메뉴 건너뛰기




Volumn 36, Issue 13, 2003, Pages 2783-2792

Chemiluminescence Flow-Through Sensor for the Determination of Ascorbic Acid with an Immobilized Reagent

Author keywords

Ascorbic acid; Chemiluminescence; Flow through sensor; Immobilized reagent

Indexed keywords

ASCORBIC ACID; MANGANESE DERIVATIVE; PERMANGANATE; REAGENT; UNCLASSIFIED DRUG;

EID: 0142063482     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-120025255     Document Type: Article
Times cited : (4)

References (17)
  • 1
    • 34250088839 scopus 로고
    • Immobilized and solid-state reagent systems for luminol chemiluminescence in flow systems
    • Nieman, T.A. Immobilized and solid-state reagent systems for luminol chemiluminescence in flow systems. Microchim. Acta [Wien], III (1-6) 1988, 239.
    • (1988) Microchim. Acta [Wien] , vol.3 , Issue.1-6 , pp. 239
    • Nieman, T.A.1
  • 2
    • 0024012119 scopus 로고
    • Immobilized luminol chemiluminescence reagent system for hydrogen peroxide determinations in flowing streams
    • Hool, K.; Nieman, T.A. Immobilized luminol chemiluminescence reagent system for hydrogen peroxide determinations in flowing streams. Anal. Chem. 1988, 60, 834.
    • (1988) Anal. Chem. , vol.60 , pp. 834
    • Hool, K.1    Nieman, T.A.2
  • 3
    • 0023310650 scopus 로고
    • Chemiluminescence analysis in flowing streams with luminol immobilized on silica and controlled-pore glass
    • Hool, K.; Nieman, T.A. Chemiluminescence analysis in flowing streams with luminol immobilized on silica and controlled-pore glass. Anal. Chem. 1987, 59, 869.
    • (1987) Anal. Chem. , vol.59 , pp. 869
    • Hool, K.1    Nieman, T.A.2
  • 4
    • 0022117518 scopus 로고
    • Immobilized fluorophores in dynamic chemiluminescence detection of hydrogen peroxide
    • Gubitz, G.; van Zoonen, P.; Gooijer, C.; Velthorst, N.H.; Frei, R.W. Immobilized fluorophores in dynamic chemiluminescence detection of hydrogen peroxide. Anal. Chem. 1985, 57, 2071.
    • (1985) Anal. Chem. , vol.57 , pp. 2071
    • Gubitz, G.1    Van Zoonen, P.2    Gooijer, C.3    Velthorst, N.H.4    Frei, R.W.5
  • 5
    • 0000835014 scopus 로고
    • Solid-state chemiluminescence detector for hydrogen peroxide based on an immobilized luminophore. Application to rain-water
    • van Zoonen, P.; Kamminga, D.A.; Gooijer, C.; Velthorst, N.H.; Frei, R.W. ; Gubitz, G. Solid-state chemiluminescence detector for hydrogen peroxide based on an immobilized luminophore. Application to rain-water. Anal. Chim. Acta 1985, 174, 151.
    • (1985) Anal. Chim. Acta , vol.174 , pp. 151
    • Van Zoonen, P.1    Kamminga, D.A.2    Gooijer, C.3    Velthorst, N.H.4    Frei, R.W.5    Gubitz, G.6
  • 6
    • 0026811278 scopus 로고
    • Chemiluminescence detection using regenerable tris-(2,2′ -bipyridyl)ruthenium(II) immobilized in Nafion
    • Downey, T.M.; Nieman, T.A. Chemiluminescence detection using regenerable tris-(2,2′-bipyridyl)ruthenium(II) immobilized in Nafion. Anal. Chem. 1992, 64, 261.
    • (1992) Anal. Chem. , vol.64 , pp. 261
    • Downey, T.M.1    Nieman, T.A.2
  • 7
    • 24244470115 scopus 로고
    • Immobilized 1-bromonaphthalene for quenched phosphorescence detection in high performance liquid chromatography
    • Baumann, R.A.; Gooijer, C.; Velthorst, N.H.; Frei, R.W.; Aichinger, I.; Gubitz, G. Immobilized 1-bromonaphthalene for quenched phosphorescence detection in high performance liquid chromatography. Anal. Chem. 1988, 60, 1237.
    • (1988) Anal. Chem. , vol.60 , pp. 1237
    • Baumann, R.A.1    Gooijer, C.2    Velthorst, N.H.3    Frei, R.W.4    Aichinger, I.5    Gubitz, G.6
  • 8
    • 0034938933 scopus 로고    scopus 로고
    • Chemiluminescence flow sensor for berberine with immobilized reagents
    • Song, Z.; Zhao, T.; Wang, L.; Xiao, Z. Chemiluminescence flow sensor for berberine with immobilized reagents. Bioorg. Med. Chem. 2001, 9 (7), 1701-1705.
    • (2001) Bioorg. Med. Chem. , vol.9 , Issue.7 , pp. 1701-1705
    • Song, Z.1    Zhao, T.2    Wang, L.3    Xiao, Z.4
  • 9
    • 0035057730 scopus 로고    scopus 로고
    • Hydrogen peroxide chemiluminescent flow-through sensor based on the oxidation with periodate immobilized on ion-exchange resin
    • Lin, J.M.; Sato, K.; Yamada, M. Hydrogen peroxide chemiluminescent flow-through sensor based on the oxidation with periodate immobilized on ion-exchange resin. Microchem. J. 2001, 69 (1), 73-80.
    • (2001) Microchem. J. , vol.69 , Issue.1 , pp. 73-80
    • Lin, J.M.1    Sato, K.2    Yamada, M.3
  • 10
    • 0032540516 scopus 로고    scopus 로고
    • Reagentless chemiluminescence flow sensor for sulfite
    • Qin, W.; Zhang, Z.J.; Zhang, C.J. Reagentless chemiluminescence flow sensor for sulfite. Anal. Chim. Acta 1998, 361, 201.
    • (1998) Anal. Chim. Acta , vol.361 , pp. 201
    • Qin, W.1    Zhang, Z.J.2    Zhang, C.J.3
  • 11
    • 0035909446 scopus 로고    scopus 로고
    • Flow-injection chemiluminescence sensor for the determination of isoniazid
    • Zhang, S.; Li, H. Flow-injection chemiluminescence sensor for the determination of isoniazid. Anal. Chim. Acta 2001, 444 (2), 287-294.
    • (2001) Anal. Chim. Acta , vol.444 , Issue.2 , pp. 287-294
    • Zhang, S.1    Li, H.2
  • 12
    • 0037158255 scopus 로고    scopus 로고
    • Development of integrated chemiluminescence flow sensor for the determination of adrenaline and isoprenaline
    • Zhou, G.J.; Zhang, G.F.; Chen, H.Y. Development of integrated chemiluminescence flow sensor for the determination of adrenaline and isoprenaline. Anal. Chim. Acta 2002, 463 (2), 257-263.
    • (2002) Anal. Chim. Acta , vol.463 , Issue.2 , pp. 257-263
    • Zhou, G.J.1    Zhang, G.F.2    Chen, H.Y.3
  • 13
    • 0025217202 scopus 로고
    • Chemiluminescence sensor with uranine immobilized on an anion-exchange resin for monitoring free chlorine in tap-water
    • Nakagama, T.; Yamada, M.; Hobo, T. Chemiluminescence sensor with uranine immobilized on an anion-exchange resin for monitoring free chlorine in tap-water. Anal. Chim. Acta 1990, 231, 7.
    • (1990) Anal. Chim. Acta , vol.231 , pp. 7
    • Nakagama, T.1    Yamada, M.2    Hobo, T.3
  • 14
    • 0028940516 scopus 로고
    • A flow-injection type chemiluminescence-based sensor for cyanide
    • Lu, J.Z.; Qin, W.; Zhang, Z.J.; Feng, M.L.; Wang, Y.J. A flow-injection type chemiluminescence-based sensor for cyanide. Anal. Chim. Acta 1995, 304, 369.
    • (1995) Anal. Chim. Acta , vol.304 , pp. 369
    • Lu, J.Z.1    Qin, W.2    Zhang, Z.J.3    Feng, M.L.4    Wang, Y.J.5
  • 15
    • 0029613882 scopus 로고
    • Chemiluminescence flow system for the monitoring of chromium (VI) in water
    • Zhang, Z.J.; Qin, W.; Liu, S.N. Chemiluminescence flow system for the monitoring of chromium (VI) in water. Anal. Chim. Acta 1995, 318, 71.
    • (1995) Anal. Chim. Acta , vol.318 , pp. 71
    • Zhang, Z.J.1    Qin, W.2    Liu, S.N.3
  • 16
    • 0031578743 scopus 로고    scopus 로고
    • Direct chemiluminescence determination of ascorbic acid using flow-injection analysis
    • Agater, I.B.; Jewsbury, R.A. Direct chemiluminescence determination of ascorbic acid using flow-injection analysis. Anal. Chim. Acta 1997, 356, 289.
    • (1997) Anal. Chim. Acta , vol.356 , pp. 289
    • Agater, I.B.1    Jewsbury, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.