1
-
-
0037815710
-
Particular requirements for the safety of magnetic resonance equipment for medical diagnosis
-
International electrotechnical commission (IEC), 3 rue de Varembe. P.O.-Box 131, CH-1211 Geneva 20, Switzerland
-
IEC. Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. In: Diagnostic imaging equipment. Publication of the IEC 60601-2-33, medical electrical equipment, part 2. International electrotechnical commission (IEC), 3 rue de Varembe. P.O.-Box 131, CH-1211 Geneva 20, Switzerland, 1995.
-
(1995)
Diagnostic Imaging Equipment. Publication of the IEC 60601-2-33, Medical Electrical Equipment, Part 2
-
-
-
4
-
-
0030879510
-
Peripheral nerve stimulation by time-varying magnetic fields
-
Abart J, Eberhardt K, Fischer H, Huk W, Richter E, Schmitt F, Storch T, Zeitler E. Peripheral nerve stimulation by time-varying magnetic fields. J Comput Assis Tomogr 1997;21:532-8.
-
(1997)
J Comput Assis Tomogr
, vol.21
, pp. 532-538
-
-
Abart, J.1
Eberhardt, K.2
Fischer, H.3
Huk, W.4
Richter, E.5
Schmitt, F.6
Storch, T.7
Zeitler, E.8
-
6
-
-
0031397354
-
Peripheral nerve stimulation in a whole-body echo-planar imaging system
-
Ehrhardt JC, Lin CS, Magnotta VA, Fisher DJ, Yuh WTC. Peripheral nerve stimulation in a whole-body echo-planar imaging system. J Magn Reson Imag 1997;7:405-9.
-
(1997)
J Magn Reson Imag
, vol.7
, pp. 405-409
-
-
Ehrhardt, J.C.1
Lin, C.S.2
Magnotta, V.A.3
Fisher, D.J.4
Yuh, W.T.C.5
-
7
-
-
0031401005
-
Peripheral nerve stimulation during MRI: Effects of high gradient amplitudes and switching rates
-
Ham CLG, Engels JML, van de Wiel GT, Machielsen A. Peripheral nerve stimulation during MRI: effects of high gradient amplitudes and switching rates. J Magn Reson Imag 1997;7:933-7.
-
(1997)
J Magn Reson Imag
, vol.7
, pp. 933-937
-
-
Ham, C.L.G.1
Engels, J.M.L.2
Van de Wiel, G.T.3
Machielsen, A.4
-
8
-
-
0003144590
-
Determination of gradient-induced, human peripheral nerve stimulation threshold for trapezoidal pulse trains
-
San Francisco, USA
-
Schafer DJ, Bourland JD, Nyenhuis JA, Foster KS, Wirth WF, Geddes LA, Riehl ME. Determination of gradient-induced, human peripheral nerve stimulation threshold for trapezoidal pulse trains. In: Proceedings of the Society of Magnetic Resonance 2nd Annual Meeting, San Francisco, USA: 1994:101.
-
(1994)
Proceedings of the Society of Magnetic Resonance 2nd Annual Meeting
, pp. 101
-
-
Schafer, D.J.1
Bourland, J.D.2
Nyenhuis, J.A.3
Foster, K.S.4
Wirth, W.F.5
Geddes, L.A.6
Riehl, M.E.7
-
9
-
-
0005487412
-
Effects of simultaneous combinations on human peripheral nerve stimulation thresholds
-
Nizza, France
-
Schaefer DJ, Bourland JD, Nyenhuis JA, Foster KS, Licato PE, Geddes LA. Effects of simultaneous combinations on human peripheral nerve stimulation thresholds. In: Proceedings of the Society of Magnetic Resonance 3rd Annual Meeting, Nizza, France: 1995:1220.
-
(1995)
Proceedings of the Society of Magnetic Resonance 3rd Annual Meeting
, pp. 1220
-
-
Schaefer, D.J.1
Bourland, J.D.2
Nyenhuis, J.A.3
Foster, K.S.4
Licato, P.E.5
Geddes, L.A.6
-
11
-
-
0034070036
-
Electromyography in MRI: First recordings of peripheral nerve activation caused by fast magnetic field gradients
-
Hoffmann A, Faber SC, Werhahn KJ, Jager L, Reiser M. Electromyography in MRI: First recordings of peripheral nerve activation caused by fast magnetic field gradients. Magn Reson Med 2000;43:534-9.
-
(2000)
Magn Reson Med
, vol.43
, pp. 534-539
-
-
Hoffmann, A.1
Faber, S.C.2
Werhahn, K.J.3
Jager, L.4
Reiser, M.5
-
12
-
-
0025443676
-
A model of the stimulation of a nerve fiber by electromagnetic induction
-
Roth BJ, Basser PJ. A model of the stimulation of a nerve fiber by electromagnetic induction. IEEE Trans Biomed Eng 1990;37:588-97.
-
(1990)
IEEE Trans Biomed Eng
, vol.37
, pp. 588-597
-
-
Roth, B.J.1
Basser, P.J.2
|