Volumn 145, Issue 2, 2003, Pages 67-77

A Novel Method for Active Filter Current Regulation Using Deadbeat Control

Author keywords

Active filter; Deadbeat control; Digital control; PWM inverter; Source current detection

Indexed keywords

CONTROL SYSTEM ANALYSIS; ELECTRIC CURRENTS; ELECTRIC INVERTERS; ELECTRIC POTENTIAL;

EID: 0141637337     PISSN: 04247760     EISSN: None     Source Type: Journal    
DOI: 10.1002/eej.10201     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 85009576654 scopus 로고
    • Compensation characteristics of shunt active and series active power filter
    • Peng FZ, et al. Compensation characteristics of shunt active and series active power filter. Trans IEE Japan 1993;113-D:33-39.
    • (1993) Trans IEE Japan , vol.113 D , pp. 33-39
    • Peng, F.Z.1
  • 2
    • 0001676524 scopus 로고    scopus 로고
    • Control strategy and site selection of a shunt active filter for installation on a power distribution system
    • Akagi H. Control strategy and site selection of a shunt active filter for installation on a power distribution system. Trans IEE Japan 1996;116-D:285-293.
    • (1996) Trans IEE Japan , vol.116 D , pp. 285-293
    • Akagi, H.1
  • 3
    • 85015081501 scopus 로고    scopus 로고
    • Application of internal-model-principle to current control for active power filters
    • Yoda T, Fukuda S. Application of internal-model-principle to current control for active power filters. Trans IEE Japan 2000;120-D:1440-1446.
    • (2000) Trans IEE Japan , vol.120 D , pp. 1440-1446
    • Yoda, T.1    Fukuda, S.2
  • 4
    • 85007825545 scopus 로고
    • Active filter with reduced pulsation of instantaneous source current
    • Ohnishi T, Yamauchi H. Active filter with reduced pulsation of instantaneous source current. Trans IEE Japan 1991;111-D:921-929.
    • (1991) Trans IEE Japan , vol.111 D , pp. 921-929
    • Ohnishi, T.1    Yamauchi, H.2
  • 5
    • 85009010491 scopus 로고    scopus 로고
    • Considerations of a fully digital controlled AF for installation on power distribution system
    • Jintakosonwit P, et al. Considerations of a fully digital controlled AF for installation on power distribution system. Trans IEE Japan 2001;121-D:316-324.
    • (2001) Trans IEE Japan , vol.121 D , pp. 316-324
    • Jintakosonwit, P.1
  • 6
    • 85006863128 scopus 로고
    • Compensation characteristics of active power filter using multi-series voltage source PWM converters
    • Akagi H, et al. Compensation characteristics of active power filter using multi-series voltage source PWM converters. Trans IEE Japan 1986;106-B:563-570.
    • (1986) Trans IEE Japan , vol.106 B , pp. 563-570
    • Akagi, H.1
  • 7
    • 0028496729 scopus 로고
    • Disturbance observer based fully digital controlled PWM inverter for CVCF operation
    • Yokoyama T, Kawamura A. Disturbance observer based fully digital controlled PWM inverter for CVCF operation. IEEE Trans Power Electron 1994;9:473-478.
    • (1994) IEEE Trans Power Electron , vol.9 , pp. 473-478
    • Yokoyama, T.1    Kawamura, A.2
  • 8
    • 85007728453 scopus 로고
    • DSP based real time output waveform synthesis for three phase PWM inverter
    • Ishihara K, Kawamura A. DSP based real time output waveform synthesis for three phase PWM inverter. Trans IEE Japan 1990;110-D:627-636.
    • (1990) Trans IEE Japan , vol.110 D , pp. 627-636
    • Ishihara, K.1    Kawamura, A.2
  • 9
    • 0141623422 scopus 로고
    • Development of linear sample model for power electronics driven by PWM inverter
    • Kawamura A. Development of linear sample model for power electronics driven by PWM inverter. IEEJ Natl Conf, No. 534, 1987.
    • (1987) IEEJ Natl Conf , vol.534
    • Kawamura, A.1
  • 10
    • 85006928980 scopus 로고    scopus 로고
    • Disturbance observer based compensation of the active filter detecting the source current harmonics
    • Hamasaki S, Kawamura A. Disturbance observer based compensation of the active filter detecting the source current harmonics. Trans IEE Japan 1999;119-D:1271-1272.
    • (1999) Trans IEE Japan , vol.119 D , pp. 1271-1272
    • Hamasaki, S.1    Kawamura, A.2
  • 11
    • 85013595683 scopus 로고    scopus 로고
    • Single-phase line current compensator based on AC line current
    • Ohnishi T. Single-phase line current compensator based on AC line current. Trans IEE Japan 1997;117-D:321-327.
    • (1997) Trans IEE Japan , vol.117 D , pp. 321-327
    • Ohnishi, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.