메뉴 건너뛰기




Volumn 29, Issue 9, 2003, Pages 1761-1766

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AMETROPIA; ANALYTIC METHOD; ANISOMETROPIA; ARTICLE; ARTISAN TORIC PHAKIC INTRAOCULAR LENS IMPLANTATION; ASTIGMATISM; CLINICAL ARTICLE; DOUBLED ANGLE SCATTERPLOT ANALYSIS; EMMETROPIA; EYE MOVEMENT CONTROL; FEMALE; FOLLOW UP; HUMAN; INCISION; LENS IMPLANTATION; MALE; MATHEMATICAL COMPUTING; MIOSIS; MULTIVARIATE ANALYSIS; MYDRIASIS; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; REFRACTION ERROR; ROTATION; SCLERA; STATISTICAL SIGNIFICANCE; SURGICAL APPROACH; SUTURING METHOD; TREATMENT PLANNING; VISUAL ACUITY; VISUAL DISORDER;

EID: 0141532039     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0886-3350(03)00014-2     Document Type: Article
Times cited : (52)

References (19)
  • 1
    • 0037228073 scopus 로고    scopus 로고
    • Toric phakic intraocular lens: European multicenter study
    • Dick HB, Alió J, Bianchetti M, et al. Toric phakic intraocular lens: European multicenter study. Ophthalmology 2003; 110:150-162
    • (2003) Ophthalmology , vol.110 , pp. 150-162
    • Dick, H.B.1    Alió, J.2    Bianchetti, M.3
  • 2
    • 0033805132 scopus 로고    scopus 로고
    • Multicenter study of the Artisan phakic intraocular lens
    • Budo C, Hessloehl JC, Izak M, et al. Multicenter study of the Artisan phakic intraocular lens. J Cataract Refract Surg 2000; 26:1163-1171
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1163-1171
    • Budo, C.1    Hessloehl, J.C.2    Izak, M.3
  • 3
    • 0001407285 scopus 로고
    • The pathophysiology of corneal astigmatism after cataract extraction
    • Jaffe NS, Clayman HM. The pathophysiology of corneal astigmatism after cataract extraction. Trans Am Acad Ophthalmol Otolaryngol 1975; 79:OP615-OP630
    • (1975) Trans Am Acad Ophthalmol Otolaryngol , vol.79
    • Jaffe, N.S.1    Clayman, H.M.2
  • 4
    • 0035142284 scopus 로고    scopus 로고
    • Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism
    • Holladay JT, Moran JR, Kezirian GM. Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism. J Cataract Refract Surg 2001; 27:61-79
    • (2001) J Cataract Refract Surg , vol.27 , pp. 61-79
    • Holladay, J.T.1    Moran, J.R.2    Kezirian, G.M.3
  • 5
    • 0035146835 scopus 로고    scopus 로고
    • Multivariate analysis of refractive data; mathematics and statistics of spherocylinders
    • Naeser K, Hjortdal J. Multivariate analysis of refractive data; mathematics and statistics of spherocylinders. J Cataract Refract Surg 2001; 27:129-142
    • (2001) J Cataract Refract Surg , vol.27 , pp. 129-142
    • Naeser, K.1    Hjortdal, J.2
  • 7
    • 0001038967 scopus 로고
    • The generalisation of student's ratio
    • Hotelling H. The generalisation of student's ratio. Ann Math Stat 1931; 2:360-378
    • (1931) Ann Math Stat , vol.2 , pp. 360-378
    • Hotelling, H.1
  • 8
    • 0034854580 scopus 로고    scopus 로고
    • Torische intraokularlinsen; klinische ergebnisse und rotationsstabilität
    • Gerten G, Michels A, Olmes A. Torische Intraokularlinsen; Klinische Ergebnisse und Rotationsstabilität. Ophthalmologe 2001; 98:715-720
    • (2001) Ophthalmologe , vol.98 , pp. 715-720
    • Gerten, G.1    Michels, A.2    Olmes, A.3
  • 9
    • 0033861317 scopus 로고    scopus 로고
    • Astigmatism correction with a foldable toric intraocular lens in cataract patients
    • Ruhswurm I, Scholz U, Zehetmayer M, et al. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg 2000; 26:1022-1027
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1022-1027
    • Ruhswurm, I.1    Scholz, U.2    Zehetmayer, M.3
  • 10
    • 0027931675 scopus 로고
    • Toric intraocular lenses: Correcting astigmatism while controlling axis shift
    • Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling axis shift. J Cataract Refract Surg 1994; 20:523-526
    • (1994) J Cataract Refract Surg , vol.20 , pp. 523-526
    • Shimizu, K.1    Misawa, A.2    Suzuki, Y.3
  • 11
    • 0033766516 scopus 로고    scopus 로고
    • Toric intraocular lenses for correcting astigmatism in 130 eyes
    • discussion by RM Kershner, 1781-1782
    • Sun X-Y, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology 2000; 107:1776-1781; discussion by RM Kershner, 1781-1782
    • (2000) Ophthalmology , vol.107 , pp. 1776-1781
    • Sun, X.-Y.1    Vicary, D.2    Montgomery, P.3    Griffiths, M.4
  • 12
    • 0033504828 scopus 로고    scopus 로고
    • Postoperative intraocular lens rotation; a randomized comparison of plate and loop haptic implants
    • discussion by DJ Apple, 2196
    • Patel CK, Ormonde S, Rosen P, Bron AJ. Postoperative intraocular lens rotation; a randomized comparison of plate and loop haptic implants. Ophthalmology 1999; 106:2190-2195; discussion by DJ Apple, 2196
    • (1999) Ophthalmology , vol.106 , pp. 2190-2195
    • Patel, C.K.1    Ormonde, S.2    Rosen, P.3    Bron, A.J.4
  • 13
    • 0035028345 scopus 로고    scopus 로고
    • Prospective evaluation of a plate haptic toric intraocular lens
    • Leyland M, Zinicola E, Bloom P, Lee N. Prospective evaluation of a plate haptic toric intraocular lens. Eye 2001; 15:202-205
    • (2001) Eye , vol.15 , pp. 202-205
    • Leyland, M.1    Zinicola, E.2    Bloom, P.3    Lee, N.4
  • 14
    • 0035145990 scopus 로고    scopus 로고
    • How should we analyze astigmatic data?
    • Koch DD. How should we analyze astigmatic data? [editorial] J Cataract Refract Surg 2001; 27:1-3
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1-3
    • Koch, D.D.1
  • 15
    • 0035010599 scopus 로고    scopus 로고
    • Measuring patient outcomes after refractive surgery
    • Koch DD. Measuring patient outcomes after refractive surgery [editorial]. J Cataract Refract Surg 2001; 27:645-646
    • (2001) J Cataract Refract Surg , vol.27 , pp. 645-646
    • Koch, D.D.1
  • 16
    • 0035152760 scopus 로고    scopus 로고
    • Popperian falsification of methods of assessing surgically induced astigmatism
    • Naeser K. Popperian falsification of methods of assessing surgically induced astigmatism. J Cataract Refract Surg 2001; 27:25-30
    • (2001) J Cataract Refract Surg , vol.27 , pp. 25-30
    • Naeser, K.1
  • 17
    • 0028288145 scopus 로고
    • Quantitative assessment of corneal astigmatic surgery: Expanding the polar values concept
    • Naeser K, Behrens JK, Naeser EV. Quantitative assessment of corneal astigmatic surgery: expanding the polar values concept. J Cataract Refract Surg 1994; 20:162-168
    • (1994) J Cataract Refract Surg , vol.20 , pp. 162-168
    • Naeser, K.1    Behrens, J.K.2    Naeser, E.V.3
  • 18
    • 0032471241 scopus 로고    scopus 로고
    • Comparison of surgically induced astigmatism after sutureless temporal clear corneal and scleral frown incisions
    • Huang F-C, Tseng S-H. Comparison of surgically induced astigmatism after sutureless temporal clear corneal and scleral frown incisions. J Cataract Refract Surg 1998; 24:477-481
    • (1998) J Cataract Refract Surg , vol.24 , pp. 477-481
    • Huang, F.-C.1    Tseng, S.-H.2
  • 19
    • 0030475839 scopus 로고    scopus 로고
    • Astigmatism after phacoemulsification with adjusted and unadjusted sutured versus sutureless 5.2 mm superior scleral incisions
    • Lyhne N, Corydon L. Astigmatism after phacoemulsification with adjusted and unadjusted sutured versus sutureless 5.2 mm superior scleral incisions. J Cataract Refract Surg 1996; 22:1206-1210
    • (1996) J Cataract Refract Surg , vol.22 , pp. 1206-1210
    • Lyhne, N.1    Corydon, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.