메뉴 건너뛰기




Volumn 4, Issue 2, 2003, Pages 124-129

Detection of hepatic VX2 tumors in rabbits: Comparison of conventional US and phase-inversion harmonic US during the liver-specific late phase of contrast enhancement

Author keywords

Animals, liver neoplasms; Liver neoplasms, US; Ultrasound (US), contrast media; Ultrasound (US), harmonic study

Indexed keywords

ANIMAL TISSUE; ARTICLE; B SCAN; BOLUS INJECTION; CONTROLLED STUDY; ECHOGRAPHY; IMAGING SYSTEM; INTERMETHOD COMPARISON; LIVER PARENCHYMA; LIVER TUMOR; NONHUMAN; PATHOLOGICAL ANATOMY; RABBIT; TUMOR VOLUME; ULTRASOUND; ANIMAL; CANCER TRANSPLANTATION; MALE; METHODOLOGY;

EID: 0141939630     PISSN: 12296929     EISSN: None     Source Type: Journal    
DOI: 10.3348/kjr.2003.4.2.124     Document Type: Article
Times cited : (2)

References (25)
  • 2
    • 0020529073 scopus 로고
    • Computed tomography, ultrasound, and scintigraphy of the liver in patients with colon or breast carcinoma: A prospective comparison
    • Alderson PO, Adams DF, McNeil BJ, et al. Computed tomography, ultrasound, and scintigraphy of the liver in patients with colon or breast carcinoma: a prospective comparison. Radiology 1983;149:225-230
    • (1983) Radiology , vol.149 , pp. 225-230
    • Alderson, P.O.1    Adams, D.F.2    McNeil, B.J.3
  • 3
    • 0026747696 scopus 로고
    • Detection of liver metastases from colorectal cancer: Comparison of intraoperative ultrasound and CT during arterial portography
    • Soyer PH, Levesque M, Elias D, Zeitoun G, Roche A. Detection of liver metastases from colorectal cancer: comparison of intraoperative ultrasound and CT during arterial portography. Radiology 1992;183:541-544
    • (1992) Radiology , vol.183 , pp. 541-544
    • Soyer, P.H.1    Levesque, M.2    Elias, D.3    Zeitoun, G.4    Roche, A.5
  • 4
    • 0026095215 scopus 로고
    • Detection of hepatic masses in patients with carcinoma: Comparative sensitivities of sonography, CT, and MR imaging
    • Wernecke K, Rummeny E, Bongartz G, et al. Detection of hepatic masses in patients with carcinoma: comparative sensitivities of sonography, CT, and MR imaging. AJR Am J Roentgenol 1991;157:731-739
    • (1991) AJR Am J Roentgenol , vol.157 , pp. 731-739
    • Wernecke, K.1    Rummeny, E.2    Bongartz, G.3
  • 5
    • 0024453592 scopus 로고
    • Prospective comparison of preoperative imaging and intraoperative ultrasonography in the detection of liver tumors
    • Clarke MP, Kane RA, Steele G Jr, et al. Prospective comparison of preoperative imaging and intraoperative ultrasonography in the detection of liver tumors. Surgery 1989;106:849-855
    • (1989) Surgery , vol.106 , pp. 849-855
    • Clarke, M.P.1    Kane, R.A.2    Steele Jr., G.3
  • 6
    • 0027218264 scopus 로고
    • Detection of hepatic metastases in colorectal cancer: A prospective study of laboratory and imaging methods
    • Ohlsson B, Tranberg KG, Lundstedt C, Ekberg H, Hederstrom E. Detection of hepatic metastases in colorectal cancer: a prospective study of laboratory and imaging methods. Eur J Surg 1993;159:275-281
    • (1993) Eur J Surg , vol.159 , pp. 275-281
    • Ohlsson, B.1    Tranberg, K.G.2    Lundstedt, C.3    Ekberg, H.4    Hederstrom, E.5
  • 7
    • 0025167971 scopus 로고
    • Liver tumor imaging: Current concepts
    • Ferrucci JT. Liver tumor imaging: current concepts. AJR Am J Roentgenol 1990;155:473-484
    • (1990) AJR Am J Roentgenol , vol.155 , pp. 473-484
    • Ferrucci, J.T.1
  • 8
    • 0033980281 scopus 로고    scopus 로고
    • Pulse-inversion imaging of liver blood flow: Improved method for characterizing focal masses with microbubble contrast
    • Burns PN, Wilson SR, Simpson DH. Pulse-inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast. Invest Radiol 2000;35:58-71
    • (2000) Invest Radiol , vol.35 , pp. 58-71
    • Burns, P.N.1    Wilson, S.R.2    Simpson, D.H.3
  • 9
    • 0034067847 scopus 로고    scopus 로고
    • Harmonic hepatic US with microbubble contrast agent: Initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastases
    • Wilson SR, Burns PN, Muradali D, Wilson JA, Lai X. Harmonic hepatic US with microbubble contrast agent: initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastases. Radiology 2000;215:153-161
    • (2000) Radiology , vol.215 , pp. 153-161
    • Wilson, S.R.1    Burns, P.N.2    Muradali, D.3    Wilson, J.A.4    Lai, X.5
  • 11
    • 0032586125 scopus 로고    scopus 로고
    • The use of stimulated acoustic emission to image a late liver-specific phase of Levovist: An investigation in normal volunteers and in patients with and without liver disease
    • Blomley MJK, Albrecht T, Cosgrove DO, et al. The use of stimulated acoustic emission to image a late liver-specific phase of Levovist: an investigation in normal volunteers and in patients with and without liver disease. Ultrasound Med Biol 1999;25: 1341-1352
    • (1999) Ultrasound Med Biol , vol.25 , pp. 1341-1352
    • Blomley, M.J.K.1    Albrecht, T.2    Cosgrove, D.O.3
  • 12
    • 0032948352 scopus 로고    scopus 로고
    • Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SHU 508A: Early experience
    • Blomley MJK, Albrecht T, Cosgrove DO, et al. Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SHU 508A: early experience. Radiology 1999;210:409-416
    • (1999) Radiology , vol.210 , pp. 409-416
    • Blomley, M.J.K.1    Albrecht, T.2    Cosgrove, D.O.3
  • 13
    • 0033771486 scopus 로고    scopus 로고
    • Gray-scale second harmonic imaging of acoustic emission signals improves detection of liver tumors in rabbits
    • Forsberg F, Liu JB, Merton DA, Rawool NM, Johnson DK, Goldberg BB. Gray-scale second harmonic imaging of acoustic emission signals improves detection of liver tumors in rabbits. J Ultrasound Med 2000;19:557-563
    • (2000) J Ultrasound Med , vol.19 , pp. 557-563
    • Forsberg, F.1    Liu, J.B.2    Merton, D.A.3    Rawool, N.M.4    Johnson, D.K.5    Goldberg, B.B.6
  • 14
    • 0036186883 scopus 로고    scopus 로고
    • Hepatic tumor detection: MR imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase
    • Forsberg F, Piccoli CW, Rawool NM, Merton DA, Mitchell DG, Goldberg BB. Hepatic tumor detection: MR imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase. Radiology 2002;222:824-829
    • (2002) Radiology , vol.222 , pp. 824-829
    • Forsberg, F.1    Piccoli, C.W.2    Rawool, N.M.3    Merton, D.A.4    Mitchell, D.G.5    Goldberg, B.B.6
  • 15
    • 0033932353 scopus 로고    scopus 로고
    • B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: Initial experience in humans
    • Albrecht T, Hoffmann CW, Schettler S, et al. B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: initial experience in humans. Radiology 2000;216:273-278
    • (2000) Radiology , vol.216 , pp. 273-278
    • Albrecht, T.1    Hoffmann, C.W.2    Schettler, S.3
  • 16
    • 0035045309 scopus 로고    scopus 로고
    • Phase-inversion sonography during the liver-specific late phase of contrast enhancement: Improved detection of liver metastases
    • Albrecht T, Hoffmann CW, Schmitz SA, et al. Phase-inversion sonography during the liver-specific late phase of contrast enhancement: improved detection of liver metastases. AJR Am J Roentgenol 2001;176:1191-1198
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 1191-1198
    • Albrecht, T.1    Hoffmann, C.W.2    Schmitz, S.A.3
  • 18
    • 0020553412 scopus 로고
    • Effect of occult hepatic metastases on survival after curative resection for colorectal carcinoma
    • Finlay IG, McArdle CS. Effect of occult hepatic metastases on survival after curative resection for colorectal carcinoma. Gastroenterology 1983;85:596-599
    • (1983) Gastroenterology , vol.85 , pp. 596-599
    • Finlay, I.G.1    McArdle, C.S.2
  • 19
    • 0002458318 scopus 로고
    • Treatment of metastatic liver tumors
    • Rosenberg SA, ed. Philadelphia: Lippincott
    • Hughes KS, Sugarbaker PH. Treatment of metastatic liver tumors. In: Rosenberg SA, ed. Surgical cure of metastatic cancer. Philadelphia: Lippincott, 1987:125-164
    • (1987) Surgical Cure of Metastatic Cancer , pp. 125-164
    • Hughes, K.S.1    Sugarbaker, P.H.2
  • 20
    • 0002601064 scopus 로고    scopus 로고
    • Acoustically stimulated microbubbles in diagnostic ultrasound: Properties and implications for diagnostic use
    • Nanda N, Schlief R, Goldberg BB, eds. London: Kluwer
    • Bauer A, Schlief R, Zomack M, Urbank A, Niendorf HP. Acoustically stimulated microbubbles in diagnostic ultrasound: properties and implications for diagnostic use. In: Nanda N, Schlief R, Goldberg BB, eds. Advances in echo imaging using contrast enhancement, 2nd ed. London: Kluwer, 1997:669-684
    • (1997) Advances in Echo Imaging Using Contrast Enhancement, 2nd Ed. , pp. 669-684
    • Bauer, A.1    Schlief, R.2    Zomack, M.3    Urbank, A.4    Niendorf, H.P.5
  • 21
    • 0033096935 scopus 로고    scopus 로고
    • Pulse-inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents
    • Simpson DH, Chin CT, Burns PN. Pulse-inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents. IEEE Trans Ultrason Ferroelec Freq Contr 1999;46:372-382
    • (1999) IEEE Trans Ultrason Ferroelec Freq Contr , vol.46 , pp. 372-382
    • Simpson, D.H.1    Chin, C.T.2    Burns, P.N.3
  • 23
    • 0031363435 scopus 로고    scopus 로고
    • Pulse-inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents
    • Simpson DH, Burns PN. Pulse-inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents. IEEE Ultrasonic Symposium 1997;1597-1600
    • (1997) IEEE Ultrasonic Symposium , pp. 1597-1600
    • Simpson, D.H.1    Burns, P.N.2
  • 24
    • 0036181049 scopus 로고    scopus 로고
    • Initial observations on the effect of irradiation on the liver-specific uptake of Levovist
    • Quaia E, Blomley MJK, Patel S, et al. Initial observations on the effect of irradiation on the liver-specific uptake of Levovist. Eur J Radiol 2002;41:192-199
    • (2002) Eur J Radiol , vol.41 , pp. 192-199
    • Quaia, E.1    Blomley, M.J.K.2    Patel, S.3
  • 25
    • 0029740035 scopus 로고    scopus 로고
    • Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: Contrast-injection protocol and optimal timing
    • Mitsuzaki K, Yamashita Y, Ogata I, et al. Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. AJR Am J Roentgenol 1996;167:753-757
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 753-757
    • Mitsuzaki, K.1    Yamashita, Y.2    Ogata, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.