Volumn 26, Issue 4, 2003, Pages 429-436

Mechanisms of rupture of knitted polyester vascular prostheses: An in vitro analysis of virgin prostheses

Author keywords

Blood vessel prosthesis; Degradation; Polyester; Rupture; Vascular grafts

Indexed keywords

POLYESTER;

EID: 0142028022     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1078-5884(03)00257-0     Document Type: Article
Times cited : (25)

References (18)
  • 1
    • 0039581488 scopus 로고
    • Aneurysmal deterioration of arterial substitutes
    • Ernst CB, Stanley JC, Decker BC, eds
    • Guidoin R, Chakfé N. Aneurysmal deterioration of arterial substitutes. In: Ernst CB, Stanley JC, Decker BC, eds. Current Therapy in Vascular Surgery. ; 1990: 324-328.
    • (1990) Current Therapy in Vascular Surgery , pp. 324-328
    • Guidoin, R.1    Chakfé, N.2
  • 2
    • 0019475829 scopus 로고
    • Late fiber deterioration in Dacron® arterial grafts
    • Berger K, Sauvage LR. Late fiber deterioration in Dacron® arterial grafts. Ann Surg 1981; 193: 477-491.
    • (1981) Ann. Surg. , vol.193 , pp. 477-491
    • Berger, K.1    Sauvage, L.R.2
  • 3
    • 0018772816 scopus 로고
    • Postoperative alterations in size of Dacron® aortic grafts. An ultrasonic evaluation
    • Nunn DB, Freeman MH, Hudgins PC. Postoperative alterations in size of Dacron® aortic grafts. An ultrasonic evaluation. Ann Surg 1979; 189: 741-745.
    • (1979) Ann. Surg. , vol.189 , pp. 741-745
    • Nunn, D.B.1    Freeman, M.H.2    Hudgins, P.C.3
  • 4
    • 0022691602 scopus 로고
    • On the correlation between the failure of vascular grafts and their structural and material properties: A critical analysis
    • Pourdeyhimi B, Wagner D. On the correlation between the failure of vascular grafts and their structural and material properties: a critical analysis. J Biomed Mater Res 1986; 20: 375-409.
    • (1986) J. Biomed. Mater. Res. , vol.20 , pp. 375-409
    • Pourdeyhimi, B.1    Wagner, D.2
  • 5
    • 0015423691 scopus 로고
    • An unusual complication of axillo-femoral bypass
    • Ottinger MB, Rutherford RB, Skinner DB. An unusual complication of axillo-femoral bypass. Surgery 1972; 72: 769-771.
    • (1972) Surgery , vol.72 , pp. 769-771
    • Ottinger, M.B.1    Rutherford, R.B.2    Skinner, D.B.3
  • 6
    • 0017056020 scopus 로고
    • Failure of ultralightweight knitted Dacron grafts in arterial reconstructions
    • Ottinger LW, Darling C, Wirthlin LS et al. Failure of ultralightweight knitted Dacron grafts in arterial reconstructions. Arch Surg 1976; 111: 146-149.
    • (1976) Arch. Surg. , vol.111 , pp. 146-149
    • Ottinger, L.W.1    Darling, C.2    Wirthlin, L.S.3
  • 7
    • 0017313766 scopus 로고
    • Arterial replacement: Failure of synthetic prostheses
    • Hussey HH. Arterial replacement: failure of synthetic prostheses. JAMA 1976; 235: 848.
    • (1976) JAMA , vol.235 , pp. 848
    • Hussey, H.H.1
  • 8
    • 0018571172 scopus 로고
    • Knitted Dacron ultralight weight grafts: A warning
    • Lynn RB. Knitted Dacron ultralight weight grafts: a warning. Can J Surg 1979; 22: 593.
    • (1979) Can. J. Surg. , vol.22 , pp. 593
    • Lynn, R.B.1
  • 9
    • 0017327555 scopus 로고
    • Failure of knitted Dacron as an arterial prosthesis
    • Blumenberg RM, Gelfand ML. Failure of knitted Dacron as an arterial prosthesis. Surgery 1977; 81: 493-496.
    • (1977) Surgery , vol.81 , pp. 493-496
    • Blumenberg, R.M.1    Gelfand, M.L.2
  • 10
    • 0021777169 scopus 로고
    • Late rupture of knitted Dacron double velour arterial prostheses
    • Trippestad A. Late rupture of knitted Dacron double velour arterial prostheses. Acta Chir Scand 1985; 151: 391-395.
    • (1985) Acta Chir. Scand. , vol.151 , pp. 391-395
    • Trippestad, A.1
  • 12
    • 0018128856 scopus 로고
    • Failure of Dacron prosthesis cause by structural defect
    • Yashar JJ, Richman MH, Dyckman J et al. Failure of Dacron prosthesis cause by structural defect. Surgery 1978; 84: 659-663.
    • (1978) Surgery , vol.84 , pp. 659-663
    • Yashar, J.J.1    Richman, M.H.2    Dyckman, J.3
  • 13
    • 0021130591 scopus 로고
    • Aneurysms of a double velours aortic graft
    • Nucho RC, Gryborski WA. Aneurysms of a double velours aortic graft. Arch Surg 1984; 119: 1182-1184.
    • (1984) Arch. Surg. , vol.119 , pp. 1182-1184
    • Nucho, R.C.1    Gryborski, W.A.2
  • 16
    • 18044401317 scopus 로고    scopus 로고
    • Longitudinal ruptures of polyester knitted vascular prostheses
    • Chakfé N, Riepe G, Diéval F et al. Longitudinal ruptures of polyester knitted vascular prostheses. J Vasc Surg 2001; 33: 1015-1021.
    • (2001) J. Vasc. Surg. , vol.33 , pp. 1015-1021
    • Chakfé, N.1    Riepe, G.2    Diéval, F.3
  • 18
    • 0035282584 scopus 로고    scopus 로고
    • Polyester fiber and microfiber structure by critical dissolution time
    • Diéval F, Mathieu D, Durand B. Polyester fiber and microfiber structure by critical dissolution time. Text Res J 2001; 71: 239-246.
    • (2001) Text Res. J. , vol.71 , pp. 239-246
    • Diéval, F.1    Mathieu, D.2    Durand, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.