Volumn 18, Issue 7 SUPPL. 1, 2003, Pages 48-54

In vivo and in vitro surface changes in a highly cross-linked polyethylene

Author keywords

Cross linked UHMWPE; Hip prosthesis; Surface modifications; Wear mechanisms

Indexed keywords

POLYETHYLENE;

EID: 0141924497     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(03)00303-6     Document Type: Conference Paper
Times cited : (19)

References (15)
  • 1
    • 0033861254 scopus 로고    scopus 로고
    • Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases
    • Herberts P, Malchau H: Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand 71:111, 2000
    • (2000) Acta Orthop Scand , vol.71 , pp. 111
    • Herberts, P.1    Malchau, H.2
  • 2
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert HG: Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 11:157, 1977
    • (1977) J Biomed Mater Res , vol.11 , pp. 157
    • Willert, H.G.1
  • 4
    • 0026881002 scopus 로고
    • Improvement of polyethylene by irradiation in artificial joints
    • Oonishi H, Takayama Y, Tsuji E: Improvement of polyethylene by irradiation in artificial joints. Radiat Phys Chem 39:495, 1992
    • (1992) Radiat Phys Chem , vol.39 , pp. 495
    • Oonishi, H.1    Takayama, Y.2    Tsuji, E.3
  • 5
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN: Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br 78B:280, 1996
    • (1996) J Bone Joint Surg Br , vol.78 B , pp. 280
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 6
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultrahigh-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH: A novel method of cross-linking ultrahigh-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 16:149, 2001
    • (2001) J Arthroplasty , vol.16 , pp. 149
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 8
    • 0141987355 scopus 로고    scopus 로고
    • Surface analysis of early retrieved Acetabular polyethylenes liners: A comparison of standard and highly cross-linked polyethylenes
    • Dallas, TX
    • Muratoglu OK, et al: Surface analysis of early retrieved Acetabular polyethylenes liners: a comparison of standard and highly cross-linked polyethylenes. ORS Poster 1029, Dallas, TX, 2002
    • (2002) ORS Poster 1029
    • Muratoglu, O.K.1
  • 10
    • 85031064456 scopus 로고    scopus 로고
    • A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty. Alternative bearing surfaces in total joint replacement
    • Jacobs JJ, Craig TL (eds). West Conshohocken, PA: American Society for Testing and Materials
    • Wimmer MA, et al: A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty. Alternative bearing surfaces in total joint replacement. In Jacobs JJ, Craig TL (eds): ASTM STP 1346. West Conshohocken, PA: American Society for Testing and Materials, 1998
    • (1998) ASTM STP 1346
    • Wimmer, M.A.1
  • 12
    • 0034308356 scopus 로고    scopus 로고
    • The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
    • DesJardins JD, Walker PS, Haider H, Perry J: The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. J Biomech 33:1231, 2000
    • (2000) J Biomech , vol.33 , pp. 1231
    • DesJardins, J.D.1    Walker, P.S.2    Haider, H.3    Perry, J.4
  • 13
    • 0017966550 scopus 로고
    • The appearances of wear on polyethylene - A comparison of in vivo and in vitro wear surfaces
    • Rostoker W, Chao EYS, Galante JO: The appearances of wear on polyethylene - a comparison of in vivo and in vitro wear surfaces. J Biomed Mater Res 12:317, 1978
    • (1978) J Biomed Mater Res , vol.12 , pp. 317
    • Rostoker, W.1    Chao, E.Y.S.2    Galante, J.O.3
  • 15
    • 0030625634 scopus 로고    scopus 로고
    • Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements
    • Semlitsch M, Willert HG: Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proc Inst Mech Eng [H] 211:73, 1997
    • (1997) Proc Inst Mech Eng [H] , vol.211 , pp. 73
    • Semlitsch, M.1    Willert, H.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.