메뉴 건너뛰기




Volumn 56, Issue 6, 2003, Pages 32-41

Noise-reduction circuitry in hearing aids: (2) goals and current strategies

(1)  Schum, Donald J a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; AMPLITUDE MODULATION; ANNOYANCE; ARTICLE; AUDITORY MASKING; ENERGY; FATIGUE; HEARING AID; LOW FREQUENCY NOISE; NOISE REDUCTION; PERCEPTION DEAFNESS; SIGNAL PROCESSING; SIGNAL PROCESSOR; SPEECH;

EID: 0141744804     PISSN: 07457472     EISSN: 15425991     Source Type: Journal    
DOI: 10.1097/01.HJ.0000294049.75608.1c     Document Type: Article
Times cited : (26)

References (13)
  • 1
    • 0000545838 scopus 로고    scopus 로고
    • Speech understanding in background noise
    • Valente M, ed., New York: Thieme Medical Publishers
    • Schum D: Speech understanding in background noise. In Valente M, ed., Hearing Aids: Standards, Options, and Limitations. New York: Thieme Medical Publishers, 1996.
    • (1996) Hearing Aids: Standards, Options, and Limitations
    • Schum, D.1
  • 2
    • 84889381426 scopus 로고
    • Methods for the calculation and use of the Articulation Index
    • Kryter K: Methods for the calculation and use of the Articulation Index. J Acoust Soc Am 1962;34:1689-1697.
    • (1962) J Acoust Soc Am , vol.34 , pp. 1689-1697
    • Kryter, K.1
  • 3
    • 0025365922 scopus 로고
    • Upward spread of masking, hearing loss, and speech recognition in young and elderly listeners
    • Klein A, Mills J, Adkins W: Upward spread of masking, hearing loss, and speech recognition in young and elderly listeners. J Acoust Soc Am 1990;87:1266-1271.
    • (1990) J Acoust Soc Am , vol.87 , pp. 1266-1271
    • Klein, A.1    Mills, J.2    Adkins, W.3
  • 4
    • 0026671166 scopus 로고
    • Performance with an adaptive frequency response hearing aid in a sample of elderly hearing-impaired listeners
    • Gordon-Salant S, Sherlock L: Performance with an adaptive frequency response hearing aid in a sample of elderly hearing-impaired listeners. Ear Hear 1992;13:255-262.
    • (1992) Ear Hear , vol.13 , pp. 255-262
    • Gordon-Salant, S.1    Sherlock, L.2
  • 5
    • 0026134710 scopus 로고
    • Understanding the speech understanding problems of the hearing impaired
    • Humes L: Understanding the speech understanding problems of the hearing impaired. JAAA 1991;2:59-69.
    • (1991) JAAA , vol.2 , pp. 59-69
    • Humes, L.1
  • 6
    • 0030750654 scopus 로고    scopus 로고
    • A comparison of the benefit of well-fit linear hearing aids and instruments with automatic reductions of low-frequency gain
    • Humes L, Christensen L, Bess F, Headley-Williams A: A comparison of the benefit of well-fit linear hearing aids and instruments with automatic reductions of low-frequency gain. J Sp Lang Hear Res 1997;40:666-685.
    • (1997) J Sp Lang Hear Res , vol.40 , pp. 666-685
    • Humes, L.1    Christensen, L.2    Bess, F.3    Headley-Williams, A.4
  • 7
    • 0037841884 scopus 로고    scopus 로고
    • Evaluation of the noise reduction system in a commercial hearing aid
    • Alacantra J, Moore B, Kuhel V, Launer S: Evaluation of the noise reduction system in a commercial hearing aid. Int J Audiol 2003;42:34-42.
    • (2003) Int J Audiol , vol.42 , pp. 34-42
    • Alacantra, J.1    Moore, B.2    Kuhel, V.3    Launer, S.4
  • 8
    • 0033662533 scopus 로고    scopus 로고
    • Field trials using a digital hearing aid with active noise reduction and dual-microphone directionality
    • Boymans M, Dreschler W: Field trials using a digital hearing aid with active noise reduction and dual-microphone directionality. Audiology 2000;39:260-268.
    • (2000) Audiology , vol.39 , pp. 260-268
    • Boymans, M.1    Dreschler, W.2
  • 9
    • 0029072928 scopus 로고
    • Evaluation of a speech enhancement strategy with normal-hearing and hearing-impaired listeners
    • Jamieson D, Brennan R, Cornelisse L: Evaluation of a speech enhancement strategy with normal-hearing and hearing-impaired listeners. Ear Hear 1995;16:274-286.
    • (1995) Ear Hear , vol.16 , pp. 274-286
    • Jamieson, D.1    Brennan, R.2    Cornelisse, L.3
  • 11
    • 0141581663 scopus 로고    scopus 로고
    • Initial clinical verification of a DSP instrument
    • Schum D, Pogash R: Initial clinical verification of a DSP instrument. Hear Rev 2002;9(9):48-51.
    • (2002) Hear Rev , vol.9 , Issue.9 , pp. 48-51
    • Schum, D.1    Pogash, R.2
  • 12
    • 85026161781 scopus 로고    scopus 로고
    • Audiology Online, January 17
    • Schum D: Annoyance and hearing aids. Audiology Online, January 17, 2001. www.audiologyonline.com/audiology/newroot/articles/arc_disp.asp/id=24/&catid=1
    • (2001) Annoyance and hearing aids
    • Schum, D.1
  • 13
    • 0034740182 scopus 로고    scopus 로고
    • Effect of preferred volume setting on speech audibility in different hearing aid circuits
    • Souza P, Kitch V: Effect of preferred volume setting on speech audibility in different hearing aid circuits. JAAA 2001;12:415-422.
    • (2001) JAAA , vol.12 , pp. 415-422
    • Souza, P.1    Kitch, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.