메뉴 건너뛰기




Volumn 36, Issue 8, 2003, Pages 587-599

Explicit geometric model of a radioscopic imaging system

Author keywords

Calibration; Computer vision; Image intensifier; Radioscopy; X ray imaging system

Indexed keywords

CAMERAS; CHARGE COUPLED DEVICES; COMPUTER VISION; IMAGE INTENSIFIERS (ELECTRON TUBE); IMAGE RECONSTRUCTION; IMAGING SYSTEMS; X RAYS;

EID: 0141569652     PISSN: 09638695     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0963-8695(03)00084-7     Document Type: Article
Times cited : (28)

References (21)
  • 1
    • 0038460106 scopus 로고    scopus 로고
    • Image processing for fault detection in aluminum castings
    • D.S. MacKenzie, & G. Totten. New York: Marcel Dekker. in press
    • Mery D., Filbert D., Jaeger T. Image processing for fault detection in aluminum castings. MacKenzie D.S., Totten G. Analytical characterization of aluminum and its alloys. 2003;Marcel Dekker, New York. in press.
    • (2003) Analytical Characterization of Aluminum and Its Alloys
    • Mery, D.1    Filbert, D.2    Jaeger, T.3
  • 4
    • 0030086342 scopus 로고    scopus 로고
    • A new stereoscopic X-ray imaging technique using a single X-ray source: Theoretical analysis
    • Evans J.P., Robinson M., Godber S.X. A new stereoscopic X-ray imaging technique using a single X-ray source: theoretical analysis. NDT&E Int. 29:(1):1996;27-35.
    • (1996) NDT&E Int , vol.29 , Issue.1 , pp. 27-35
    • Evans, J.P.1    Robinson, M.2    Godber, S.X.3
  • 5
    • 0036969319 scopus 로고    scopus 로고
    • Automated flaw detection in aluminum castings based on the tracking of potential defects in a radioscopic image sequence
    • December
    • Mery D., Filbert D. Automated flaw detection in aluminum castings based on the tracking of potential defects in a radioscopic image sequence. IEEE Trans Robotics Autom. 18:(6):December 2002;890-901.
    • (2002) IEEE Trans Robotics Autom , vol.18 , Issue.6 , pp. 890-901
    • Mery, D.1    Filbert, D.2
  • 6
    • 0023397578 scopus 로고
    • A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
    • Tsai R. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE Trans Robotics Autom. RA-3:(4):1987;323-344.
    • (1987) IEEE Trans Robotics Autom , vol.RA-3 , Issue.4 , pp. 323-344
    • Tsai, R.1
  • 7
    • 0028424876 scopus 로고
    • Implicit and explicit camera calibration: Theory and experiments
    • Wei G.-Q., Ma S.D. Implicit and explicit camera calibration: theory and experiments. IEEE Trans Pattern Anal Machine Intell. 16:(5):1994;469-480.
    • (1994) IEEE Trans Pattern Anal Machine Intell , vol.16 , Issue.5 , pp. 469-480
    • Wei, G.-Q.1    Ma, S.D.2
  • 9
    • 0026940279 scopus 로고
    • Camera calibration with distorsion models and accuracy evaluation
    • Weng J., Cohen P., Herniou M. Camera calibration with distorsion models and accuracy evaluation. IEEE Trans Pattern Anal Machine Intell. 4:(10):1992;965-980.
    • (1992) IEEE Trans Pattern Anal Machine Intell , vol.4 , Issue.10 , pp. 965-980
    • Weng, J.1    Cohen, P.2    Herniou, M.3
  • 10
    • 0000879124 scopus 로고    scopus 로고
    • A flexible new technique for camera calibration
    • Zhang Z. A flexible new technique for camera calibration. IEEE Trans Pattern Anal Machine Intell. 22:(11):2000;1330-1334.
    • (2000) IEEE Trans Pattern Anal Machine Intell , vol.22 , Issue.11 , pp. 1330-1334
    • Zhang, Z.1
  • 11
    • 0031099678 scopus 로고    scopus 로고
    • Self calibration of a moving camera from point correspondences and fundamental matrices
    • Luong Q.-T., Faugeras O. Self calibration of a moving camera from point correspondences and fundamental matrices. Int J Comput Vis. 22:(3):1997;261-289.
    • (1997) Int J Comput Vis , vol.22 , Issue.3 , pp. 261-289
    • Luong, Q.-T.1    Faugeras, O.2
  • 13
    • 0034291373 scopus 로고    scopus 로고
    • Geometric camera calibration using circular control points
    • Heikkilä J. Geometric camera calibration using circular control points. IEEE Trans Pattern Anal Machine Intell. 22:(10):2000;1066-1077.
    • (2000) IEEE Trans Pattern Anal Machine Intell , vol.22 , Issue.10 , pp. 1066-1077
    • Heikkilä, J.1
  • 14
    • 0034291838 scopus 로고    scopus 로고
    • Nonmetric calibration of wide-angle lenses and polycameras
    • Swaminathan R., Nayar S.K. Nonmetric calibration of wide-angle lenses and polycameras. IEEE Trans Pattern Anal Machine Inell. 22:(10):2000;1172-1178.
    • (2000) IEEE Trans Pattern Anal Machine Inell , vol.22 , Issue.10 , pp. 1172-1178
    • Swaminathan, R.1    Nayar, S.K.2
  • 15
    • 0141749813 scopus 로고
    • Master theses, Institute for Measurement and Automation, Faculty of Electrical Engineering, Technical University of Berlin, in German
    • Jaeger Th. Methods for rectification of geometric distortion in radioscopic images. Master theses, Institute for Measurement and Automation, Faculty of Electrical Engineering, Technical University of Berlin, 1990 (in German).
    • (1990) Methods for Rectification of Geometric Distortion in Radioscopic Images
    • Jaeger, Th.1
  • 17
    • 0001611965 scopus 로고    scopus 로고
    • The epipolar geometry in the radioscopy: Theory and application
    • in German
    • Mery D., Filbert D. The epipolar geometry in the radioscopy: theory and application. at - Automatisierungstechnik. 48:(12):2000;588-596. in German.
    • (2000) At - Automatisierungstechnik , vol.48 , Issue.12 , pp. 588-596
    • Mery, D.1    Filbert, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.