메뉴 건너뛰기




Volumn 59, Issue 1, 2003, Pages 12-16

Opto-electronic plethysmograpy

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; AIRFLOW; AIRWAY PRESSURE; ASTHMA; BIOMEDICAL TECHNOLOGY ASSESSMENT; BODY POSTURE; BREATHING PATTERN; BRONCHOSPASM; CALIBRATION; CHRONIC OBSTRUCTIVE LUNG DISEASE; DEVICE; DIAGNOSTIC VALUE; ENERGY TRANSFER; EXERCISE; HUMAN; INTENSIVE CARE; LUNG BLOOD FLOW; LUNG FUNCTION TEST; LUNG VENTILATION; LUNG VOLUME; NON INVASIVE MEASUREMENT; OPTOELECTRONIC PLETHYSMOGRAPHY; PERIPHERAL CIRCULATION; PLETHYSMOGRAPHY; POSITIVE END EXPIRATORY PRESSURE; RESPIRATORY TRACT PARAMETERS; REVIEW; STANDING; SUPINE POSITION; THORAX WALL; ARTICLE; BLOOD VOLUME; METHODOLOGY; PHYSIOLOGY;

EID: 0141794260     PISSN: 11220643     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (65)

References (26)
  • 1
    • 0015384501 scopus 로고
    • Changes in tidal volume, frequency, and ventilation induced by their measurement
    • Gilbert R, Auchincloss JH Jr, Brodsky J, Boden W. Changes in tidal volume, frequency, and ventilation induced by their measurement. J Appl Physiol 33 (2): 252-4, 1972.
    • (1972) J Appl Physiol , vol.33 , Issue.2 , pp. 252-254
    • Gilbert, R.1    Auchincloss J.H., Jr.2    Brodsky, J.3    Boden, W.4
  • 3
    • 0014060388 scopus 로고
    • Measurement of the separate volume changes of rib cage and abdomen during breathing
    • Konno K, Mead J. Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol 22: 407-422, 1967.
    • (1967) J Appl Physiol , vol.22 , pp. 407-422
    • Konno, K.1    Mead, J.2
  • 4
    • 77049180654 scopus 로고
    • Movements of the thoracic cage and diaphragm in respiration
    • Wade OL. Movements of the thoracic cage and diaphragm in respiration. J Physiol (Lond) 124: 193, 1954.
    • (1954) J Physiol (Lond) , vol.124 , pp. 193
    • Wade, O.L.1
  • 5
    • 0014196848 scopus 로고
    • Pulmonary ventilation measured from body surface movements
    • Mead J, Peterson N, Grimby G, Mead J. Pulmonary ventilation measured from body surface movements. Science 156: 1383-1384, 1967.
    • (1967) Science , vol.156 , pp. 1383-1384
    • Mead, J.1    Peterson, N.2    Grimby, G.3    Mead, J.4
  • 7
    • 0017486586 scopus 로고
    • Inductive plethysmography - A new respiratory transducer
    • Milledge JS, Stott FD Inductive plethysmography - A new respiratory transducer. J Physiol (Lond) 267: 4, 1977.
    • (1977) J Physiol (Lond) , vol.267 , pp. 4
    • Milledge, J.S.1    Stott, F.D.2
  • 8
    • 0019963688 scopus 로고
    • Validation of respiratory inductive plethysmography using different calibration procedures
    • Chadha TS, Watson H, Birch S, et al. Validation of respiratory inductive plethysmography using different calibration procedures. Am Rev Respir Dis 125: 644, 1982.
    • (1982) Am Rev Respir Dis , vol.125 , pp. 644
    • Chadha, T.S.1    Watson, H.2    Birch, S.3
  • 10
    • 0020685191 scopus 로고
    • Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory-inductive plethysmograph
    • Zimmerman PV, Connellan SJ, Middleton HC, Tabona MV, Goldman MD, Price N. Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory-inductive plethysmograph. Am Rev Respir Dis 127: 209-214, 1983.
    • (1983) Am Rev Respir Dis , vol.127 , pp. 209-214
    • Zimmerman, P.V.1    Connellan, S.J.2    Middleton, H.C.3    Tabona, M.V.4    Goldman, M.D.5    Price, N.6
  • 11
    • 0022270338 scopus 로고
    • ELITE: A digital dedicated hardware system for movement analysis via real-time TV signal processing
    • Ferrigno G, Pedotti A. ELITE: A digital dedicated hardware system for movement analysis via real-time TV signal processing. IEEE Trans Biomed Eng 32: 943-950, 1985.
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 943-950
    • Ferrigno, G.1    Pedotti, A.2
  • 14
    • 0010404572 scopus 로고
    • Statics of the chest wall
    • edited by C. Roussos and P.T. Macklem. New York: Dekker; (Lung Biol Health Dis Ser)
    • Agostino E, D'Angelo E. Statics of the chest wall. In: The Thorax, edited by C. Roussos and P.T. Macklem. New York: Dekker, 1988, p. 259-295 (Lung Biol Health Dis Ser).
    • (1988) The Thorax , pp. 259-295
    • Agostino, E.1    D'Angelo, E.2
  • 15
    • 0034745190 scopus 로고    scopus 로고
    • Compartmental analysis of breathing in the supine and prone positions by Opto-Electronic Plethysmography
    • Aliverti A, Dellacà R, Pelosi P, Chiumello D, Gattinoni L, Pedotti A. Compartmental analysis of breathing in the supine and prone positions by Opto-Electronic Plethysmography. Ann Biomed Eng 29: 60-70, 2001.
    • (2001) Ann Biomed Eng , vol.29 , pp. 60-70
    • Aliverti, A.1    Dellacà, R.2    Pelosi, P.3    Chiumello, D.4    Gattinoni, L.5    Pedotti, A.6
  • 20
    • 0038305520 scopus 로고
    • The pressure-volume diagram of the thorax and lung
    • Rahn H, Otis AB, Chadwick LE, Fenn WO. The pressure-volume diagram of the thorax and lung. Am J Physiol 146: 161-178, 1946.
    • (1946) Am J Physiol , vol.146 , pp. 161-178
    • Rahn, H.1    Otis, A.B.2    Chadwick, L.E.3    Fenn, W.O.4
  • 22
    • 0034745191 scopus 로고    scopus 로고
    • Transfer impedance of the respiratory system by forced oscillation technique by optoelectronic plethysmography
    • Aliverti A, Dellacà R, Pedotti A. Transfer impedance of the respiratory system by forced oscillation technique by optoelectronic plethysmography. Ann Biomed Eng 29: 71-82, 2001.
    • (2001) Ann Biomed Eng , vol.29 , pp. 71-82
    • Aliverti, A.1    Dellacà, R.2    Pedotti, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.