메뉴 건너뛰기




Volumn 42, Issue 28, 2003, Pages 5759-5764

Efficient characterization of regional mesenteric blood flow by use of laser speckle imaging

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ARTICLE; DIAGNOSTIC IMAGING; LASER; MALE; RAT; SPLANCHNIC BLOOD FLOW; THEORETICAL MODEL; WISTAR RAT;

EID: 0141925184     PISSN: 1559128X     EISSN: 21553165     Source Type: Journal    
DOI: 10.1364/AO.42.005759     Document Type: Article
Times cited : (38)

References (30)
  • 2
    • 0028895523 scopus 로고
    • Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes
    • K. Mithofer, J. Schmidt, M. M. Gebhard, H. J. Buhr, C. Her-farth, and E. Klar, “Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes,” Micro-vasc. Res. 49, 33-36 (1995).
    • (1995) Micro-Vasc. Res. , vol.49 , pp. 33-36
    • Mithofer, K.1    Schmidt, J.2    Gebhard, M.M.3    Buhr, H.J.4    Her-Farth, C.5    Klar, E.6
  • 3
    • 0032807885 scopus 로고    scopus 로고
    • Pharmacological evaluation of a new laser blood flowmeter for measuring coronary blood flow, assessed in the canine isolated, blood-perfused ventricular tissue preparation in comparison with an electromagnetic flowmeter
    • S. Atsushi, T. Shunji, and H. Keitaro, “Pharmacological evaluation of a new laser blood flowmeter for measuring coronary blood flow, assessed in the canine isolated, blood-perfused ventricular tissue preparation in comparison with an electromagnetic flowmeter,” Jpn. J. Pharmacol. 80, 263-266 (1999).
    • (1999) Jpn. J. Pharmacol. , vol.80 , pp. 263-266
    • Atsushi, S.1    Shunji, T.2    Keitaro, H.3
  • 4
    • 84975624012 scopus 로고
    • Laser Doppler velocimetry in blood and multiply scattering fluids: Theory
    • M. D. Stern, “Laser Doppler velocimetry in blood and multiply scattering fluids: theory,” Appl. Opt. 24, 1968-1986 (1985).
    • (1985) Appl. Opt. , vol.24 , pp. 1968-1986
    • Stern, M.D.1
  • 5
    • 0011948258 scopus 로고    scopus 로고
    • Speckle and Doppler methods of blood and lymph flow monitoring
    • V. V. Tuchin, ed. (SPIE Press, Bellingham, Wash
    • E. I. Galanzha, G. E. Brill, Y. Aizu, S. S. Ulynov, and V. V. Tuchin, “Speckle and Doppler methods of blood and lymph flow monitoring,” in Handbook of Optical Biomedical Diagnostics, V. V. Tuchin, ed. (SPIE Press, Bellingham, Wash., 2002), pp. 881-937.
    • (2002) Handbook of Optical Biomedical Diagnostics , pp. 881-937
    • Galanzha, E.I.1    Brill, G.E.2    Aizu, Y.3    Ulynov, S.S.4    Tuchin, V.V.5
  • 7
    • 0013331279 scopus 로고    scopus 로고
    • Speckle technologies for monitoring and imaging of tissues and tissuelike phantoms
    • V. V. Tuchin, ed. (SPIE Press, Bellingham, Wash
    • D. A. Zimnyakov, J. D. Briers, and V. V. Tuchin, “Speckle technologies for monitoring and imaging of tissues and tissuelike phantoms,” in Handbook of Optical Biomedical Diagnostics, V. V. Tuchin, ed. (SPIE Press, Bellingham, Wash., 2002), pp. 987-1036.
    • (2002) Handbook of Optical Biomedical Diagnostics , pp. 987-1036
    • Zimnyakov, D.A.1    Briers, J.D.2    Tuchin, V.V.3
  • 8
    • 0033378522 scopus 로고    scopus 로고
    • Laser Doppler imaging of activation-flow coupling in the rat somatosensory cortex
    • B. M. Ances, J. H. Greenberg, and J. A. Detre, “Laser Doppler imaging of activation-flow coupling in the rat somatosensory cortex,” Neuroimage 10, 716-723 (1999).
    • (1999) Neuroimage , vol.10 , pp. 716-723
    • Ances, B.M.1    Greenberg, J.H.2    Detre, J.A.3
  • 9
    • 0019579052 scopus 로고
    • Flow visualization by means of single-exposure speckle photography
    • A. F. Fercher and J. D. Briers, “Flow visualization by means of single-exposure speckle photography,” Opt. Commun. 37, 326-329 (1981).
    • (1981) Opt. Commun. , vol.37 , pp. 326-329
    • Fercher, A.F.1    Briers, J.D.2
  • 10
    • 0000823973 scopus 로고    scopus 로고
    • Laser speckle contrast analysis (LASCA): A nonscanning, full-field technique for monitoring capillary blood flow
    • J. D. Briers and S. Webster, “Laser speckle contrast analysis (LASCA): A nonscanning, full-field technique for monitoring capillary blood flow,” J. Biomed. Opt. 1, 174-179 (1996).
    • (1996) J. Biomed. Opt. , vol.1 , pp. 174-179
    • Briers, J.D.1    Webster, S.2
  • 11
    • 0028397638 scopus 로고
    • Measuring the steady-state value and the dynamics of the skin blood flow using the non-contact laser speckle method
    • B. Ruth, “Measuring the steady-state value and the dynamics of the skin blood flow using the non-contact laser speckle method,” Med. Eng. Phys. 16, 105-111 (1994).
    • (1994) Med. Eng. Phys. , vol.16 , pp. 105-111
    • Ruth, B.1
  • 12
    • 0033864774 scopus 로고    scopus 로고
    • Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser Doppler flowmetry
    • K. Yaoeda, M. Shirakashi, S. Funaki, H. Funaki, T. Nakatsue, and H. Abe, “Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser Doppler flowmetry,” Am. J. Ophthalmol. 129, 734-739 (2000).
    • (2000) Am. J. Ophthalmol. , vol.129 , pp. 734-739
    • Yaoeda, K.1    Shirakashi, M.2    Funaki, S.3    Funaki, H.4    Nakatsue, T.5    Abe, H.6
  • 13
    • 0036171973 scopus 로고    scopus 로고
    • Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
    • H. Bolay, U. Reuter, A. K. Dunn, Z. Huang, D. A. Boas, and A. M. Moskowitz, “Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model,” Nat. Med. 8, 136 -142 (2002).
    • (2002) Nat. Med. , vol.8
    • Bolay, H.1    Reuter, U.2    Dunn, A.K.3    Huang, Z.4    Boas, D.A.5    Moskowitz, A.M.6
  • 14
    • 0035358203 scopus 로고    scopus 로고
    • The application of zero-crossings of laser speckle for real-time monitoring of velocity of lymph flow
    • (in Chinese)
    • H. Y. Cheng, Q. M. Luo, S. Q. Zeng, L. Yao, A. J. Wang, and S. S. Ul’yanov, “The application of zero-crossings of laser speckle for real-time monitoring of velocity of lymph flow,” Space Med. Med. Eng. 14, 187-191 (2001) (in Chinese).
    • (2001) Space Med. Med. Eng. , vol.14 , pp. 187-191
    • Cheng, H.Y.1    Luo, Q.M.2    Zeng, S.Q.3    Yao, L.4    Wang, A.J.5    Ul’yanov, S.S.6
  • 16
    • 0142003099 scopus 로고    scopus 로고
    • Optical monitoring of the dynamic change of blood perfusion
    • (in Chinese)
    • H. Y. Cheng, D. Zhu, Q. M. Luo, S. Q. Zeng, Z. Wang, and S. S. Ul’yanov, “Optical monitoring of the dynamic change of blood perfusion,” Chin. J. Lasers 30, 668-705 (2003) (in Chinese).
    • (2003) Chin. J. Lasers , vol.30 , pp. 668-705
    • Cheng, H.Y.1    Zhu, D.2    Luo, Q.M.3    Zeng, S.Q.4    Wang, Z.5    Ul’yanov, S.S.6
  • 18
    • 0041345072 scopus 로고    scopus 로고
    • Optical assessment of tissue mechanics
    • V. V. Tuchin, ed. (SPIE Press, Bellingham, Wash
    • S. J. Kirkpatrick and D. D. Duncan, “Optical assessment of tissue mechanics,” in Handbook of Optical Biomedical Diagnostics, V. V. Tuchin, ed. (SPIE Press, Bellingham, Wash., 2002), pp. 1037-1084.
    • (2002) Handbook of Optical Biomedical Diagnostics , pp. 1037-1084
    • Kirkpatrick, S.J.1    Duncan, D.D.2
  • 19
    • 0001659693 scopus 로고
    • Some effects of target-induced scintillation on optical radar performance
    • J. W. Goodman, “Some effects of target-induced scintillation on optical radar performance,” Proc. IEEE 53, 1688-1700 (1965).
    • (1965) Proc. IEEE , vol.53 , pp. 1688-1700
    • Goodman, J.W.1
  • 20
    • 0019583049 scopus 로고
    • Model for laser Doppler measurements of blood flow in tissue
    • R. Bonner and R. Nossal, “Model for laser Doppler measurements of blood flow in tissue,” Appl. Opt. 20,2097-2107 (1981).
    • (1981) Appl. Opt. , vol.20 , pp. 2097-2107
    • Bonner, R.1    Nossal, R.2
  • 21
    • 0030858440 scopus 로고    scopus 로고
    • Lysophosphatidylcholine stimulates leukocyte rolling and adherence in rat mesenteric microvasculature
    • R. Scalia, T. Murohara, B. Campbell, A. Kaji, and A. M. Lefer, “Lysophosphatidylcholine stimulates leukocyte rolling and adherence in rat mesenteric microvasculature,” Am. J. Physiol. 272, H2584-H2590 (1997).
    • (1997) Am. J. Physiol. , vol.272 , pp. H2584-H2590
    • Scalia, R.1    Murohara, T.2    Campbell, B.3    Kaji, A.4    Lefer, A.M.5
  • 22
    • 0032735763 scopus 로고    scopus 로고
    • Capillary blood flow monitoring using laser speckle contrast analysis (LASCA)
    • J. D. Briers, G. Richarda, and X. W. He, “Capillary blood flow monitoring using laser speckle contrast analysis (LASCA),” J. Biomed. Opt. 4, 164-175 (1999).
    • (1999) J. Biomed. Opt. , vol.4 , pp. 164-175
    • Briers, J.D.1    Richarda, G.2    He, X.W.3
  • 23
    • 0028745833 scopus 로고
    • Fundamentals and applications of dynamic speckles induced by focused laser beam scattering
    • S. S. Ul’Yanov, D. A. Zimnyakov, and V. V. Tuchin, “Fundamentals and applications of dynamic speckles induced by focused laser beam scattering,” Opt. Eng. 33, 3189-3201 (1994).
    • (1994) Opt. Eng. , vol.33 , pp. 3189-3201
    • Ul’yanov, S.S.1    Zimnyakov, D.A.2    Tuchin, V.V.3
  • 24
    • 0032740019 scopus 로고    scopus 로고
    • Coherent optical techniques for the analysis of tissue structure and dynamics
    • V. V. Tuchin, “Coherent optical techniques for the analysis of tissue structure and dynamics,” J. Biomed. Opt. 4, 106-124 (1999).
    • (1999) J. Biomed. Opt. , vol.4 , pp. 106-124
    • Tuchin, V.V.1
  • 27
    • 0000099185 scopus 로고    scopus 로고
    • Laser Doppler and time-varying speckle: A reconciliation
    • J. D. Briers, “Laser Doppler and time-varying speckle: a reconciliation,” J. Opt. Soc. Am. 13, 345-350 (1996).
    • (1996) J. Opt. Soc. Am. , vol.13 , pp. 345-350
    • Briers, J.D.1
  • 29
    • 85010177291 scopus 로고    scopus 로고
    • A new method to investigate inflammatory responses to wear particles in vivo
    • H. Gebhard, S. P. Zysk, H. J. Refior, W. Plitz, K. Messmer, and A. Veihelmann, “A new method to investigate inflammatory responses to wear particles in vivo,” J. Vasc. Res. 39, S1 (2002).
    • (2002) J. Vasc. Res , vol.39 , pp. S1
    • Gebhard, H.1    Zysk, S.P.2    Refior, H.J.3    Plitz, W.4    Messmer, K.5
  • 30
    • 85010099121 scopus 로고    scopus 로고
    • A novel method for the intravital microscopic analysis of leukocyte transendothelial migration
    • C. M. Moser, T. Mempel, J. Hutter, W. M. Kuebler, and F. Krombach, “A novel method for the intravital microscopic analysis of leukocyte transendothelial migration,” J. Vasc. Res. 39, 42-50 (2002).
    • (2002) J. Vasc. Res. , vol.39 , pp. 42-50
    • Moser, C.M.1    Mempel, T.2    Hutter, J.3    Kuebler, W.M.4    Krombach, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.