메뉴 건너뛰기




Volumn 225, Issue 2-3, 2003, Pages 271-283

Safety design maps: An early evaluation of safety to support reactor design

Author keywords

[No Author keywords available]

Indexed keywords

HEAT SINKS; OPTIMIZATION; PRESSURE VESSELS;

EID: 0141951954     PISSN: 00295493     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0029-5493(03)00158-4     Document Type: Article
Times cited : (7)

References (21)
  • 1
    • 0141891523 scopus 로고
    • Possibility of a pressurized water reactor concept with highly inherent heat removal following capability
    • Araya F., Murao Y. Possibility of a pressurized water reactor concept with highly inherent heat removal following capability. J. Nucl. Sci. Technol. 32:1995;339-350.
    • (1995) J. Nucl. Sci. Technol. , vol.32 , pp. 339-350
    • Araya, F.1    Murao, Y.2
  • 2
    • 0029344937 scopus 로고
    • A parametric study of the steady-state operational characteristics of the Ohio State University natural circulation, indirect-cycle, inherently safe boiling water reactor
    • Aybar H.S., Aldemir T., Christensen R.N. A parametric study of the steady-state operational characteristics of the Ohio State University natural circulation, indirect-cycle, inherently safe boiling water reactor. Nucl. Technol. 111:1995;1-22.
    • (1995) Nucl. Technol. , vol.111 , pp. 1-22
    • Aybar, H.S.1    Aldemir, T.2    Christensen, R.N.3
  • 4
    • 0022206823 scopus 로고
    • Anticipated transient without SCRAM
    • Hemisphere Publishing, New York
    • Burchill, W.E., 1985. Anticipated transient without SCRAM. In: Guidebook to Light-Water Reactor Safety Analysis. Hemisphere Publishing, New York, pp. 311-358.
    • (1985) Guidebook to Light-water Reactor Safety Analysis , pp. 311-358
    • Burchill, W.E.1
  • 6
    • 0141891524 scopus 로고
    • A critical heat flux correlation for advanced pressurized light water reactor application
    • Donne, M.D., Hame, W., 1982. A critical heat flux correlation for advanced pressurized light water reactor application. EPRI Report.
    • (1982) EPRI Report
    • Donne, M.D.1    Hame, W.2
  • 10
    • 0024067798 scopus 로고
    • On the safety goal for small reactors
    • Gremm O. On the safety goal for small reactors. Nucl. Eng. Des. 109:1988;329-333.
    • (1988) Nucl. Eng. Des. , vol.109 , pp. 329-333
    • Gremm, O.1
  • 12
    • 0030196044 scopus 로고
    • Anticipated transient without SCRAM analysis of the simplified boiling water reactor following main steam isolation valve closure with boron injection
    • Khan H.J., Cheng H.S., Rohatgi U.S. Anticipated transient without SCRAM analysis of the simplified boiling water reactor following main steam isolation valve closure with boron injection. Nucl. Technol. 115:1995;22-34.
    • (1995) Nucl. Technol. , vol.115 , pp. 22-34
    • Khan, H.J.1    Cheng, H.S.2    Rohatgi, U.S.3
  • 13
    • 24544457647 scopus 로고
    • ATWS analyses for VVER-91 concept by the SMARTA code
    • Kyrki-Rajamäki R., Mierrinen J. ATWS analyses for VVER-91 concept by the SMARTA code. Trans. Am. Nucl. Soc. 67:1993;203-207.
    • (1993) Trans. Am. Nucl. Soc. , vol.67 , pp. 203-207
    • Kyrki-Rajamäki, R.1    Mierrinen, J.2
  • 14
    • 0026941136 scopus 로고
    • A long term MAAP 3,0B analysis of a severe anticipated transient without SCRAM accident in a boiling water reactor
    • Lee M., Wu E.C. A long term MAAP 3,0B analysis of a severe anticipated transient without SCRAM accident in a boiling water reactor. Nucl. Technol. 100:1992;39-51.
    • (1992) Nucl. Technol. , vol.100 , pp. 39-51
    • Lee, M.1    Wu, E.C.2
  • 16
    • 0011200316 scopus 로고
    • RETRAN-02: A program for transient thermal-hydraulic analysis of complex fluid flow systems
    • EPRI
    • McFadden, J.H., Narum, R.E., et al., 1992. RETRAN-02: a program for transient thermal-hydraulic analysis of complex fluid flow systems. Code Manual, EPRI.
    • (1992) Code Manual
    • McFadden, J.H.1    Narum, R.E.2
  • 17
    • 0027624579 scopus 로고
    • Best-estimate methodology for analysis of anticipated transient without SCRAM in pressurized water reactors
    • Rebollo L. Best-estimate methodology for analysis of anticipated transient without SCRAM in pressurized water reactors. Nucl. Technol. 103:1992;49-66.
    • (1992) Nucl. Technol. , vol.103 , pp. 49-66
    • Rebollo, L.1
  • 18
    • 0027623629 scopus 로고
    • A realistic anticipated transient without SCRAM. Evaluation of the Zorita nuclear power plant
    • Rebollo L. A realistic anticipated transient without SCRAM. Evaluation of the Zorita nuclear power plant. Nucl. Technol. 103:1993;122-129.
    • (1993) Nucl. Technol. , vol.103 , pp. 122-129
    • Rebollo, L.1
  • 19
    • 0030109162 scopus 로고
    • Use of the CHINSHAN plant analyzer for analysis of a main steam isolation valve closure anticipated transient without SCRAM
    • Wang S.J., Chang S.H. Use of the CHINSHAN plant analyzer for analysis of a main steam isolation valve closure anticipated transient without SCRAM. Nucl. Technol. 113:1995;280-289.
    • (1995) Nucl. Technol. , vol.113 , pp. 280-289
    • Wang, S.J.1    Chang, S.H.2
  • 21
    • 0026942879 scopus 로고
    • Transient analysis of the MSIV-ATWS in a 1000-MW (thermal) BWR-4
    • Zimmermann M.A. Transient analysis of the MSIV-ATWS in a 1000-MW (thermal) BWR-4. Nucl. Technol. 100:1992;184-192.
    • (1992) Nucl. Technol. , vol.100 , pp. 184-192
    • Zimmermann, M.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.