BRAIN;
ELECTRODES;
HYPERTHERMIA THERAPY;
MAGNETIC RESONANCE IMAGING;
PATIENT TREATMENT;
TISSUE;
NEUROSTIMULATORS;
IMPLANTS (SURGICAL);
ARTICLE;
BONE PLATE;
BONE PROSTHESIS;
BONE SCREW;
BRAIN DEPTH STIMULATION;
BRAIN INJURY;
BRAIN TISSUE;
CLINICAL EXAMINATION;
CONTROLLED STUDY;
DETERIORATION;
DEVICE;
DIATHERMY;
DISEASE SEVERITY;
ELECTRODE;
FIBER OPTICS;
HEATING;
IN VITRO STUDY;
KYPHOSIS;
LABORATORY TEST;
MEDICAL LITERATURE;
MENTAL HEALTH;
METAL IMPLANTATION;
NERVE STIMULATION;
NEUROLOGIC DISEASE;
NUCLEAR MAGNETIC RESONANCE IMAGING;
PACEMAKER ELECTRODE;
PARKINSON DISEASE;
PRIORITY JOURNAL;
RADIATION ABSORPTION;
RADIATION EXPOSURE;
RADIOFREQUENCY RADIATION;
SPINAL CORD STIMULATION;
TEMPERATURE MEASUREMENT;
THERMOMETRY;
TOOTH EXTRACTION;
BODY TEMPERATURE;
DIATHERMY;
ELECTRIC WIRING;
ENERGY TRANSFER;
HEAT;
HUMANS;
METALS;
PACEMAKER, ARTIFICIAL;
PROSTHESES AND IMPLANTS;
RADIATION DOSAGE;
RADIATION PROTECTION;
RADIO WAVES;
RADIOMETRY;
RELATIVE BIOLOGICAL EFFECTIVENESS;
Cyberonic Safety Alert, Dear Doctor, Medical Staff, or Hospital Administrators 27 August
Cyberonic Safety Alert, Dear Doctor, Medical Staff, or Hospital Administrators 27 August 2001 http://www.cyberonics.com/physician/diathermy-clinicians-us.htm
(2001)
4
0035956558
Letter to editor: DBS and diathermy interaction induces severe CNS damage
Dommerholt J and Issa T 2001 Letter to editor: DBS and diathermy interaction induces severe CNS damage Neurology 57 2324-5
FDA MAUDE Database FOITEXT2001A.ZIP, Report Number 313131 (10 January 2001)
FDA MAUDE Database 2001a FOITEXT2001A.ZIP, Report Number 313131 (10 January 2001) http://www.fda.gov/cdrh/maude.html
(2001)
6
0141464891
FDA MAUDE Database FOITEXT2001A.ZIP, Report Number 330144 (30 March 2001)
FDA MAUDE Database 2001b FOITEXT2001A.ZIP, Report Number 330144 (30 March 2001) http://www.fda.gov/cdrh/maude.html
(2001)
7
0141464889
FDA Public Health Notification Food and Drug Administration, Center for Devices and Radiological Health (19 December 2002)
FDA Public Health Notification 2002 Diathermy Interactions with Implanted Leads and Implanted Systems with Leads Food and Drug Administration, Center for Devices and Radiological Health (19 December 2002)
IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz
Institute of Electrical and Electronic Engineering, Inc. 27 April IEEE C95.1-1991
IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz, IEEE C95.1-1991, Institute of Electrical and Electronic Engineering, Inc. 27 April 1992
(1992)
11
0141464890
MDA Safety Notice, Patients with Active/Powered Implants: Risk of Serious Injury from Therapeutic Diathermy Treatment
August MDA SN2001 (23), 23/07/20010614.010-9
MDA Safety Notice, Patients with Active/Powered Implants: Risk of Serious Injury from Therapeutic Diathermy Treatment, MDA SN2001 (23), 23/07/20010614.010-9, August 2001
(2001)
12
0141464892
Medtronic Safety Alert, Dear Doctor and Medical Staff, May 16, www.medtronic.com/neuro/diathermy-alert/alert-physicians
Medtronic Safety Alert, Dear Doctor and Medical Staff, May 16, 2001 www.medtronic.com/neuro/diathermy-alert/alert-physicians
(2001)
13
0141576532
Reply to Dommerholt and Issa letter to editor
Nutt J D 2001 Reply to Dommerholt and Issa letter to editor Neurology 57 2325
Heating near implanted medical devices by the MRI RF-magnetic field
Nyenhuis J A, Kildishev A V, Bourland J D, Foster K S, Graber G P and Athey T W 1999 Heating near implanted medical devices by the MRI RF-magnetic field IEEE Trans. Magn. 35 4133-5