메뉴 건너뛰기




Volumn 175, Issue 9, 2003, Pages 1251-1258

B-flow and color-coded B-flow in sonographic diagnosis of filiform stenosis of the internal carotid artery;B-flow und color-coded-B-flow zur sonographischen diagnostik der filiformen stenose der A. carotis interna

Author keywords

B flow; DSA; Filiform ICA stenosis; MRA; Power Doppler

Indexed keywords

CONTRAST MEDIUM; FS 069;

EID: 0141783640     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-41936     Document Type: Article
Times cited : (9)

References (37)
  • 1
    • 0025734372 scopus 로고
    • Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade stenosis
    • North American Symptomatic Carotid Endarterectomy Trial Collaborators. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade stenosis. N Engl J Med 1991; 325: 445-452
    • (1991) N Engl J Med , vol.325 , pp. 445-452
  • 2
    • 0008451765 scopus 로고
    • Risk of stroke in the distribution of an asymptomatic carotid artery
    • European Carotid Surgery Trialists Collaborative Group. Risk of stroke in the distribution of an asymptomatic carotid artery. Lancet 1995; 345: 445-453
    • (1995) Lancet , vol.345 , pp. 445-453
  • 3
    • 0142142905 scopus 로고    scopus 로고
    • B-Flow und kontrastmittelverstärkter power mode mit optison® - Präoperative diagnostik der hochgradigen stenose der A. carotis interna
    • Jung EM, Kubale R, Clevert D-A, Lutz R, Rupp N. B-Flow und kontrastmittelverstärkter Power Mode mit Optison® - Präoperative Diagnostik der hochgradigen Stenose der A. carotis interna. Fortschr Röntgenstr 2002; 174: 62-69
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 62-69
    • Jung, E.M.1    Kubale, R.2    Clevert, D.-A.3    Lutz, R.4    Rupp, N.5
  • 4
    • 0034894962 scopus 로고    scopus 로고
    • Carotid ultrasound
    • Polak JF. Carotid ultrasound. Radiol Clin N Amer 2001; 39: 569-589
    • (2001) Radiol Clin N Amer , vol.39 , pp. 569-589
    • Polak, J.F.1
  • 5
    • 0034556236 scopus 로고    scopus 로고
    • Variability in Doppler ultrasound influences referral of patients for carotid surgery
    • Mead GE, Lewis SC, Wardlaw JM. Variability in Doppler ultrasound influences referral of patients for carotid surgery. Eur J Ultrasound 2000: 12: 137-143
    • (2000) Eur J Ultrasound , vol.12 , pp. 137-143
    • Mead, G.E.1    Lewis, S.C.2    Wardlaw, J.M.3
  • 8
    • 0033936514 scopus 로고    scopus 로고
    • Three-dimensional ultrasound observation of carotid artery plaque ulceration
    • Schminke U, Motsch L, Hilker I, Kessler C. Three-dimensional ultrasound observation of carotid artery plaque ulceration. Stroke 2000; 31: 1651-1655
    • (2000) Stroke , vol.31 , pp. 1651-1655
    • Schminke, U.1    Motsch, L.2    Hilker, I.3    Kessler, C.4
  • 9
    • 0031666756 scopus 로고    scopus 로고
    • Hypoechoic plaque at US of the carotid artery: An independent risk factor for incedent stroke in adults aged 65 years or older. Cardiovascular Health Study
    • Polak JF, Shemnski I, O'Leary DH, Lefkowitz D, Price TR, Savage PJ, Brant WE, Reid C. Hypoechoic plaque at US of the carotid artery: an independent risk factor for incedent stroke in adults aged 65 years or older. Cardiovascular Health Study. Radiology 1998; 209: 288-289
    • (1998) Radiology , vol.209 , pp. 288-289
    • Polak, J.F.1    Shemnski, I.2    O'Leary, D.H.3    Lefkowitz, D.4    Price, T.R.5    Savage, P.J.6    Brant, W.E.7    Reid, C.8
  • 11
    • 0034465851 scopus 로고    scopus 로고
    • Prediction of angiographic carotid artery stenosis indexes by colour Doppler-assisted duplex imaging. A critical appraisal of the parameters used
    • Bonig L, Weder B, Schott D, Keel A, Nguyen T, Zaunbauer W. Prediction of angiographic carotid artery stenosis indexes by colour Doppler-assisted duplex imaging. A critical appraisal of the parameters used. Eur J Neurol 2000; 7: 183-190
    • (2000) Eur J Neurol , vol.7 , pp. 183-190
    • Bonig, L.1    Weder, B.2    Schott, D.3    Keel, A.4    Nguyen, T.5    Zaunbauer, W.6
  • 12
    • 0033968316 scopus 로고    scopus 로고
    • Variability of Doppler US measurements along the common carotid artery: Effects on estimates of internal carotid arterial stenosis in patients with angiographically proved disease
    • Lee VS, Hertzberg BS, Workman MJ, Smith TP, Kliewer MA, DeLong DM, Carroll BA. Variability of Doppler US measurements along the common carotid artery: effects on estimates of internal carotid arterial stenosis in patients with angiographically proved disease. Radiology 2000; 214: 387-392
    • (2000) Radiology , vol.214 , pp. 387-392
    • Lee, V.S.1    Hertzberg, B.S.2    Workman, M.J.3    Smith, T.P.4    Kliewer, M.A.5    DeLong, D.M.6    Carroll, B.A.7
  • 13
    • 0036174478 scopus 로고    scopus 로고
    • Contrast-enhanced 3D MR Angiography of carotid artery: Comparison with conventional digital subtraction angiography
    • Remonda L, Senn P, Barth A, Arnold M, Lövblad K-O, Schroth G. Contrast-enhanced 3D MR Angiography of carotid artery: comparison with conventional digital subtraction angiography. Am J Neuroradiol 2002: 13: 213-219
    • (2002) Am J Neuroradiol , vol.13 , pp. 213-219
    • Remonda, L.1    Senn, P.2    Barth, A.3    Arnold, M.4    Lövblad, K.-O.5    Schroth, G.6
  • 14
    • 0034756429 scopus 로고    scopus 로고
    • Carotid atherosclerotic plaque: Noninvasive MR characterization and identification of vulnerable lesions
    • Yuan C, Mitsumori LM, Beach KW, Maravilla KR. Carotid atherosclerotic plaque: noninvasive MR characterization and identification of vulnerable lesions. Radiology 2001; 221: 285-299
    • (2001) Radiology , vol.221 , pp. 285-299
    • Yuan, C.1    Mitsumori, L.M.2    Beach, K.W.3    Maravilla, K.R.4
  • 17
    • 0034969330 scopus 로고    scopus 로고
    • Carotid artery stenosis: Prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography
    • Randoux B, Marro B, Koskas F, Duyme M, Sahel M, Zouaoui A, Marsault C. Carotid artery stenosis: prospective comparison of CT, three-dimensional gadolinium-enhanced MR, and conventional angiography. Radiology 2001; 220: 179-185
    • (2001) Radiology , vol.220 , pp. 179-185
    • Randoux, B.1    Marro, B.2    Koskas, F.3    Duyme, M.4    Sahel, M.5    Zouaoui, A.6    Marsault, C.7
  • 18
    • 0035036527 scopus 로고    scopus 로고
    • Perivaskuläre gewebsvibrationen: Ein kriterium hochgradiger stenosen der A. carotis interna
    • Arning C. Perivaskuläre Gewebsvibrationen: ein Kriterium hochgradiger Stenosen der A. carotis interna. Ultraschall in Med 2001; 22: 62-65
    • (2001) Ultraschall in Med , vol.22 , pp. 62-65
    • Arning, C.1
  • 19
    • 0034968099 scopus 로고    scopus 로고
    • Nonstenotic internal carotid arteries: Effects of age and blood pressure at the time of scanning on Doppler US velocity measurements
    • Spencer E, Sheafor D, Hertzberg B, Bowie JD, Nelson R, Caroll B, Kliewer M. Nonstenotic internal carotid arteries: Effects of age and blood pressure at the time of scanning on Doppler US velocity measurements. Radiology 2001; 220: 174-178
    • (2001) Radiology , vol.220 , pp. 174-178
    • Spencer, E.1    Sheafor, D.2    Hertzberg, B.3    Bowie, J.D.4    Nelson, R.5    Caroll, B.6    Kliewer, M.7
  • 21
    • 0032928089 scopus 로고    scopus 로고
    • Accuracy of the main Doppler methods for evaluating the degree of carotid stenoses (continuous wave, pulsed wave and color Doppler)
    • Arbeille P, Bouin-Pineau MH, Herault S. Accuracy of the main Doppler methods for evaluating the degree of carotid stenoses (continuous wave, pulsed wave and color Doppler). Ultrasound Med Biol 1999; 25: 65-73
    • (1999) Ultrasound Med Biol , vol.25 , pp. 65-73
    • Arbeille, P.1    Bouin-Pineau, M.H.2    Herault, S.3
  • 22
    • 0035133164 scopus 로고    scopus 로고
    • Power Doppler US. evaluation of the morphology of stenoses with a flow phantom
    • Claudon M, Winninger D, Briancon S, Pesque P. Power Doppler US: evaluation of the morphology of stenoses with a flow phantom. Radiology 2001; 218: 109-117
    • (2001) Radiology , vol.218 , pp. 109-117
    • Claudon, M.1    Winninger, D.2    Briancon, S.3    Pesque, P.4
  • 23
    • 0035650696 scopus 로고    scopus 로고
    • Comparison of color-flow Doppler scanning, power Doppler scanning, and frequency shift for assessment of carotid artery stenosis
    • Müller M, Ciccotti R, Reiche W, Hagen T. Comparison of color-flow Doppler scanning, power Doppler scanning, and frequency shift for assessment of carotid artery stenosis. J Vasc Surg 2001; 34: 1090-1095
    • (2001) J Vasc Surg , vol.34 , pp. 1090-1095
    • Müller, M.1    Ciccotti, R.2    Reiche, W.3    Hagen, T.4
  • 24
  • 25
    • 0033855256 scopus 로고    scopus 로고
    • Diagnostik der präokklusiven stenose der A. carotis interna durch ultraschall im power mode
    • Jung EM, Butter F, Rupp N. Diagnostik der präokklusiven Stenose der A. carotis interna durch Ultraschall im Power Mode. Fortschr Röntgenstr 2000; 172: 636-640
    • (2000) Fortschr Röntgenstr , vol.172 , pp. 636-640
    • Jung, E.M.1    Butter, F.2    Rupp, N.3
  • 27
    • 0034105199 scopus 로고    scopus 로고
    • B-Flow - Eine neue methode zur blutflussdetektion
    • Weskott H-P. B-Flow - eine neue Methode zur Blutflussdetektion. Ultraschall in Med 2000; 21: 59-65
    • (2000) Ultraschall in Med , vol.21 , pp. 59-65
    • Weskott, H.-P.1
  • 28
    • 0031909447 scopus 로고    scopus 로고
    • High-grade stenosis of the internal carotid artery assessed by color and power Doppler imaging
    • Schmidt P, Sliwka U, Simon SG, Noth J. High-grade stenosis of the internal carotid artery assessed by color and power Doppler imaging. J Clin Ultrasound 1998; 26: 85-89
    • (1998) J Clin Ultrasound , vol.26 , pp. 85-89
    • Schmidt, P.1    Sliwka, U.2    Simon, S.G.3    Noth, J.4
  • 29
    • 0031012027 scopus 로고    scopus 로고
    • Amplitude Doppler US: Slow blood flow detection level tested with a flow phantom
    • Weskott H-P. Amplitude Doppler US: Slow blood flow detection level tested with a flow phantom. Radiology 1998; 202: 125-130
    • (1998) Radiology , vol.202 , pp. 125-130
    • Weskott, H.-P.1
  • 30
    • 0030720336 scopus 로고    scopus 로고
    • Power Doppler imaging of carotid artery stenosis. Comparison with color Doppler flow imaging and angiography
    • Steinke W, Ries S, Artemis N, Schwartz A, Hennerici M. Power Doppler imaging of carotid artery stenosis. Comparison with color Doppler flow imaging and angiography. Stroke 1997; 28: 1981-1987
    • (1997) Stroke , vol.28 , pp. 1981-1987
    • Steinke, W.1    Ries, S.2    Artemis, N.3    Schwartz, A.4    Hennerici, M.5
  • 31
    • 0034834599 scopus 로고    scopus 로고
    • B-Flow - Sonographische beurteilung und therapie femoraler pseudoaneurysmen
    • Jung EM, Lutz R, Clevert D-A, Rupp N. B-Flow - sonographische Beurteilung und Therapie femoraler Pseudoaneurysmen. Fortschr Röntgenstr 2001; 173: 805-809
    • (2001) Fortschr Röntgenstr , vol.173 , pp. 805-809
    • Jung, E.M.1    Lutz, R.2    Clevert, D.-A.3    Rupp, N.4
  • 32
    • 0345466561 scopus 로고    scopus 로고
    • Echocontrast-enhanced ultrasound of extracranial internal carotid artery high-grade stenosis and occlusion
    • Droste DW, Jürgens R, Nabavi DG, Schuierer G, Weber S, Ringelstein E. Echocontrast-enhanced ultrasound of extracranial internal carotid artery high-grade stenosis and occlusion. Stroke 1999; 30: 2302-2306
    • (1999) Stroke , vol.30 , pp. 2302-2306
    • Droste, D.W.1    Jürgens, R.2    Nabavi, D.G.3    Schuierer, G.4    Weber, S.5    Ringelstein, E.6
  • 34
    • 0031826195 scopus 로고    scopus 로고
    • Safety of human albumin as constituent of biologic therapeutic products
    • Mc Cleland DBL. Safety of human albumin as constituent of biologic therapeutic products. Transfusion 1998; 38: 690-699
    • (1998) Transfusion , vol.38 , pp. 690-699
    • Mc Cleland, D.B.L.1
  • 35
    • 0030907221 scopus 로고    scopus 로고
    • Characteristics and clinical value of intravenous echo-enhancement agent in evaluation of high-grade internal carotid stenosis
    • Sitzer M, Rose G, Fürst G, Siebler M, Steinmetz H. Characteristics and clinical value of intravenous echo-enhancement agent in evaluation of high-grade internal carotid stenosis. J Neuroimaging 1997; 7 (suppl): 22-25
    • (1997) J Neuroimaging , vol.7 , Issue.SUPPL. , pp. 22-25
    • Sitzer, M.1    Rose, G.2    Fürst, G.3    Siebler, M.4    Steinmetz, H.5
  • 36
    • 0033104159 scopus 로고    scopus 로고
    • Lumen reduction measurements of internal carotid artery before and after Levovist enhancement: Reproducibility and agreement with angiography
    • Elgersma OE, Leeuwen MS van, Meijer R, Eikelboom BC, Graf Y van der. Lumen reduction measurements of internal carotid artery before and after Levovist enhancement: reproducibility and agreement with angiography. J Ultrasound Med 1999; 18: 191-201
    • (1999) J Ultrasound Med , vol.18 , pp. 191-201
    • Elgersma, O.E.1    Van Leeuwen, M.S.2    Meijer, R.3    Eikelboom, B.C.4    Van der Graf, Y.5
  • 37
    • 0033936514 scopus 로고    scopus 로고
    • Three-dimensional ultrasound observation of carotid artery plaque ulceration
    • Schminke U, Motsch L, Hilker L, Kessler C. Three-dimensional ultrasound observation of carotid artery plaque ulceration. Stroke 2000; 31: 1651-1655
    • (2000) Stroke , vol.31 , pp. 1651-1655
    • Schminke, U.1    Motsch, L.2    Hilker, L.3    Kessler, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.