberl, R.6
  • 8
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    • M. Kachelriess, S. Ulzheimer, and W. Kalender, "ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart," Med. Phys. 27, 1881-1902 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1881-1902
    • Kachelriess, M.1    Ulzheimer, S.2    Kalender, W.3
  • 9
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multi-slice helical computed tomography
    • K. Taguchi and H. Anno, "High temporal resolution for multi-slice helical computed tomography," Med. Phys. 27, 861-872 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 10
    • 0035176903 scopus 로고    scopus 로고
    • Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart
    • T. Flohr and B. Ohnesorge, "Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart," JCAT 25, 907-923 (2001).
    • (2001) JCAT , vol.25 , pp. 907-923
    • Flohr, T.1    Ohnesorge, B.2
  • 11
    • 0035312512 scopus 로고    scopus 로고
    • Noninvasive detection and evaluation of atherosclerotic coronary plaques with multi-slice computed tomography
    • S. Schroeder et al., "Noninvasive detection and evaluation of atherosclerotic coronary plaques with multi-slice computed tomography," JACC 37, 1430-1435 (2001).
    • (2001) JACC , vol.37 , pp. 1430-1435
    • Schroeder, S.1
  • 12
    • 0034867726 scopus 로고    scopus 로고
    • ECG-gated reconstructed multi-detector row CT coronary angiography: Effect of varying trigger delay on image quality
    • C. Hong, C. Becker, A. Huber, U. Schoepf, B. Ohnesorge, A. Knez, R. Brüning, and M. Reiser, "ECG-gated reconstructed multi-detector row CT coronary angiography: Effect of varying trigger delay on image quality, " Radiology 220, 712-717 (2001).
    • (2001) Radiology , vol.220 , pp. 712-717
    • Hong, C.1    Becker, C.2    Huber, A.3    Schoepf, U.4    Ohnesorge, B.5    Knez, A.6    Brüning, R.7    Reiser, M.8
  • 13
    • 0035191747 scopus 로고    scopus 로고
    • Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    • A. Kopp, S. Schroeder, A. Kuettner, M. Heuschmid, C. Georg, B. Ohnesorge, R. Kuzo, and C. Claussen, "Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window," Radiology 221, 683-688 (2001).
    • (2001) Radiology , vol.221 , pp. 683-688
    • Kopp, A.1    Schroeder, S.2    Kuettner, A.3    Heuschmid, M.4    Georg, C.5    Ohnesorge, B.6    Kuzo, R.7    Claussen, C.8
  • 14
    • 0019533519 scopus 로고
    • Some windows with very good sidelobe behavior
    • A. Nuttal, "Some windows with very good sidelobe behavior," IEEE Trans. Acoust., Speech, Signal Process. ASSP-29(1), 84-91 (1981).
    • (1981) IEEE Trans. Acoust., Speech, Signal Process. , vol.ASSP-29 1 , pp. 84-91
    • Nuttal, A.1
  • 15
    • 0037573220 scopus 로고    scopus 로고
    • Image reconstruction and image quality evaluation for a 16-slice CT scanner
    • T. Flohr, K. Stierstorfer, H. Bruder, J. Simon, A. Polacin, and S. Schaller, "Image reconstruction and image quality evaluation for a 16-slice CT scanner," Med. Phys. 30, 832-845 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 832-845
    • Flohr, T.1    Stierstorfer, K.2    Bruder, H.3    Simon, J.4    Polacin, A.5    Schaller, S.6
  • 18
    • 0036325261 scopus 로고    scopus 로고
    • New technical developments in multislice CT, Part 1: Approaching isotropic resolution with sub-mm 16-slice scanning
    • T. Flohr, K. Stierstorfer, H. Bruder, J. Simon, and S. Schaller, "New technical developments in multislice CT, Part 1: Approaching isotropic resolution with sub-mm 16-slice scanning," Fortschr Röntgenstr. 174, 839-845 (2002).
    • (2002) Fortschr Röntgenstr. , vol.174 , pp. 839-845
    • Flohr, T.1    Stierstorfer, K.2    Bruder, H.3    Simon, J.4    Schaller, S.5
  • 22
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • H. Hu, "Multi-slice helical CT: Scan and reconstruction," Med. Phys. 26, 5-18 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 5-18
    • Hu, H.1
  • 23
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • K. Taguchi and H. Aradate, "Algorithm for image reconstruction in multi-slice helical CT," Med. Phys. 25, 550-561 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 550-561
    • Taguchi, K.1    Aradate, H.2
  • 24
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    • K. Nieman, F. Cademartiri, P. A. Lemos, R. Raaijmakers, P. M. T. Pattynama, and P. J. de Feyter, "Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography," Circulation 106, 2051-2054 (2002).
    • (2002) Circulation , vol.106 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3    Raaijmakers, R.4    Pattynama, P.M.T.5    De Feyter, P.J.6
  • 25
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenosis with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • D. Ropers et al., "Detection of coronary artery stenosis with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction," Circulation 107, 664-666 (2003).
    • (2003) Circulation , vol.107 , pp. 664-666
    • Ropers, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.