메뉴 건너뛰기




Volumn 13, Issue 3, 2003, Pages 212-222

Effectiveness of duct cleaning methods on newly installed duct surfaces

Author keywords

Brushing; Cleaning force; Compressed air cleaning; Duct; Dust; Oil residues

Indexed keywords

AIR CLEANERS; DUST; LABORATORIES; METAL CLEANING; PRESSURE VESSELS;

EID: 0141941256     PISSN: 09056947     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0668.2003.00179.x     Document Type: Article
Times cited : (17)

References (21)
  • 3
    • 0345720850 scopus 로고    scopus 로고
    • Processing oil residues on new HVAC-components: The addiction of manufacturing technique to the amount of components oil residue
    • Seppänen, O. and Säteri, J. (eds) Espoo, The 6th Healthy Buildings Conference.
    • Asikainen, V. and Pasanen, P. (2000) Processing oil residues on new HVAC-components: the addiction of manufacturing technique to the amount of components oil residue. In: Seppänen, O. and Säteri, J. (eds) Proceedings of Healthy Buildings 2000 Conference, Espoo, The 6th Healthy Buildings Conference. Vol. 2, pp. 707-712.
    • (2000) Proceedings of Healthy Buildings 2000 Conference , vol.2 , pp. 707-712
    • Asikainen, V.1    Pasanen, P.2
  • 4
    • 0345720849 scopus 로고    scopus 로고
    • The Effect of Ventilation Duct Material and Dust Accumulation on Perceived Supply Air Quality
    • Seppänen, O. and Säteri, J. (eds.) Espoo, The 6th Healthy Buildings Conference
    • Björkroth, M. and Asikainen, V. (2000) The Effect of Ventilation Duct Material and Dust Accumulation on Perceived Supply Air Quality. In: Seppänen, O. and Säteri, J. (eds.) Proceedings of Healthy Buildings 2000 Conference. Espoo, The 6th Healthy Buildings Conference, Vol. 2, pp. 157-162.
    • (2000) Proceedings of Healthy Buildings 2000 Conference , vol.2 , pp. 157-162
    • Björkroth, M.1    Asikainen, V.2
  • 7
    • 0345720854 scopus 로고    scopus 로고
    • Guide to Good Practice Cleanliness of Ventilation Systems. Heating and Ventilating Contractors' Association, London, HVCA Publications, (TR/17)
    • HVCA (1998) Cleanliness of Ventilation Systems, Guide to Good Practice Cleanliness of Ventilation Systems. Heating and Ventilating Contractors' Association, London, HVCA Publications, (TR/17).
    • (1998) Cleanliness of Ventilation Systems
  • 8
    • 0344858018 scopus 로고    scopus 로고
    • Cleaning Technology of the Air Handling System
    • Raw, G., Aizlewood, C., Warren, P. (eds) Edinburgh, the 8th International Conference on Indoor Air Quality and Climate
    • Holopainen, R., Palonen, J. and Seppänen, O. (1999) Cleaning Technology of the Air Handling System. In: Raw, G., Aizlewood, C., Warren, P. (eds) Proceedings of Indoor Air 99, Edinburgh, the 8th International Conference on Indoor Air Quality and Climate, Vol. 3, pp. 97-102.
    • (1999) Proceedings of Indoor Air 99 , vol.3 , pp. 97-102
    • Holopainen, R.1    Palonen, J.2    Seppänen, O.3
  • 10
    • 0344426175 scopus 로고    scopus 로고
    • Dust Deposit Evaluation of Air Conditioning Duct
    • Yoshizawa, S., Kimura, K., Ikeda, K., Tanabe, S. and Iwata, T. (eds.) Nagoya, The 7th International Conference on Indoor Air Quality and Climate
    • Ito H., Yoshizawa S., Kumagai K., Shizaka K., Kimura K., Ishikawa K. and Iwata T. (1996) Dust Deposit Evaluation of Air Conditioning Duct. In: Yoshizawa, S., Kimura, K., Ikeda, K., Tanabe, S. and Iwata, T. (eds.) Proceedings of Indoor Air'96, Nagoya, The 7th International Conference on Indoor Air Quality and Climate, Vol. 3, pp. 965-970.
    • (1996) Proceedings of Indoor Air'96 , vol.3 , pp. 965-970
    • Ito, H.1    Yoshizawa, S.2    Kumagai, K.3    Shizaka, K.4    Kimura, K.5    Ishikawa, K.6    Iwata, T.7
  • 12
    • 85153270810 scopus 로고    scopus 로고
    • Test Method for the Tendency of HVAC-Components to Accumulate Dirt on Surfaces
    • Seppä nen, O. and Säteri, J. (eds) Espoo, The 6th Healthy Buildings Conference
    • Kovanen, K. (2000) Test Method for the Tendency of HVAC-Components to Accumulate Dirt on Surfaces. In: Seppä nen, O. and Säteri, J. (eds) Proceedings of Healthy Buildings 2000 Conference, Espoo, The 6th Healthy Buildings Conference, Vol. 2, pp. 181-186.
    • (2000) Proceedings of Healthy Buildings 2000 Conference , vol.2 , pp. 181-186
    • Kovanen, K.1
  • 13
    • 0345720851 scopus 로고    scopus 로고
    • Evaluating residential air duct cleaning and ia: Results of a field study conducted in nine single family dwellings
    • Woods, J.E., Grimsrud, D.T. and Boschi, N. (eds) Washington DC, USA, The 5th Healthy Buildings Conference
    • Kulp, R., Fortmann, R., Gentry, C., Van-Osdell, D., Foarde, K., Hebert, T., Krell, R. and Cochrane, C. (1997) Evaluating residential air duct cleaning and ia: results of a field study conducted in nine single family dwellings. In: Woods, J.E., Grimsrud, D.T. and Boschi, N. (eds) Proceedings of Healthy Buildings/IAQ'97, Washington DC, USA, The 5th Healthy Buildings Conference, Vol. 1, pp. 605-610.
    • (1997) Proceedings of Healthy Buildings/IAQ'97 , vol.1 , pp. 605-610
    • Kulp, R.1    Fortmann, R.2    Gentry, C.3    Van-Osdell, D.4    Foarde, K.5    Hebert, T.6    Krell, R.7    Cochrane, C.8
  • 14
    • 0345289265 scopus 로고    scopus 로고
    • Protecting ventilation ducts and accessories against dirt during the construction work
    • Seppänen, O. and Säteri, J.(eds.) Espoo, The 6th Healthy Buildings Conference
    • Luoma, M. (2000) Protecting ventilation ducts and accessories against dirt during the construction work. In: Seppänen, O. and Säteri, J.(eds.) Proceedings of Healthy Buildings 2000 Conference, Espoo, The 6th Healthy Buildings Conference, Vol. 2, pp. 145-150.
    • (2000) Proceedings of Healthy Buildings 2000 Conference , vol.2 , pp. 145-150
    • Luoma, M.1
  • 15
    • 0003725926 scopus 로고
    • An Industry Standard Developed by the National Air Duct Cleaners Association. Washington, DC, NADCA
    • NADCA (1992) Mechanical Cleaning of Non-Porous Air Conveyance System Components, An Industry Standard Developed by the National Air Duct Cleaners Association. Washington, DC, NADCA, 1992-01.
    • (1992) Mechanical Cleaning of Non-Porous Air Conveyance System Components , pp. 1992-2001
  • 16
    • 0002766988 scopus 로고
    • Hygienic aspects of processing oil residues in ventilation ducts
    • Pasanen, P., Pasanen, A.L. and Kalliokoski, P. (1995) Hygienic aspects of processing oil residues in ventilation ducts, Indoor Air, 5, 62-68.
    • (1995) Indoor Air , vol.5 , pp. 62-68
    • Pasanen, P.1    Pasanen, A.L.2    Kalliokoski, P.3
  • 18
    • 0344858017 scopus 로고    scopus 로고
    • Verification of cleanliness of HVAC-systems
    • Loyd, S. (ed.) The International Ventilation Hygiene Conference and Exhibition, Birmingham, UK
    • Pasanen P. (1999) Verification of cleanliness of HVAC-systems. In: Loyd, S. (ed.) Proceedings of VHExCo99. The International Ventilation Hygiene Conference and Exhibition, Birmingham, UK.
    • (1999) Proceedings of VHExCo99
    • Pasanen, P.1
  • 19
    • 0345720852 scopus 로고    scopus 로고
    • Storage and processing oil contamination on new HVAC-Components: Development of measuring methods
    • Raw, G., Aizlewood, C. and Warren, P. (eds) Edinburgh, The 8th International Conference on Indoor Air Quality and Climate
    • Pasanen, P., Asikainen, V. and Liesivuori, J. (1999) Storage and processing oil contamination on new HVAC-Components: development of measuring methods. In: Raw, G., Aizlewood, C. and Warren, P. (eds) Proceedings of Indoor Air 99, Edinburgh, The 8th International Conference on Indoor Air Quality and Climate, Vol. 5, pp. 19-24.
    • (1999) Proceedings of Indoor Air 99 , vol.5 , pp. 19-24
    • Pasanen, P.1    Asikainen, V.2    Liesivuori, J.3
  • 20
    • 0000821432 scopus 로고    scopus 로고
    • Design and calibration of a simple instrument for measuring dust on surfaces in the indoor environment
    • Schneider, T., Kildesø, J., Petersen, O.H., Kloch, N.P. and Løbner, T. (1996) Design and calibration of a simple instrument for measuring dust on surfaces in the indoor environment, Indoor Air, 6, 204-210.
    • (1996) Indoor Air , vol.6 , pp. 204-210
    • Schneider, T.1    Kildesø, J.2    Petersen, O.H.3    Kloch, N.P.4    Løbner, T.5
  • 21
    • 0029907240 scopus 로고    scopus 로고
    • The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. Part Three: Associations between environmental factors and self-reported health conditions
    • Sieber, W.K., Stayner, L.T., Malkin, R., Petersen, M.R., Mendell, M.J., Wallingford, K.M., Crandall, M.S., Wilox, T.G. and Reed, L. (1996) The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. Part Three: Associations between environmental factors and self-reported health conditions, Appl. Occup. Environ. Hyg., 11(12), 1387-1392.
    • (1996) Appl. Occup. Environ. Hyg. , vol.11 , Issue.12 , pp. 1387-1392
    • Sieber, W.K.1    Stayner, L.T.2    Malkin, R.3    Petersen, M.R.4    Mendell, M.J.5    Wallingford, K.M.6    Crandall, M.S.7    Wilox, T.G.8    Reed, L.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.