메뉴 건너뛰기




Volumn 18, Issue 5, 2003, Pages 712-718

Robot-assisted placement of craniofacial implants

Author keywords

Auricular prosthesis; Craniofacial implant; Rapid prototyping; Robotics

Indexed keywords

ACCURACY; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CRANIOFACIAL SURGERY; EAR SURGERY; ESTHETIC SURGERY; HEARING AID; HUMAN; IMPLANT; MATERIALS TESTING; MEASUREMENT; MICROTIA; PEROPERATIVE CARE; PREOPERATIVE CARE; PROSTHESIS; REHABILITATION; ROBOTICS;

EID: 0142056935     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (24)

References (25)
  • 1
    • 0024216504 scopus 로고
    • Classification of congenital deformities of the auricle
    • Weerda H. Classification of congenital deformities of the auricle. Facial Plast Surg 1988;5:385-388.
    • (1988) Facial Plast Surg , vol.5 , pp. 385-388
    • Weerda, H.1
  • 3
    • 1842326223 scopus 로고    scopus 로고
    • Combined aesthetic and functional treatment of microtia
    • Meyer R, de Goumoens R, Derder S. Combined aesthetic and functional treatment of microtia. Aesthet Plast Surg 1997;21:159-167.
    • (1997) Aesthet Plast Surg , vol.21 , pp. 159-167
    • Meyer, R.1    De Goumoens, R.2    Derder, S.3
  • 4
    • 0026799504 scopus 로고
    • Auricular repair with autogenous rib cartilage grafts: Two decades of experience with 600 cases
    • Brent B. Auricular repair with autogenous rib cartilage grafts: Two decades of experience with 600 cases. Plast Reconstr Surg 1992;90:355-374.
    • (1992) Plast Reconstr Surg , vol.90 , pp. 355-374
    • Brent, B.1
  • 5
    • 0028354781 scopus 로고
    • Osseointegrated and alloplastic versus autogenous ear reconstruction: Criteria for treatment selection
    • Wilkes GH, Wolfaardt JF. Osseointegrated and alloplastic versus autogenous ear reconstruction: Criteria for treatment selection. Plast Reconstr Surg 1994;93:967-979.
    • (1994) Plast Reconstr Surg , vol.93 , pp. 967-979
    • Wilkes, G.H.1    Wolfaardt, J.F.2
  • 6
    • 0024991830 scopus 로고
    • Osseointegrated implants for replacement of absent or defective ears
    • Tjellstrom A. Osseointegrated implants for replacement of absent or defective ears. Clin Plast Surg 1990;17:355-366.
    • (1990) Clin Plast Surg , vol.17 , pp. 355-366
    • Tjellstrom, A.1
  • 7
    • 0029067763 scopus 로고
    • One-stage procedure to establish osseointegration: A zero to five years follow-up report
    • Tjellstrom A, Granstrom G. One-stage procedure to establish osseointegration: A zero to five years follow-up report. J Laryngol Otol 1995;109:593-598.
    • (1995) J Laryngol Otol , vol.109 , pp. 593-598
    • Tjellstrom, A.1    Granstrom, G.2
  • 8
    • 0031201526 scopus 로고    scopus 로고
    • Computed tomographic study of bone availability for facial prosthesis-bearing endosteal implants
    • Klein M, Menneking H, Neumann K, Hell B, Bier J. Computed tomographic study of bone availability for facial prosthesis-bearing endosteal implants. Int J Oral Maxillofac Surg 1997;26:268-271.
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 268-271
    • Klein, M.1    Menneking, H.2    Neumann, K.3    Hell, B.4    Bier, J.5
  • 10
    • 0035221148 scopus 로고    scopus 로고
    • CT-Computer-schablonen-gestützte Planung der Implantat- und Magnetposition bei der epithetischen Versorgung von Gesichtsdefekten
    • Schlieper J, Brinkmann B, Metz HJ. CT-Computer-schablonen-gestützte Planung der Implantat- und Magnetposition bei der epithetischen Versorgung von Gesichtsdefekten. Mund Kiefer Gesichtschir 2001;5:22-27.
    • (2001) Mund Kiefer Gesichtschir , vol.5 , pp. 22-27
    • Schlieper, J.1    Brinkmann, B.2    Metz, H.J.3
  • 11
    • 0028279101 scopus 로고
    • Steco-Titanmagnetics - Ein neues magnetattachement
    • Köhler S, Schmelzle R, Stemmann HJ. Steco-Titanmagnetics - Ein neues Magnetattachement. HNO 1994;42:173-176.
    • (1994) HNO , vol.42 , pp. 173-176
    • Köhler, S.1    Schmelzle, R.2    Stemmann, H.J.3
  • 12
    • 0003816485 scopus 로고    scopus 로고
    • Measurement of the slice distance accuracy of the mobile CT Tomoscan
    • Lemke HU (ed). Cars 2000: Computer Assisted Radiology and Surgery, San Francisco, 28 June-1 July 2000. Amsterdam: Elsevier
    • Albrecht J, Lueth T, Hein A, Bier J. Measurement of the slice distance accuracy of the mobile CT Tomoscan. In: Lemke HU (ed). Cars 2000: Computer Assisted Radiology and Surgery. Proceedings of the 14th International Congress and Exhibition, San Francisco, 28 June-1 July 2000. Amsterdam: Elsevier, 2000:651-655.
    • (2000) Proceedings of the 14th International Congress and Exhibition , pp. 651-655
    • Albrecht, J.1    Lueth, T.2    Hein, A.3    Bier, J.4
  • 14
  • 15
    • 0142047914 scopus 로고    scopus 로고
    • Evaluierung eines interaktiv bedienbaren Roboters zur Platzierung von Knochenankern
    • Hein A, Lüth T, Klein M, Bier J. Evaluierung eines interaktiv bedienbaren Roboters zur Platzierung von Knochenankern. Orthop Prax 2001;37(1):23-28.
    • (2001) Orthop Prax , vol.37 , Issue.1 , pp. 23-28
    • Hein, A.1    Lüth, T.2    Klein, M.3    Bier, J.4
  • 16
    • 0033109044 scopus 로고    scopus 로고
    • Presurgical confirmation of craniofacial implant localizations in children requiring implant-retained auricular prosthesis
    • Wang R. Presurgical confirmation of craniofacial implant localizations in children requiring implant-retained auricular prosthesis. J Prosthet Dent 1999;81(4):492-495.
    • (1999) J Prosthet Dent , vol.81 , Issue.4 , pp. 492-495
    • Wang, R.1
  • 17
    • 0027909259 scopus 로고
    • Robodoc: Study tests robot's use in hip surgery
    • Taylor KS. Robodoc: Study tests robot's use in hip surgery. Hospitals 1993;67(9):46.
    • (1993) Hospitals , vol.67 , Issue.9 , pp. 46
    • Taylor, K.S.1
  • 18
    • 0031719836 scopus 로고    scopus 로고
    • Primary and revision total hip replacement using the Robodoc system
    • Bargar WL, Bauer A, Borner M. Primary and revision total hip replacement using the Robodoc system. Clin Orthop 1998;354:82-91.
    • (1998) Clin Orthop , vol.354 , pp. 82-91
    • Bargar, W.L.1    Bauer, A.2    Borner, M.3
  • 19
    • 0034441845 scopus 로고    scopus 로고
    • Minimally invasive videoscopic mitral valve sugery: The current role of surgical robotics
    • Chitwood WR, Nifong LW. Minimally invasive videoscopic mitral valve sugery: The current role of surgical robotics. J Card Surg 2000;15(1):61-75.
    • (2000) J Card Surg , vol.15 , Issue.1 , pp. 61-75
    • Chitwood, W.R.1    Nifong, L.W.2
  • 20
    • 0035353719 scopus 로고    scopus 로고
    • Computer-enhanced "robotic" cardiac surgery: Experiences in 148 patients
    • Mohr FW, Falk V, Diegeler A, et al. Computer-enhanced "robotic" cardiac surgery: Experiences in 148 patients. J Thorac Cardiovasc Surg 2001;121(5):842-853.
    • (2001) J Thorac Cardiovasc Surg , vol.121 , Issue.5 , pp. 842-853
    • Mohr, F.W.1    Falk, V.2    Diegeler, A.3
  • 21
    • 0032993055 scopus 로고    scopus 로고
    • Use of the voice-controlled and computer-assisted surgical system ZEUS for endoscopic coronary artery bypass grafting
    • Reichenspurner H, Damiano RJ, Mack M, et al. Use of the voice-controlled and computer-assisted surgical system ZEUS for endoscopic coronary artery bypass grafting. J Thorac Cardiovasc Surg 1999;118(1):11-16.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , Issue.1 , pp. 11-16
    • Reichenspurner, H.1    Damiano, R.J.2    Mack, M.3
  • 22
    • 0033030669 scopus 로고    scopus 로고
    • Image-guided neurosurgery/neuronavigation/the SurgiScope - Reflections on a theme
    • Haase J. Image-guided neurosurgery/neuronavigation/the SurgiScope - Reflections on a theme. Minim Invasive Neurosurg 1999;42(2):53-59.
    • (1999) Minim Invasive Neurosurg , vol.42 , Issue.2 , pp. 53-59
    • Haase, J.1
  • 23
    • 0032993645 scopus 로고    scopus 로고
    • Technical considerations regarding accuracy of the MKM navigation system. An experimental study on impact factors
    • Kaminsky J, Brinker T, Samii A, Arango G, Vorkapic P, Samii M. Technical considerations regarding accuracy of the MKM navigation system. An experimental study on impact factors. Neurol Res 1999;21(4):420-424.
    • (1999) Neurol Res , vol.21 , Issue.4 , pp. 420-424
    • Kaminsky, J.1    Brinker, T.2    Samii, A.3    Arango, G.4    Vorkapic, P.5    Samii, M.6
  • 25
    • 0024863947 scopus 로고
    • A laser scanning system for the measurement of facial surface morphology
    • Moss JP, Linney AD, Grinderod SR, Mosse CA. A laser scanning system for the measurement of facial surface morphology. Opt Laser Eng 1989;10:179-190.
    • (1989) Opt Laser Eng , vol.10 , pp. 179-190
    • Moss, J.P.1    Linney, A.D.2    Grinderod, S.R.3    Mosse, C.A.4