메뉴 건너뛰기




Volumn 123, Issue 7, 2003, Pages 353-356

Ten-year follow-up of primary straight-stem prosthesis (MEM) made of titanium or cobalt chromium alloy

Author keywords

Cemented titanium stems; Straight stem prosthesis; Survival ship analysis

Indexed keywords

BONE CEMENT; CHROMIUM DERIVATIVE; COBALT; TITANIUM;

EID: 0141920499     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-003-0555-3     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 0026863992 scopus 로고
    • Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty
    • Cheal EJ, Spector M, Hayes WC (1992) Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty. J Orthop Res 10:405-422
    • (1992) J. Orthop. Res. , vol.10 , pp. 405-422
    • Cheal, E.J.1    Spector, M.2    Hayes, W.C.3
  • 2
    • 0023841425 scopus 로고
    • Role of stem design and material on stress distributions in cemented total hip replacement
    • Christel PS, Meunier A, Blanquaert D, Witvoet J, Sedel L (1988) Role of stem design and material on stress distributions in cemented total hip replacement. J Biomed Eng 10:57-63
    • (1988) J. Biomed. Eng. , vol.10 , pp. 57-63
    • Christel, P.S.1    Meunier, A.2    Blanquaert, D.3    Witvoet, J.4    Sedel, L.5
  • 3
    • 0030972295 scopus 로고    scopus 로고
    • Low loosening rate of a cemented titanium straight shaft prosthesis in long-term follow-up
    • (in German)
    • Eingartner C, Volkmann R, Kummel K, Weller S (1997) Low loosening rate of a cemented titanium straight shaft prosthesis in long-term follow-up (in German). Swiss Surg 3:49-54
    • (1997) Swiss. Surg. , vol.3 , pp. 49-54
    • Eingartner, C.1    Volkmann, R.2    Kummel, K.3    Weller, S.4
  • 4
    • 0034457299 scopus 로고    scopus 로고
    • 10 year results with a cemented fine-grit-blasted titanium-aluminum- vanadium hip endoprosthesis shaft
    • (in German)
    • Hinrichs F, Boudriot U, Griss P (2000) 10 year results with a cemented fine-grit-blasted titanium-aluminum- vanadium hip endoprosthesis shaft (in German). Z Orthop 138:52-56
    • (2000) Z. Orthop. , vol.138 , pp. 52-56
    • Hinrichs, F.1    Boudriot, U.2    Griss, P.3
  • 5
    • 0028787539 scopus 로고
    • Stem loosening more common with ITH than Lubinus prosthesis. A 5-year clinical and radiographic follow-up of 142 patients
    • Jacobsson SA, Ivarsson I, Djerf K, Wahlstrom O (1995) Stem loosening more common with ITH than Lubinus prosthesis. A 5-year clinical and radiographic follow-up of 142 patients. Acta Orthop Scand 66:425-431
    • (1995) Acta Orthop. Scand. , vol.66 , pp. 425-431
    • Jacobsson, S.A.1    Ivarsson, I.2    Djerf, K.3    Wahlstrom, O.4
  • 7
    • 0034998508 scopus 로고    scopus 로고
    • Increased loosening of cemented straight stem prostheses made from titanium alloys. An analysis and comparison with prostheses made of cobalt-chromium-nickel alloy
    • Maurer TB, Ochsner PE, Schwarzer G, Schumacher M (2001) Increased loosening of cemented straight stem prostheses made from titanium alloys. An analysis and comparison with prostheses made of cobalt-chromium-nickel alloy. Int Orthop 25: 77-80
    • (2001) Int. Orthop. , vol.25 , pp. 77-80
    • Maurer, T.B.1    Ochsner, P.E.2    Schwarzer, G.3    Schumacher, M.4
  • 8
    • 0000227225 scopus 로고
    • Clinical and radiographic results of a continuous series of 124 type Ceraver-Osteal hip prostheses with a 9-year survival analysis
    • (in French)
    • Osorovitz P, Goutallier D (1994) Clinical and radiographic results of a continuous series of 124 type Ceraver-Osteal hip prostheses with a 9-year survival analysis (in French). Rev Chir Orthop 80:305-315
    • (1994) Rev. Chir. Orthop. , vol.80 , pp. 305-315
    • Osorovitz, P.1    Goutallier, D.2
  • 9
    • 0034071904 scopus 로고    scopus 로고
    • The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface
    • Ramaniraka NA, Rakotomanana LR, Leyvraz PF (2000) The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface. J Bone Joint Surg Br 82:297-303
    • (2000) J. Bone Joint Surg. Br. , vol.82 , pp. 297-303
    • Ramaniraka, N.A.1    Rakotomanana, L.R.2    Leyvraz, P.F.3
  • 11
    • 0022006750 scopus 로고
    • Radiographic analysis of a low-modulus titanium-alloy femoral total hip component. Two-to six-year follow-up
    • Sarmiento A, Gruen TA (1985) Radiographic analysis of a low-modulus titanium-alloy femoral total hip component. Two-to six-year follow-up. J Bone Joint Surg Am 67:48-56
    • (1985) J. Bone Joint Surg. Am. , vol.67 , pp. 48-56
    • Sarmiento, A.1    Gruen, T.A.2
  • 12
    • 0033856903 scopus 로고    scopus 로고
    • Osteolysis in cemented titanium alloy hip prosthesis
    • Scholl E, Eggli S, Ganz R (2000) Osteolysis in cemented titanium alloy hip prosthesis. J Arthroplasty 15:570-575
    • (2000) J. Arthroplasty , vol.15 , pp. 570-575
    • Scholl, E.1    Eggli, S.2    Ganz, R.3
  • 13
    • 0025778212 scopus 로고
    • Joint prostheses components of warm-forged and surface treated Ti-6Al- 7Nb alloy
    • (in German)
    • Semlitsch M, Weber H, Streicher RM, Schon R (1991) Joint prostheses components of warm-forged and surface treated Ti-6Al- 7Nb alloy (in German). Biomed Tech (Berl) 36:112-119
    • (1991) Biomed. Tech. (Berl) , vol.36 , pp. 112-119
    • Semlitsch, M.1    Weber, H.2    Streicher, R.M.3    Schon, R.4
  • 14
    • 0028567382 scopus 로고
    • A prospective study of a titanium femoral component for cemented total hip arthroplasty
    • Tompkins GS, Lachiewicz PF, DeMasi R (1994) A prospective study of a titanium femoral component for cemented total hip arthroplasty. J Arthroplasty 9:623-630
    • (1994) J. Arthroplasty , vol.9 , pp. 623-630
    • Tompkins, G.S.1    Lachiewicz, P.F.2    DeMasi, R.3
  • 15
    • 0000810696 scopus 로고    scopus 로고
    • Vergleich der Ergebnisse von zementierten Hüftprothesenschäften aus Titan und Kobalt-Chrom-Legierungen
    • Wagner M, Wagner H (1997) Vergleich der Ergebnisse von zementierten Hüftprothesenschäften aus Titan und Kobalt-Chrom-Legierungen. Orthop Praxis 33:589-593
    • (1997) Orthop. Praxis , vol.33 , pp. 589-593
    • Wagner, M.1    Wagner, H.2