메뉴 건너뛰기




Volumn 44, Issue 8, 2003, Pages 1219-1224

Mediastinal lymph node involvement in non-small cell lung cancer: Evaluation with 99mTc-tetrofosmin SPECT and comparison with CT

Author keywords

99mTc tetrofosmin; CT; Mediastinal lymph nodes; Non small cell lung cancer; SPECT

Indexed keywords

TETROFOSMIN TC 99M; DIAGNOSTIC AGENT; ORGANOPHOSPHORUS COMPOUND; RADIOPHARMACEUTICAL AGENT; TECHNETIUM COMPLEX; TECHNETIUM TC 99M 1,2 BIS(BIS(2 ETHOXYETHYL)PHOSPHINO)ETHANE; TECHNETIUM TC 99M 1,2-BIS(BIS(2-ETHOXYETHYL)PHOSPHINO)ETHANE;

EID: 0141781305     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (19)

References (30)
  • 2
    • 0034935029 scopus 로고    scopus 로고
    • Mediastinal staging of non-small-cell lung cancer
    • Lloyd C, Silvestri GA. Mediastinal staging of non-small-cell lung cancer. Cancer Control. 2001;8:311-317.
    • (2001) Cancer Control , vol.8 , pp. 311-317
    • Lloyd, C.1    Silvestri, G.A.2
  • 3
    • 0033966716 scopus 로고    scopus 로고
    • The international system for staging lung cancer
    • Mountain CF. The international system for staging lung cancer. Semin Surg Oncol. 2000;18:106-115.
    • (2000) Semin Surg Oncol , vol.18 , pp. 106-115
    • Mountain, C.F.1
  • 4
    • 0027207665 scopus 로고
    • Induction chemotherapy for locally advanced non-small cell lung cancer
    • Shepherd FA Induction chemotherapy for locally advanced non-small cell lung cancer. Ann Thorac Surg 1993;55:1585-1592
    • (1993) Ann Thorac Surg , vol.55 , pp. 1585-1592
    • Shepherd, F.A.1
  • 5
    • 0027526907 scopus 로고
    • Surgical resection of stage IIIA and stage IIIB non-small-cell lung cancer after concurrent induction chemoradiotherapy: A Southwest Oncology Group trial
    • Rusch VW, Albain KS, Crowley JJ, et al. Surgical resection of stage IIIA and stage IIIB non-small-cell lung cancer after concurrent induction chemoradiotherapy: a Southwest Oncology Group trial J Thorac Cardiovasc Surg. 1993;105: 97-104.
    • (1993) J Thorac Cardiovasc Surg , vol.105 , pp. 97-104
    • Rusch, V.W.1    Albain, K.S.2    Crowley, J.J.3
  • 6
    • 0023885619 scopus 로고
    • Mediastinal nodes in bronchogenic carcinoma comparison between CT and mediastinoscopy
    • Staples CA, Muller NL, Miller RR, Evans KG, Nelems B. Mediastinal nodes in bronchogenic carcinoma comparison between CT and mediastinoscopy Radiology 1988;167:367-372.
    • (1988) Radiology , vol.167 , pp. 367-372
    • Staples, C.A.1    Muller, N.L.2    Miller, R.R.3    Evans, K.G.4    Nelems, B.5
  • 7
    • 0026556594 scopus 로고
    • Lung cancer staging: Efficacy of CT
    • Friedman PJ Lung cancer staging: efficacy of CT. Radiology. 1992;182:307-309.
    • (1992) Radiology , vol.182 , pp. 307-309
    • Friedman, P.J.1
  • 8
    • 0029045863 scopus 로고
    • New staging investigations for lung cancer what will they have to offer to be clinically useful?
    • Brown JS, Rudd R. New staging investigations for lung cancer what will they have to offer to be clinically useful? Eur J Nucl Med. 1995;22:497-498.
    • (1995) Eur J Nucl Med. , vol.22 , pp. 497-498
    • Brown, J.S.1    Rudd, R.2
  • 9
    • 0037140187 scopus 로고    scopus 로고
    • Effectiveness of positron emission tomography in the preoperative assessment of patients with suspected non-small-cell lung cancer: The PLUS multicentre trial
    • van Tinteren H, Hoekstra OS, Smit EF, et al Effectiveness of positron emission tomography in the preoperative assessment of patients with suspected non-small-cell lung cancer: the PLUS multicentre trial. Lancet. 2002;359:1388-1392.
    • (2002) Lancet , vol.359 , pp. 1388-1392
    • Van Tinteren, H.1    Hoekstra, O.S.2    Smit, E.F.3
  • 10
    • 0025923318 scopus 로고
    • 201Tl SPECT in the detection of mediastinal lymph node metastases from lung cancer
    • 201Tl SPECT in the detection of mediastinal lymph node metastases from lung cancer. Nucl Med Commun. 1991;12: 779-792.
    • (1991) Nucl Med Commun , vol.12 , pp. 779-792
    • Tonami, N.1    Yokoyama, K.2    Taki, J.3
  • 11
    • 0027965820 scopus 로고
    • Mediastinal lymph node metastasis from lung cancer: Evaluation with Tl-201 SPECT - Comparison with CT
    • Yokoi K, Okuyama A, Mori K, et al. Mediastinal lymph node metastasis from lung cancer: evaluation with Tl-201 SPECT - comparison with CT. Radiology. 1994;192:813-817.
    • (1994) Radiology , vol.192 , pp. 813-817
    • Yokoi, K.1    Okuyama, A.2    Mori, K.3
  • 12
    • 0030160533 scopus 로고    scopus 로고
    • Assessment of mediastinal involvement in lung cancer with technetium-99m-sestamibi SPECT
    • Chiti A, Maffioli LS, Infante M, et al. Assessment of mediastinal involvement in lung cancer with technetium-99m-sestamibi SPECT. J Nucl Med. 1996;37:938-942.
    • (1996) J Nucl Med , vol.37 , pp. 938-942
    • Chiti, A.1    Maffioli, L.S.2    Infante, M.3
  • 14
    • 0027514338 scopus 로고
    • Technetium-99m-1,2-bis[bis(2-ethoxyethyl) phosphino]ethane, human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent
    • Higley B, Smith FW, Smith T, et al Technetium-99m-1,2-bis[bis(2- ethoxyethyl) phosphino]ethane, human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent. J Nucl Med. 1993;34:30-38.
    • (1993) J Nucl Med , vol.34 , pp. 30-38
    • Higley, B.1    Smith, F.W.2    Smith, T.3
  • 15
    • 0024582126 scopus 로고
    • Technetium-99m hexakis 2-methoxyisobutyl isonitrile: Human biodistribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging
    • Wackers FJT, Berman DS, Maddahi J, et al Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med. 1989;30:301-311.
    • (1989) J Nucl Med , vol.30 , pp. 301-311
    • Wackers, F.J.T.1    Berman, D.S.2    Maddahi, J.3
  • 16
    • 0033637933 scopus 로고    scopus 로고
    • Use of myocardial imaging agents for tumour diagnosis a success story?
    • Shomacker K, Schicha H. Use of myocardial imaging agents for tumour diagnosis a success story? Eur J Nucl Med 2000;27:1845-1863
    • (2000) Eur J Nucl Med , vol.27 , pp. 1845-1863
    • Shomacker, K.1    Schicha, H.2
  • 19
    • 0033974627 scopus 로고    scopus 로고
    • Noninvasive clinical staging modalities for lung cancer
    • Lau CL, Harpole DH. Noninvasive clinical staging modalities for lung cancer. Semin Surg Oncol. 2000;18:116-123
    • (2000) Semin Surg Oncol , vol.18 , pp. 116-123
    • Lau, C.L.1    Harpole, D.H.2
  • 20
    • 0028273881 scopus 로고
    • Staging of mediastinal non-small cell lung cancer with FDG PET, CT, and fusion images: Preliminary prospective evaluation
    • Wahl RL, Quint LE, Greenough RL, Meyer CR, White RI, Orringer MB Staging of mediastinal non-small cell lung cancer with FDG PET, CT, and fusion images: preliminary prospective evaluation. Radiology. 1994;191:371-377.
    • (1994) Radiology , vol.191 , pp. 371-377
    • Wahl, R.L.1    Quint, L.E.2    Greenough, R.L.3    Meyer, C.R.4    White, R.I.5    Orringer, M.B.6
  • 21
    • 0026012812 scopus 로고
    • CT and MR imaging in staging non-small cell bronchogenic carcinoma: Report of the Radiologic Diagnostic Oncology Group
    • Webb WR, Gatsonis C, Zerhouni EA, et al. CT and MR imaging in staging non-small cell bronchogenic carcinoma: report of the Radiologic Diagnostic Oncology Group. Radiology. 1991;178:705-713.
    • (1991) Radiology , vol.178 , pp. 705-713
    • Webb, W.R.1    Gatsonis, C.2    Zerhouni, E.A.3
  • 23
    • 0009747127 scopus 로고    scopus 로고
    • A simulation tool for modeling cost effectiveness with applications for determining the cost effective role of nuclear medicine studies in lung and breast cancer
    • Gambhir SS, Gupta P, Allen P, Hoh C, Maddhai J, Phelps ME. A simulation tool for modeling cost effectiveness with applications for determining the cost effective role of nuclear medicine studies in lung and breast cancer. J Nucl Med. 1996;37:1428-1434
    • (1996) J Nucl Med , vol.37 , pp. 1428-1434
    • Gambhir, S.S.1    Gupta, P.2    Allen, P.3    Hoh, C.4    Maddhai, J.5    Phelps, M.E.6
  • 24
    • 0029743649 scopus 로고    scopus 로고
    • Uptake of technetium-99m-tetrofosmin, technetium-99m-mibi and thallium-201 in tumor cell lines
    • Arbab AS, Koizumi K, Toyama K, Araki T. Uptake of technetium-99m- tetrofosmin, technetium-99m-mibi and thallium-201 in tumor cell lines. J Nucl Med 1996;37:1551-1556
    • (1996) J Nucl Med , vol.37 , pp. 1551-1556
    • Arbab, A.S.1    Koizumi, K.2    Toyama, K.3    Araki, T.4
  • 25
    • 0036252606 scopus 로고    scopus 로고
    • Detecting mediastinal lymph node metastases in non-small-cell lung cancer using a combination of technetium-99m tetrofosmin chest single photon emission computed tomography and chest computed tomography
    • Shiun SC, Sun SS, Hsu NY, Kao CH, Lin CC, Lee CC. Detecting mediastinal lymph node metastases in non-small-cell lung cancer using a combination of technetium-99m tetrofosmin chest single photon emission computed tomography and chest computed tomography Cancer Invest. 2002;20:311-317.
    • (2002) Cancer Invest , vol.20 , pp. 311-317
    • Shiun, S.C.1    Sun, S.S.2    Hsu, N.Y.3    Kao, C.H.4    Lin, C.C.5    Lee, C.C.6
  • 26
    • 0037085644 scopus 로고    scopus 로고
    • 99mTc-Tetrofosmin scintigraphy in lung carcinoma staging and follow-up evaluations
    • 99mTc-Tetrofosmin scintigraphy in lung carcinoma staging and follow-up evaluations. Cancer. 2002;94:1796-1807.
    • (2002) Cancer , vol.94 , pp. 1796-1807
    • Buccheri, G.1    Biggi, A.2    Ferrigno, D.3    Francini, A.4
  • 27
    • 0034130192 scopus 로고    scopus 로고
    • Spatial and temporal registration of CT and SPECT images: Development and validation of a technique for in vivo three-dimensional semiquantitative analysis of bone
    • Bernstein MP, Caldwell CB, Antonyshyn OM, Cooper PW, Ehrlich LE. Spatial and temporal registration of CT and SPECT images: development and validation of a technique for in vivo three-dimensional semiquantitative analysis of bone J Nucl Med. 2000;41:1075-1081.
    • (2000) J Nucl Med , vol.41 , pp. 1075-1081
    • Bernstein, M.P.1    Caldwell, C.B.2    Antonyshyn, O.M.3    Cooper, P.W.4    Ehrlich, L.E.5
  • 28
    • 0028820635 scopus 로고
    • Fusion of immunoscintigraphy single photon emission computed tomography (SPECT) with CT of the chest in patients with non-small cell lung cancer
    • Katyal S, Kramer EL, Noz ME, McCauley D, Chachoua A, Steineld A. Fusion of immunoscintigraphy single photon emission computed tomography (SPECT) with CT of the chest in patients with non-small cell lung cancer Cancer Res 1995;55(23 suppl):5759s-5763s
    • (1995) Cancer Res , vol.55 , Issue.23 SUPPL.
    • Katyal, S.1    Kramer, E.L.2    Noz, M.E.3    McCauley, D.4    Chachoua, A.5    Steineld, A.6
  • 29
    • 0034043247 scopus 로고    scopus 로고
    • Gamma camera-mounted anatomical x-ray tomography technology, system characteristics and first images
    • Bocher M, Balan A, Krausz Y, et al. Gamma camera-mounted anatomical x-ray tomography technology, system characteristics and first images. Eur J Nucl Med. 2000;27:619-627.
    • (2000) Eur J Nucl Med , vol.27 , pp. 619-627
    • Bocher, M.1    Balan, A.2    Krausz, Y.3
  • 30
    • 1542723335 scopus 로고    scopus 로고
    • A combined SPET/CT imaging system for functional anatomical mapping: Initial clinical applications
    • Schillaci O, Danieli R, Picardi V, et al. A combined SPET/CT imaging system for functional anatomical mapping: initial clinical applications [abstract] Eur J Nucl Med. 2002;29(suppl 1):S94.
    • (2002) Eur J Nucl Med , vol.29 , Issue.1 SUPPL.
    • Schillaci, O.1    Danieli, R.2    Picardi, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.