메뉴 건너뛰기




Volumn 76, Issue 910, 2003, Pages 731-737

A model for calculating shielding requirements in diagnostic X-ray facilities

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BUILDING MATERIAL; CALCULATION; CONTROLLED STUDY; HEALTH CARE FACILITY; HUMAN; MATHEMATICAL MODEL; MEDICAL STAFF; RADIATION PROTECTION; RADIATION SHIELD; RADIODIAGNOSIS; X IRRADIATION;

EID: 0142028251     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/21741358     Document Type: Article
Times cited : (9)

References (16)
  • 2
    • 0023192855 scopus 로고
    • A general solution to the shielding of medical x and γ rays by the NCRP report no. 49 methods
    • Simpkin DJ. A general solution to the shielding of medical x and γ rays by the NCRP report no. 49 methods. Health Phys 1987;52:431-6.
    • (1987) Health Phys , vol.52 , pp. 431-436
    • Simpkin, D.J.1
  • 4
    • 0028127040 scopus 로고
    • On the primary barrier in diagnostic shielding
    • Dixon RL. On the primary barrier in diagnostic shielding. Med Phys 1994;21:1785-94.
    • (1994) Med Phys , vol.21 , pp. 1785-1794
    • Dixon, R.L.1
  • 5
    • 0031933709 scopus 로고    scopus 로고
    • Primary shielding barriers for diagnostic X-ray facilities: A new model
    • Dixon RL, Simpkin DJ. Primary shielding barriers for diagnostic X-ray facilities: A new model. Health Phys 1998;74:181-9.
    • (1998) Health Phys , vol.74 , pp. 181-189
    • Dixon, R.L.1    Simpkin, D.J.2
  • 6
    • 0017197401 scopus 로고
    • Leakage radiation from a diagnostic tube housing when operated at less than the maximum rated kilovoltage
    • Kelley JP, Trout ED, Larson VL. Leakage radiation from a diagnostic tube housing when operated at less than the maximum rated kilovoltage. Health Phys 1976;31:27-31.
    • (1976) Health Phys , vol.31 , pp. 27-31
    • Kelley, J.P.1    Trout, E.D.2    Larson, V.L.3
  • 7
    • 0031891513 scopus 로고    scopus 로고
    • Secondary shielding barriers for diagnostic X-ray facilities: Scatter and leakage revisited
    • Simpkin DJ, Dixon RL. Secondary shielding barriers for diagnostic X-ray facilities: Scatter and leakage revisited. Health Phys 1998;74:350-65.
    • (1998) Health Phys , vol.74 , pp. 350-365
    • Simpkin, D.J.1    Dixon, R.L.2
  • 8
    • 0007944358 scopus 로고    scopus 로고
    • Evaluation of NCRP report No. 49 assumptions on workloads and use factors in diagnostic radiology
    • Simpkin DJ. Evaluation of NCRP report No. 49 assumptions on workloads and use factors in diagnostic radiology. Med Phys 1996;23:577-84.
    • (1996) Med Phys , vol.23 , pp. 577-584
    • Simpkin, D.J.1
  • 10
    • 0028041154 scopus 로고
    • Attenuation properties of diagnostic X-ray shielding materials
    • Archer BR, Fewell TR, Conway BJ, Quinn PW. Attenuation properties of diagnostic X-ray shielding materials. Med Phys 1994;21:1499-507.
    • (1994) Med Phys , vol.21 , pp. 1499-1507
    • Archer, B.R.1    Fewell, T.R.2    Conway, B.J.3    Quinn, P.W.4
  • 11
    • 0020528004 scopus 로고
    • Diagnostic X-ray shielding design based on an empirical model of photon attenuation
    • Archer BR, Thornby JI, Bushong SC. Diagnostic X-ray shielding design based on an empirical model of photon attenuation. Health Phys 1983;44:507-17.
    • (1983) Health Phys , vol.44 , pp. 507-517
    • Archer, B.R.1    Thornby, J.I.2    Bushong, S.C.3
  • 12
    • 0025945052 scopus 로고
    • Broad beam transmission properties of some common shielding materials for use in diagnostic radiology
    • Rossi RP, Ritenour R, Christodoulou E. Broad beam transmission properties of some common shielding materials for use in diagnostic radiology. Health Phys 1991;61:601-8.
    • (1991) Health Phys , vol.61 , pp. 601-608
    • Rossi, R.P.1    Ritenour, R.2    Christodoulou, E.3
  • 15
    • 0028939930 scopus 로고
    • Transmission data for shielding diagnostic X-ray facilities
    • Simpkin DJ. Transmission data for shielding diagnostic X-ray facilities. Health Phys 1995;68:704-9.
    • (1995) Health Phys , vol.68 , pp. 704-709
    • Simpkin, D.J.1
  • 16
    • 0023407196 scopus 로고
    • Shielding requirements for mammography
    • Simpkin DJ. Shielding requirements for mammography. Health Phys 1987;53:267-79.
    • (1987) Health Phys , vol.53 , pp. 267-279
    • Simpkin, D.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.