-
1
-
-
0029004316
-
Work of flexion after tendon repair with various suture methods: A human cadaveric study
-
Aoki M, Manske PR, Pruitt DL, Larson BJ. Work of flexion after tendon repair with various suture methods: a human cadaveric study. J Hand Surg 1995;20B:310-313.
-
(1995)
J Hand Surg
, vol.20 B
, pp. 310-313
-
-
Aoki, M.1
Manske, P.R.2
Pruitt, D.L.3
Larson, B.J.4
-
2
-
-
0035076123
-
Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs
-
Barrie KA, Tomak SL, Cholewicki J, Merrell GA, Wolfe SW. Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs. J Hand Surg 2001;26A:340-346.
-
(2001)
J Hand Surg
, vol.26 A
, pp. 340-346
-
-
Barrie, K.A.1
Tomak, S.L.2
Cholewicki, J.3
Merrell, G.A.4
Wolfe, S.W.5
-
3
-
-
0036095251
-
Comparative biomechanical performance of 4-strand core suture repair for zone II flexor tendon lacerations
-
Angeles JG, Heminger H, Mass DP. Comparative biomechanical performance of 4-strand core suture repair for zone II flexor tendon lacerations. J Hand Surg 2002;27A:508-517.
-
(2002)
J Hand Surg
, vol.27 A
, pp. 508-517
-
-
Angeles, J.G.1
Heminger, H.2
Mass, D.P.3
-
4
-
-
0032764212
-
Effect of the cross-sectional area of locking loops in flexor tendon repair
-
Hatanaka H, Manske PR. Effect of the cross-sectional area of locking loops in flexor tendon repair. J Hand Surg 1999; 24A:751-760.
-
(1999)
J Hand Surg
, vol.24 A
, pp. 751-760
-
-
Hatanaka, H.1
Manske, P.R.2
-
5
-
-
0035029720
-
Biomechanical evaluation of flexor tendon repair techniques
-
Tang JB, Wang B, Chen F, Pan CZ, Xie RG. Biomechanical evaluation of flexor tendon repair techniques. Clin Orthop 2001;386:252-259.
-
(2001)
Clin Orthop
, vol.386
, pp. 252-259
-
-
Tang, J.B.1
Wang, B.2
Chen, F.3
Pan, C.Z.4
Xie, R.G.5
-
6
-
-
0033863564
-
In vitro biomechanical evaluation of the double loop suture for flexor tendon repair
-
Veitch A, Firoozbakhsh K, Pribyl CR, McNally T. In vitro biomechanical evaluation of the double loop suture for flexor tendon repair. Clin Orthop 2000;377:228-234.
-
(2000)
Clin Orthop
, vol.377
, pp. 228-234
-
-
Veitch, A.1
Firoozbakhsh, K.2
Pribyl, C.R.3
McNally, T.4
-
7
-
-
0029118581
-
Comparative mechanical analysis of dorsal versus palmar placements of core suture for flexor tendon repairs
-
Soejima O, Diao E, Lotz JC, Hariharan JS. Comparative mechanical analysis of dorsal versus palmar placements of core suture for flexor tendon repairs. J Hand Surg 1995;20A:801-807.
-
(1995)
J Hand Surg
, vol.20 A
, pp. 801-807
-
-
Soejima, O.1
Diao, E.2
Lotz, J.C.3
Hariharan, J.S.4
-
8
-
-
0024369924
-
Flexor tendon repair: Significant gain in strength from the Halsted peripheral suture technique
-
Wade PJ, Wetherell RG, Amis AA. Flexor tendon repair: significant gain in strength from the Halsted peripheral suture technique. J Hand Surg 1989;14B:232-235.
-
(1989)
J Hand Surg
, vol.14 B
, pp. 232-235
-
-
Wade, P.J.1
Wetherell, R.G.2
Amis, A.A.3
-
9
-
-
0027518567
-
Two new methods of tendon repair: An in vitro evaluation of tensile strength and gap formation
-
Silfverskiold KL, Andersson CH. Two new methods of tendon repair: an in vitro evaluation of tensile strength and gap formation. J Hand Surg 1993;18A:58-65.
-
(1993)
J Hand Surg
, vol.18 A
, pp. 58-65
-
-
Silfverskiold, K.L.1
Andersson, C.H.2
-
10
-
-
0037348082
-
Effects of direction of tendon lacerations on strength of tendon repairs
-
Tan J, Wang B, Xu Y, Tang JB. Effects of direction of tendon lacerations on strength of tendon repairs. J Hand Surg 2003;28A:237-242.
-
(2003)
J Hand Surg
, vol.28 A
, pp. 237-242
-
-
Tan, J.1
Wang, B.2
Xu, Y.3
Tang, J.B.4
-
11
-
-
0343848522
-
In vitro studies of a new method of flexor tendon repair
-
Savage R. In vitro studies of a new method of flexor tendon repair. J Hand Surg 1985;10B:135-141.
-
(1985)
J Hand Surg
, vol.10 B
, pp. 135-141
-
-
Savage, R.1
-
12
-
-
0034948985
-
Biomechanical assessment of a new type of flexor tendon repair
-
Smith AM, Evans DM. Biomechanical assessment of a new type of flexor tendon repair. J Hand Surg 2001;26B:217-219.
-
(2001)
J Hand Surg
, vol.26 B
, pp. 217-219
-
-
Smith, A.M.1
Evans, D.M.2
-
13
-
-
0031956702
-
Mechanical strengths of tendon sutures. An in vitro comparative study of six techniques
-
Zatiti SCA, Mazzer N, Barbieri CH. Mechanical strengths of tendon sutures. An in vitro comparative study of six techniques. J Hand Surg 1998;23B:228-233.
-
(1998)
J Hand Surg
, vol.23 B
, pp. 228-233
-
-
Zatiti, S.C.A.1
Mazzer, N.2
Barbieri, C.H.3
-
14
-
-
0034836413
-
Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing
-
Tang JB, Xie RG. Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing. J Hand Surg 2001;26A:855-861.
-
(2001)
J Hand Surg
, vol.26 A
, pp. 855-861
-
-
Tang, J.B.1
Xie, R.G.2
-
15
-
-
0034833659
-
Tensile properties of suture methods for repair of partially lacerated human flexor tendon in vitro
-
Zobitz ME, Zhao C, Erhard L, Amadio PC, An KN. Tensile properties of suture methods for repair of partially lacerated human flexor tendon in vitro. J Hand Surg 2001;26A:821-827.
-
(2001)
J Hand Surg
, vol.26 A
, pp. 821-827
-
-
Zobitz, M.E.1
Zhao, C.2
Erhard, L.3
Amadio, P.C.4
An, K.N.5
-
16
-
-
0034879252
-
Comparison of postoperative early active mobilization and immobilization in vivo utilising a four-strand flexor tendon repair
-
Wada A, Kubota H, Miyanishi K, Miura H, Iwamoto Y. Comparison of postoperative early active mobilization and immobilization in vivo utilising a four-strand flexor tendon repair. J Hand Surg 2001;26B:301-306.
-
(2001)
J Hand Surg
, vol.26 B
, pp. 301-306
-
-
Wada, A.1
Kubota, H.2
Miyanishi, K.3
Miura, H.4
Iwamoto, Y.5
-
17
-
-
0035190027
-
Effects of tension direction on strength of tendon repair
-
Tang JB, Cao Y, Xie RG. Effects of tension direction on strength of tendon repair. J Hand Surg 2001;26A:1105-1110.
-
(2001)
J Hand Surg
, vol.26 A
, pp. 1105-1110
-
-
Tang, J.B.1
Cao, Y.2
Xie, R.G.3
-
18
-
-
0034994073
-
Effect of absorbable polydioxanone flexor tendon repair and restricted active mobilization in a canine model
-
Wada A, Kubota H, Akiyama T, Hatanaka H, Miura H, Iwamoto Y. Effect of absorbable polydioxanone flexor tendon repair and restricted active mobilization in a canine model. J Hand Surg 2001;26A:398-406.
-
(2001)
J Hand Surg
, vol.26 A
, pp. 398-406
-
-
Wada, A.1
Kubota, H.2
Akiyama, T.3
Hatanaka, H.4
Miura, H.5
Iwamoto, Y.6
-
19
-
-
0031405345
-
Differences between locking loops and grasping loops: Effects on 2-strand core suture
-
Hotokezaka S, Manske PR. Differences between locking loops and grasping loops: effects on 2-strand core suture. J Hand Surg 1997;22A:995-1003.
-
(1997)
J Hand Surg
, vol.22 A
, pp. 995-1003
-
-
Hotokezaka, S.1
Manske, P.R.2
-
20
-
-
0033862301
-
The role of multiple strands and locking sutures on gap formation of flexor tendon repairs during cyclic loading
-
Barrie KA, Tomak SL, Cholewicki J, Wolfe SW. The role of multiple strands and locking sutures on gap formation of flexor tendon repairs during cyclic loading. J Hand Surg 2000;25A:714-720.
-
(2000)
J Hand Surg
, vol.25 A
, pp. 714-720
-
-
Barrie, K.A.1
Tomak, S.L.2
Cholewicki, J.3
Wolfe, S.W.4
-
22
-
-
0017758331
-
Repair of flexor tendons by intratendinous tendon suture
-
Tsuge K, Ikuta Y, Matsuishi Y. Repair of flexor tendons by intratendinous tendon suture. J Hand Surg 1977;2:436-440.
-
(1977)
J Hand Surg
, vol.2
, pp. 436-440
-
-
Tsuge, K.1
Ikuta, Y.2
Matsuishi, Y.3
-
23
-
-
0024408431
-
Flexor tendon repair using a "six-strand" method of repair and early active mobilisation
-
Savage R, Risitano G. Flexor tendon repair using a "six-strand" method of repair and early active mobilisation. J Hand Surg 1989;14B:396-399.
-
(1989)
J Hand Surg
, vol.14 B
, pp. 396-399
-
-
Savage, R.1
Risitano, G.2
-
24
-
-
0028569034
-
Double and multiple looped suture tendon repair
-
Tang JB, Shi D, Gu YQ, Chen JC, Zhou B. Double and multiple looped suture tendon repair. J Hand Surg 1994;19B:699-703.
-
(1994)
J Hand Surg
, vol.19 B
, pp. 699-703
-
-
Tang, J.B.1
Shi, D.2
Gu, Y.Q.3
Chen, J.C.4
Zhou, B.5
-
25
-
-
0002288158
-
Single-cross grasp six-strand repair for acute flexor tenorrhaphy
-
Sandow MJ, McMahon MM. Single-cross grasp six-strand repair for acute flexor tenorrhaphy. Atlas Hand Clin 1996; 1:41-64.
-
(1996)
Atlas Hand Clin
, vol.1
, pp. 41-64
-
-
Sandow, M.J.1
McMahon, M.M.2
-
26
-
-
0032745605
-
A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: A human cadaveric study
-
Grill RS, Lim BH, Shatford RA, Toth E, Voor MJ, Tsai TM. A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: a human cadaveric study. J Hand Surg 1999;24A:1315-1322.
-
(1999)
J Hand Surg
, vol.24 A
, pp. 1315-1322
-
-
Grill, R.S.1
Lim, B.H.2
Shatford, R.A.3
Toth, E.4
Voor, M.J.5
Tsai, T.M.6
|