메뉴 건너뛰기




Volumn 17, Issue 3, 2003, Pages 234-240

Low level leucocyte counting (LLLC) in blood products

Author keywords

[No Author keywords available]

Indexed keywords

REAGENT;

EID: 0141996316     PISSN: 0393974X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 0033845096 scopus 로고    scopus 로고
    • Leucocyte depletion of the blood supply: How will patients benefit?
    • Williamson LM. Leucocyte depletion of the blood supply: How will patients benefit? Br J Haematol 2000; 110: 256-72.
    • (2000) Br. J. Haematol. , vol.110 , pp. 256-272
    • Williamson, L.M.1
  • 2
    • 0032018136 scopus 로고    scopus 로고
    • Guidelines on the clinical use of leucocyte-depleted blood components. British Committee for Standards in Haematology. Blood Transfusion Task Force
    • Guidelines on the clinical use of leucocyte-depleted blood components. British Committee for Standards in Haematology. Blood Transfusion Task Force. Transfus Med 1998; 8: 59-71.
    • (1998) Transfus. Med. , vol.8 , pp. 59-71
  • 3
    • 0004106491 scopus 로고    scopus 로고
    • Guide to the preparation, use and quality assurance of blood components
    • Council of Europe. Council of Europe publishing, Strasbourg
    • Council of Europe. (2000) Guide to the preparation, use and quality assurance of blood components. Council of Europe publishing, Strasbourg.
    • (2000)
  • 4
    • 0141905530 scopus 로고    scopus 로고
    • Pre-Storage Leukocyte Reduction of Whole Blood and Blood Components Intended for Transfusion
    • Food and Drug Administration
    • Food and Drug Administration. (2001) Pre-Storage Leukocyte Reduction of Whole Blood and Blood Components Intended for Transfusion. http://www.fda.gov/cber/gdlns/preleuk.htm#ivb3
    • (2001)
  • 5
    • 0141974570 scopus 로고    scopus 로고
    • Enumeration of absolute counts using immunophenotypic techniques
    • John Wiley & Sons, New York, USA
    • Mandy F, Brando B. Enumeration of absolute counts using immunophenotypic techniques. In: Current Protocols in Cytometry 2000, p. 6.8.1-6.8.26. John Wiley & Sons, New York, USA.
    • (2000) Current Protocols in Cytometry
    • Mandy, F.1    Brando, B.2
  • 7
    • 0035677045 scopus 로고    scopus 로고
    • Comparison of five platforms for enumeration of residual leukocytes in leukoreduced blood components
    • for the Dutch Working Party "Universal Leukoreduction - Leukocyte Counting"
    • van der Meer PF, Gratama JW, van Delden CJ, et al for the Dutch Working Party "Universal Leukoreduction - Leukocyte Counting". Comparison of five platforms for enumeration of residual leukocytes in leukoreduced blood components. Br J Haematol 2001; 115: 953-62.
    • (2001) Br. J. Haematol. , vol.115 , pp. 953-962
    • van der Meer, P.F.1    Gratama, J.W.2    van Delden, C.J.3
  • 8
    • 0034958827 scopus 로고    scopus 로고
    • Low level leucocyte counting: A critical variable in the validation of leucodepleted blood transfusion components as highlighted by an external quality assessment study
    • Barnett D, Goodfellow KJ, Ginnever J. Low level leucocyte counting: a critical variable in the validation of leucodepleted blood transfusion components as highlighted by an external quality assessment study. Clin Lab Haematol 2001; 23: 43-5.
    • (2001) Clin. Lab. Haematol. , vol.23 , pp. 43-45
    • Barnett, D.1    Goodfellow, K.J.2    Ginnever, J.3
  • 9
    • 0036593725 scopus 로고    scopus 로고
    • The United Kingdom National External Quality Assessment Scheme and standardization strategy for use in residual WBC counting of WBC-reduced blood components
    • Goodfellow KJ, Storie I, Granger V, et al. The United Kingdom National External Quality Assessment Scheme and standardization strategy for use in residual WBC counting of WBC-reduced blood components. Transfusion 2002; 42: 738-46.
    • (2002) Transfusion , vol.42 , pp. 738-746
    • Goodfellow, K.J.1    Storie, I.2    Granger, V.3
  • 10
    • 0037107774 scopus 로고    scopus 로고
    • Interpretation of atypical patterns encountered when using a flow cyometry-based method to detect residual leukocytes in leukoreduced red blood cell components
    • Janatpour K, Paglieroni TG, Schuller L, Foley K, Rizzardo T, Holland PV. Interpretation of atypical patterns encountered when using a flow cyometry-based method to detect residual leukocytes in leukoreduced red blood cell components. Cytometry (Clinical Cytometry) 2002; 50: 254-60.
    • (2002) Cytometry (Clinical Cytometry) , vol.50 , pp. 254-260
    • Janatpour, K.1    Paglieroni, T.G.2    Schuller, L.3    Foley, K.4    Rizzardo, T.5    Holland, P.V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.