메뉴 건너뛰기




Volumn 45, Issue 1, 2003, Pages 43-65

Bayesian measures of the minimum detectable concentration of an immunoassay

Author keywords

Assay; Bayesian analysis; Minimal detectable concentration; Nonlinear regression; Predictive inference

Indexed keywords


EID: 0141687251     PISSN: 13691473     EISSN: None     Source Type: Journal    
DOI: 10.1111/1467-842x.00260     Document Type: Article
Times cited : (4)

References (21)
  • 2
    • 0033638703 scopus 로고    scopus 로고
    • Applications of likelihood asymptotics for nonlinear regression in herbicide bioassays
    • BELLIO, R., JENSEN, J.E. & SEIDEN, P. (2000). Applications of likelihood asymptotics for nonlinear regression in herbicide bioassays. Biometrics 56, 1204-1212.
    • (2000) Biometrics , vol.56 , pp. 1204-1212
    • Bellio, R.1    Jensen, J.E.2    Seiden, P.3
  • 3
    • 0029887233 scopus 로고    scopus 로고
    • Defining the smallest analyte concentration an immunoassay can measure
    • BROWN, E.N., MCDERMOTT, T.J., BLOCK, K.J. & MCCOLLOM, A.D. (1996). Defining the smallest analyte concentration an immunoassay can measure. Clin. Chem. 42, 893-903.
    • (1996) Clin. Chem. , vol.42 , pp. 893-903
    • Brown, E.N.1    McDermott, T.J.2    Block, K.J.3    McCollom, A.D.4
  • 4
    • 23544462582 scopus 로고
    • Limits for qualitative detection and quantitative determination
    • CURRIE, L.A. (1968). Limits for qualitative detection and quantitative determination. Anal. Chem. 40, 586-593.
    • (1968) Anal. Chem. , vol.40 , pp. 586-593
    • Currie, L.A.1
  • 5
    • 0001365906 scopus 로고
    • Variance functions and the minimum detectable concentration in assays
    • DAVIDIAN, M., CARROLL, R.J. & SMITH, W. (1988). Variance functions and the minimum detectable concentration in assays. Biometrika 75, 549-556.
    • (1988) Biometrika , vol.75 , pp. 549-556
    • Davidian, M.1    Carroll, R.J.2    Smith, W.3
  • 6
    • 0002111030 scopus 로고
    • Chapter 1: Principles, ed. D.G. Wild. New York: Stockton Press
    • DAVIES, C.J. (1994). Chapter 1: Principles. In The Immunoassay Handbook, ed. D.G. Wild, pp. 3-47. New York: Stockton Press.
    • (1994) The Immunoassay Handbook , pp. 3-47
    • Davies, C.J.1
  • 7
    • 0017027980 scopus 로고
    • Radioligand assay
    • FINNEY, D.J. (1976). Radioligand assay. Biometrics 32, 721-740.
    • (1976) Biometrics , vol.32 , pp. 721-740
    • Finney, D.J.1
  • 8
    • 84988053654 scopus 로고
    • On the curtailment of sampling
    • GEISSER, S. (1992). On the curtailment of sampling. Canad. J. Statist. 20, 297-309.
    • (1992) Canad. J. Statist. , vol.20 , pp. 297-309
    • Geisser, S.1
  • 9
    • 38248999974 scopus 로고
    • Bayesian interim analysis of censored exponential observations
    • GEISSER, S. (1993). Bayesian interim analysis of censored exponential observations. Statist. Probab. Lett. 18, 163-168.
    • (1993) Statist. Probab. Lett. , vol.18 , pp. 163-168
    • Geisser, S.1
  • 10
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • HANLEY, J.A. & MCNEIL, B.J. (1982). The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 143, 29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 11
    • 77956890234 scopus 로고
    • Monte-Carlo sampling methods using Markov Chains and their applications
    • HASTINGS, W.K. (1970). Monte-Carlo sampling methods using Markov Chains and their applications. Biometrika 57, 97-109.
    • (1970) Biometrika , vol.57 , pp. 97-109
    • Hastings, W.K.1
  • 15
    • 0020734724 scopus 로고
    • Determining the lowest limit of reliable assay measurement
    • OPPENHEIMER, L., CAPIZZI, T.P., WEPPELMAN, R.M. & MEHTA, H. (1983). Determining the lowest limit of reliable assay measurement. Anal. Chem. 55, 638-643.
    • (1983) Anal. Chem. , vol.55 , pp. 638-643
    • Oppenheimer, L.1    Capizzi, T.P.2    Weppelman, R.M.3    Mehta, H.4
  • 16
    • 0015396103 scopus 로고
    • A Bayesian approach to bioassay
    • RAMSEY, F.L. (1972). A Bayesian approach to bioassay. Biometrics 28, 841-858.
    • (1972) Biometrics , vol.28 , pp. 841-858
    • Ramsey, F.L.1
  • 18
    • 0018127669 scopus 로고
    • Statistical estimation of the minimal detectable concentration ("sensitivity") for radioligand assays
    • RODBARD, D. (1978). Statistical estimation of the minimal detectable concentration ("sensitivity") for radioligand assays. Anal. Biochem. 90, 1-12.
    • (1978) Anal. Biochem. , vol.90 , pp. 1-12
    • Rodbard, D.1
  • 19
    • 0025006444 scopus 로고
    • Use and abuse of imprecision profiles: Some pitfalls illustrated by computing and plotting confidence intervals
    • SADLER, W.A. & SMITH, M.H. (1990). Use and abuse of imprecision profiles: some pitfalls illustrated by computing and plotting confidence intervals. Clin. Chem. 36, 1346-1350.
    • (1990) Clin. Chem. , vol.36 , pp. 1346-1350
    • Sadler, W.A.1    Smith, M.H.2
  • 20
    • 0026657025 scopus 로고
    • Minimum distinguishable difference in concentration: A clinically oriented translation of assay precision summaries
    • SADLER, W. A., MURRAY, L.M. & TURNER, J.G. (1992). Minimum distinguishable difference in concentration: a clinically oriented translation of assay precision summaries. Clin. Chem. 38, 1773-1778.
    • (1992) Clin. Chem. , vol.38 , pp. 1773-1778
    • Sadler, W.A.1    Murray, L.M.2    Turner, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.