메뉴 건너뛰기




Volumn 26, Issue 4, 2003, Pages 269-274

Recurrent hemorrhage after initially complete occlusion of intracranial aneurysms

Author keywords

Clipping; Coil embolization; Intracranial aneurysm; Recurrent hemorrhage

Indexed keywords

ADULT; AGED; ANEURYSM CLIP; ANEURYSM RUPTURE; ANGIOGRAPHY; ARTICLE; BRAIN HEMATOMA; BRAIN HEMORRHAGE; FEMALE; HUMAN; INTRACRANIAL ANEURYSM; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RECURRENT DISEASE; TREATMENT OUTCOME;

EID: 0141892103     PISSN: 03445607     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10143-003-0285-6     Document Type: Article
Times cited : (40)

References (24)
  • 1
    • 0036801579 scopus 로고    scopus 로고
    • Complementary management of partially occluded aneurysms by using surgical or endovascular therapy
    • Asgari S, Doerfler A, Wanke I, Schoch B, Forsting M, Stolke D (2002) Complementary management of partially occluded aneurysms by using surgical or endovascular therapy. J Neurosurg 97:843-850
    • (2002) J Neurosurg , vol.97 , pp. 843-850
    • Asgari, S.1    Doerfler, A.2    Wanke, I.3    Schoch, B.4    Forsting, M.5    Stolke, D.6
  • 2
    • 0032948321 scopus 로고    scopus 로고
    • Treatment of basilar artery bifurcation aneurysms by using Guglielmi detachable coils: A 6-year experience
    • Bavinzski G, Killer M, Gruber A, Reinprecht A, Gross CE, Richling B (1999) Treatment of basilar artery bifurcation aneurysms by using Guglielmi detachable coils: a 6-year experience. J Neurosurg 90:843-852
    • (1999) J Neurosurg , vol.90 , pp. 843-852
    • Bavinzski, G.1    Killer, M.2    Gruber, A.3    Reinprecht, A.4    Gross, C.E.5    Richling, B.6
  • 3
    • 0033062709 scopus 로고    scopus 로고
    • Five-year experience in using coil embolization for ruptured intracranial aneurysms: Outcomes and incidence of late rebleeding
    • Byrne JV, Sohn MJ, Molyneux AJ (1999) Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90:656-663
    • (1999) J Neurosurg , vol.90 , pp. 656-663
    • Byrne, J.V.1    Sohn, M.J.2    Molyneux, A.J.3
  • 5
    • 0021680780 scopus 로고
    • Failed aneurysm surgery. Reoperation in 115 cases
    • Drake CG, Friedman AH, Peerless SJ (1984) Failed aneurysm surgery. Reoperation in 115 cases. J Neurosurg 61:848-856
    • (1984) J Neurosurg , vol.61 , pp. 848-856
    • Drake, C.G.1    Friedman, A.H.2    Peerless, S.J.3
  • 7
    • 0032471547 scopus 로고    scopus 로고
    • Subarachnoid hemorrhage due to late recurrence of a previously unruptured aneurysm after complete endovascular occlusion
    • Hodgson TJ, Carroll T, Jellinek DA (1998) Subarachnoid hemorrhage due to late recurrence of a previously unruptured aneurysm after complete endovascular occlusion. AJNR Am J Neuroradiol 19:1939-1941
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 1939-1941
    • Hodgson, T.J.1    Carroll, T.2    Jellinek, D.A.3
  • 8
    • 0343090363 scopus 로고    scopus 로고
    • Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization
    • Hope JK, Byrne JV, Molyneux AJ (1999) Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization. AJNR Am J Neuroradiol 20:391-399
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 391-399
    • Hope, J.K.1    Byrne, J.V.2    Molyneux, A.J.3
  • 9
    • 0037180253 scopus 로고    scopus 로고
    • International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised trial
    • International Subarachnoid Aneurysm Trial Collaborative Group (2002) International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267-1274
    • (2002) Lancet , vol.360 , pp. 1267-1274
  • 10
    • 0027173880 scopus 로고
    • Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with fatal outcome
    • Klucznik RP, Carrier DA, Pyka R, Haid RW (1993) Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with fatal outcome. Radiology 187:855-856
    • (1993) Radiology , vol.187 , pp. 855-856
    • Klucznik, R.P.1    Carrier, D.A.2    Pyka, R.3    Haid, R.W.4
  • 11
    • 0033801505 scopus 로고    scopus 로고
    • Outcomes of early endovascular versus surgical treatment of ruptured cerebral aneurysms. A prospective randomised study
    • Koivisto T, Vanninen R, Hurskainen H, Saari T, Hemesniemi J, Vapalahti M (2000) Outcomes of early endovascular versus surgical treatment of ruptured cerebral aneurysms. A prospective randomised study. Stroke 31:2369-2377
    • (2000) Stroke , vol.31 , pp. 2369-2377
    • Koivisto, T.1    Vanninen, R.2    Hurskainen, H.3    Saari, T.4    Hemesniemi, J.5    Vapalahti, M.6
  • 14
    • 0033969129 scopus 로고    scopus 로고
    • Early aneurysm recurrence after technically satisfactory Guglielmi detachable coil therapy: Is early surveillance needed? Case report
    • Makoui AS, Smith DA, Evans AJ, Cahill DW (2000) Early aneurysm recurrence after technically satisfactory Guglielmi detachable coil therapy: is early surveillance needed? Case report. J Neurosurg 92:355-358
    • (2000) J Neurosurg , vol.92 , pp. 355-358
    • Makoui, A.S.1    Smith, D.A.2    Evans, A.J.3    Cahill, D.W.4
  • 15
    • 0031841365 scopus 로고    scopus 로고
    • Rerupture of coil-embolized aneurysm during long-term observation. Case report
    • Manabe H, Fujita S, Hatayama T, Suzuki S, Yagihashi S (1998) Rerupture of coil-embolized aneurysm during long-term observation. Case report. J Neurosurg 88:1096-1098
    • (1998) J Neurosurg , vol.88 , pp. 1096-1098
    • Manabe, H.1    Fujita, S.2    Hatayama, T.3    Suzuki, S.4    Yagihashi, S.5
  • 17
    • 0029069722 scopus 로고
    • Histological findings in giant aneurysms treated with Guglielmi detachable coils. Report of two cases with autopsy correlation
    • Molyneux AJ, Ellison DW, Morris J, Byrne JV (1995) Histological findings in giant aneurysms treated with Guglielmi detachable coils. Report of two cases with autopsy correlation. J Neurosurg 83:129-132
    • (1995) J Neurosurg , vol.83 , pp. 129-132
    • Molyneux, A.J.1    Ellison, D.W.2    Morris, J.3    Byrne, J.V.4
  • 18
    • 0033866233 scopus 로고    scopus 로고
    • Prospective analysis of aneurysm treatment in a series of 103 consecutive patients when endovascular embolization is considered the first opinion
    • Raftopoulos C, Mathurin P, Boscherini D, Billa RF, Van Boven M, Hantson P (2000) Prospective analysis of aneurysm treatment in a series of 103 consecutive patients when endovascular embolization is considered the first opinion. J Neurosurg 93:175-182
    • (2000) J Neurosurg , vol.93 , pp. 175-182
    • Raftopoulos, C.1    Mathurin, P.2    Boscherini, D.3    Billa, R.F.4    Van Boven, M.5    Hantson, P.6
  • 19
    • 0031973836 scopus 로고    scopus 로고
    • Angiography after aneurysm surgery: Indications for selective angiography
    • Rauzzino MJ, Quinn CM, Fisher WS III (1998) Angiography after aneurysm surgery: indications for selective angiography. Surg Neurol 49:32-41
    • (1998) Surg Neurol , vol.49 , pp. 32-41
    • Rauzzino, M.J.1    Quinn, C.M.2    Fisher W.S. III3
  • 20
    • 0036891641 scopus 로고    scopus 로고
    • Biomedical implants and devices: Assessment of magnetic field interactions with a 3.0 Tesla MR system
    • Shellock FG (2002) Biomedical implants and devices: assessment of magnetic field interactions with a 3.0 Tesla MR system. J Magn Reson Imaging 16:721-732
    • (2002) J Magn Reson Imaging , vol.16 , pp. 721-732
    • Shellock, F.G.1
  • 21
    • 0031757292 scopus 로고    scopus 로고
    • Aneurysmal remnants after microsurgical clipping: Classification and results from a prospective angiographic study (in a consecutive series of 305 operated intracranial aneurysms)
    • Sindou M, Acevedo JC, Turjman F (1998) Aneurysmal remnants after microsurgical clipping: classification and results from a prospective angiographic study (in a consecutive series of 305 operated intracranial aneurysms). Acta Neurochir (Wien) 140:1153-1159
    • (1998) Acta Neurochir (Wien) , vol.140 , pp. 1153-1159
    • Sindou, M.1    Acevedo, J.C.2    Turjman, F.3
  • 22
    • 0032928663 scopus 로고    scopus 로고
    • Interdisciplinary management results in 100 patients with ruptured and unruptured posterior circulation aneurysms
    • Steiger HJ, Medele R, Brückmann H, Schroth G, Reulen HJ (1999) Interdisciplinary management results in 100 patients with ruptured and unruptured posterior circulation aneurysms. Acta Neurochir (Wien) 141:359-367
    • (1999) Acta Neurochir (Wien) , vol.141 , pp. 359-367
    • Steiger, H.J.1    Medele, R.2    Brückmann, H.3    Schroth, G.4    Reulen, H.J.5
  • 23
    • 0017197627 scopus 로고
    • Comparative study of the pressure of various aneurysm clips
    • Sugita K, Hirota T, Iguchi I, Mizutani T (1976) Comparative study of the pressure of various aneurysm clips. J Neurosurg 44:723-727
    • (1976) J Neurosurg , vol.44 , pp. 723-727
    • Sugita, K.1    Hirota, T.2    Iguchi, I.3    Mizutani, T.4
  • 24
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acute intracranial aneurysm: Perioperative anatomical and clinical outcome in 403 patients
    • Vinuela F, Duckwiler G, Mawad M (1997) Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86:475-482
    • (1997) J Neurosurg , vol.86 , pp. 475-482
    • Vinuela, F.1    Duckwiler, G.2    Mawad, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.