메뉴 건너뛰기




Volumn 16, Issue 3, 2003, Pages 325-339

The effect of breathing pattern on nebulizer drug delivery

Author keywords

Deposition; Sine wave; Square wave; Tidal breathing; Wet aerosol

Indexed keywords

AEROSOL; ARTICLE; BREATHING; COMPUTER MODEL; DRUG DELIVERY SYSTEM; EXHALATION; IN VITRO STUDY; INHALATION; LUNG; NEBULIZATION; NEBULIZER; PARTICLE SIZE; SIMULATION; TIDAL VOLUME;

EID: 0141651952     PISSN: 08942684     EISSN: None     Source Type: Journal    
DOI: 10.1089/089426803769017677     Document Type: Article
Times cited : (40)

References (27)
  • 1
    • 85012535540 scopus 로고
    • Drug delivery by nebulization: "Reality testing."
    • Smaldone, G.C. 1994. Drug delivery by nebulization: "reality testing." J. Aerosol Med. 7:213-216.
    • (1994) J. Aerosol Med. , vol.7 , pp. 213-216
    • Smaldone, G.C.1
  • 2
    • 0033918289 scopus 로고    scopus 로고
    • Validation of a new breathing simulator generating and measuring inhaled aerosol with adult breathing patterns
    • Nikander, K., J. Denyer, M. Everard, et al. 2000. Validation of a new breathing simulator generating and measuring inhaled aerosol with adult breathing patterns. J. Aerosol Med. 13:139-146.
    • (2000) J. Aerosol Med. , vol.13 , pp. 139-146
    • Nikander, K.1    Denyer, J.2    Everard, M.3
  • 3
    • 0030968138 scopus 로고    scopus 로고
    • Aerosol delivery during continuous nebulization
    • McPeck, M., R. Tandon, K. Hughes, et al. 1997. Aerosol delivery during continuous nebulization. Chest 111:1200-1205.
    • (1997) Chest , vol.111 , pp. 1200-1205
    • McPeck, M.1    Tandon, R.2    Hughes, K.3
  • 4
    • 0033062147 scopus 로고    scopus 로고
    • Effects of equipment dead space and pediatric breathing patterns on inhaled mass of nebulized budesonide
    • Nikander, K., J. Denyer, and G.C. Smaldone. 1999. Effects of equipment dead space and pediatric breathing patterns on inhaled mass of nebulized budesonide. J. Aerosol Med. 12:67-73.
    • (1999) J. Aerosol Med. , vol.12 , pp. 67-73
    • Nikander, K.1    Denyer, J.2    Smaldone, G.C.3
  • 5
    • 0029129187 scopus 로고
    • Drug nebulizer design and performance: Breath enhanced jet vs. constant output jet vs. ultrasonic
    • Dennis, J.H. 1995. Drug nebulizer design and performance: breath enhanced jet vs. constant output jet vs. ultrasonic. J. Aerosol Med. 8:277-280.
    • (1995) J. Aerosol Med. , vol.8 , pp. 277-280
    • Dennis, J.H.1
  • 6
    • 0026728835 scopus 로고
    • Delivery of a nebulized aerosol to a lung model during mechanical ventilation
    • O'Doherty, M.J., S.H.L. Thomas, C.J. Page, et al. 1992. Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Am. Rev. Respir. Dis. 146: 383-388.
    • (1992) Am. Rev. Respir. Dis. , vol.146 , pp. 383-388
    • O'Doherty, M.J.1    Thomas, S.H.L.2    Page, C.J.3
  • 7
    • 0026795105 scopus 로고
    • Nebulizer function during mechanical ventilation
    • O'Riordan, T.G., M.J. Greco, R.J. Perry, et al. 1992. Nebulizer function during mechanical ventilation. Am. Rev. Respir. Dis. 145:1117-1122.
    • (1992) Am. Rev. Respir. Dis. , vol.145 , pp. 1117-1122
    • O'Riordan, T.G.1    Greco, M.J.2    Perry, R.J.3
  • 9
    • 0030956723 scopus 로고    scopus 로고
    • Respiratory drug delivery
    • Anderson, P.J. 1997. Respiratory drug delivery. Chest 111:1155-1156.
    • (1997) Chest , vol.111 , pp. 1155-1156
    • Anderson, P.J.1
  • 10
    • 0024500036 scopus 로고
    • Individuality of breathing pattern in adults assessed over time
    • Benchetrit, G., S.A. Shea, T.P. Dinh, et al. 1989. Individuality of breathing pattern in adults assessed over time. Respir. Physiol. 75:199-210.
    • (1989) Respir. Physiol. , vol.75 , pp. 199-210
    • Benchetrit, G.1    Shea, S.A.2    Dinh, T.P.3
  • 11
    • 0020612364 scopus 로고
    • Breathing patterns 1: Normal subjects
    • Tobin, M.J., T.S. Chadha, G. Jenouri, et al. 1983. Breathing patterns 1: Normal subjects. Chest 84:202-205.
    • (1983) Chest , vol.84 , pp. 202-205
    • Tobin, M.J.1    Chadha, T.S.2    Jenouri, G.3
  • 12
    • 0020619498 scopus 로고
    • Breathing patterns 2: Diseased subjects
    • Tobin, M.J., T.S. Chadha, G. Jenouri, et al. 1983. Breathing patterns 2: Diseased subjects. Chest 84:286-294.
    • (1983) Chest , vol.84 , pp. 286-294
    • Tobin, M.J.1    Chadha, T.S.2    Jenouri, G.3
  • 13
    • 0019202264 scopus 로고
    • Effects of breathing through external dead space on ventilation at rest and during exercise
    • Sackner, J.D., A.J. Nixon, B. Davis, et al. 1980. Effects of breathing through external dead space on ventilation at rest and during exercise. Am. Rev. Respir. Dis. 122:933-940.
    • (1980) Am. Rev. Respir. Dis. , vol.122 , pp. 933-940
    • Sackner, J.D.1    Nixon, A.J.2    Davis, B.3
  • 14
    • 0026640792 scopus 로고
    • Breathing patterns during varied activities. ii
    • Paek, D., and D. McCool. 1992. Breathing patterns during varied activities. ii. J. Appl. Physiol. 73:887-893.
    • (1992) J. Appl. Physiol. , vol.73 , pp. 887-893
    • Paek, D.1    McCool, D.2
  • 15
    • 0020470038 scopus 로고
    • Changes in respiratory pattern resulting from the use of a facemask to record respiration in newborn infants
    • Fleming, P., M.R. Levine, and A. Goncalves. 1982. Changes in respiratory pattern resulting from the use of a facemask to record respiration in newborn infants. Pediatr. Res. 16:1031-1034.
    • (1982) Pediatr. Res. , vol.16 , pp. 1031-1034
    • Fleming, P.1    Levine, M.R.2    Goncalves, A.3
  • 16
    • 0018819738 scopus 로고
    • Effects of respiratory apparatus on breathing pattern
    • Askanazi, J., P.A. Silverberg, R.J. Foster, et al. 1980. Effects of respiratory apparatus on breathing pattern. J. Appl. Physiol. 48:577-580.
    • (1980) J. Appl. Physiol. , vol.48 , pp. 577-580
    • Askanazi, J.1    Silverberg, P.A.2    Foster, R.J.3
  • 17
    • 0015384501 scopus 로고
    • Changes in tidal volume, frequency, and ventilation induced by their measurement
    • Gilbert, R., J.H. Auchincloss Jr., J. Brodsky, et al. 1972. Changes in tidal volume, frequency, and ventilation induced by their measurement. J. Appl. Physiol. 33: 252-254.
    • (1972) J. Appl. Physiol. , vol.33 , pp. 252-254
    • Gilbert, R.1    Auchincloss J.H., Jr.2    Brodsky, J.3
  • 18
    • 0022357356 scopus 로고
    • Separation of factors responsible for change in breathing pattern induced by instrumentation
    • Perez, W., and M. Tobin. 1985. Separation of factors responsible for change in breathing pattern induced by instrumentation. J. Appl. Physiol. 59:1515-1520.
    • (1985) J. Appl. Physiol. , vol.59 , pp. 1515-1520
    • Perez, W.1    Tobin, M.2
  • 20
    • 0001079636 scopus 로고    scopus 로고
    • Can models be trusted to subdivide lung deposition into alveolar and tracheobronchial fractions?
    • R.N. Dalby, P.R. Byron, and S.J. Farr, Eds. Interpharm Press, Buffalo Grove, IL
    • Finlay, W.H., M. Hoskinson, and K.W. Stapleton. 1998. Can models be trusted to subdivide lung deposition into alveolar and tracheobronchial fractions? In R.N. Dalby, P.R. Byron, and S.J. Farr, Eds. Respiratory Drug Delivery VI. Interpharm Press, Buffalo Grove, IL, 235-242.
    • (1998) Respiratory Drug Delivery VI , pp. 235-242
    • Finlay, W.H.1    Hoskinson, M.2    Stapleton, K.W.3
  • 21
    • 0031836818 scopus 로고    scopus 로고
    • Variations in predicted regional lung deposition of salbutamol sulphate between 19 nebulizer models
    • Finlay, W.H., K.W. Stapleton, and P. Zuberbuhler. 1998. Variations in predicted regional lung deposition of salbutamol sulphate between 19 nebulizer models. J. Aerosol Med. 11:65-80.
    • (1998) J. Aerosol Med. , vol.11 , pp. 65-80
    • Finlay, W.H.1    Stapleton, K.W.2    Zuberbuhler, P.3
  • 22
    • 0141479545 scopus 로고    scopus 로고
    • A fully Eulerian approach to the simulation of volatile/hygroscopic aerosol
    • G.E. Scheider, Ed, Waterloo, ON, May 27-29, 2001
    • Lange, C.F., and W.H. Finlay. 2001. A fully Eulerian approach to the simulation of volatile/hygroscopic aerosol. In G.E. Scheider, Ed. Proceedings of the Ninth Annual Conference of the CFD Society of Canada, pp. 279-283, Waterloo, ON, May 27-29, 2001.
    • (2001) Proceedings of the Ninth Annual Conference of the CFD Society of Canada , pp. 279-283
    • Lange, C.F.1    Finlay, W.H.2
  • 24
    • 0029587238 scopus 로고
    • The effect of ambient relative humidity on regional dosages delivered by a jet nebulizer
    • Prokop, R.M., W.H. Finlay, K.W. Stapleton, et al. 1995. The effect of ambient relative humidity on regional dosages delivered by a jet nebulizer. J. Aerosol Med. 8:363-372.
    • (1995) J. Aerosol Med. , vol.8 , pp. 363-372
    • Prokop, R.M.1    Finlay, W.H.2    Stapleton, K.W.3
  • 25
    • 0031646978 scopus 로고    scopus 로고
    • Estimating the type of hygroscopic behaviour exhibited by aqueous droplets
    • Finlay, W.H. 1998. Estimating the type of hygroscopic behaviour exhibited by aqueous droplets. J. Aerosol Med. 11:221-229.
    • (1998) J. Aerosol Med. , vol.11 , pp. 221-229
    • Finlay, W.H.1
  • 26
    • 0028673374 scopus 로고
    • An in vitro method for determining regional dosages delivered by jet nebulizers
    • Stapleton, K.W., W.H. Finlay, and P. Zuberbuhler. 1994. An in vitro method for determining regional dosages delivered by jet nebulizers. J. Aerosol Med. 7:325-344.
    • (1994) J. Aerosol Med. , vol.7 , pp. 325-344
    • Stapleton, K.W.1    Finlay, W.H.2    Zuberbuhler, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.