The use of magnesium silicate (talc) in a potentiometric sensor for hydrogen ions

Author keywords

Graphite epoxy electrode; Magnesium silicate; PH sensor; Potentiometric titrations; Talc

Indexed keywords

EPOXY RESINS; HYDROGEN; PH SENSORS; POTENTIOMETRIC SENSORS;

EID: 0141521522     PISSN: 01691317     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0169-1317(03)00131-5     Document Type: Article
Times cited : (8)

References (16)
  • 1
    • 0032023407 scopus 로고    scopus 로고
    • Electrodes coated by hydrotalcite-like clays. Effect of the metals and the intercalated anions on ion accumulation and retention capability
    • Ballarin B. Gazzano M. Seeber R. Tonelli D. Vaccari A. Electrodes coated by hydrotalcite-like clays. Effect of the metals and the intercalated anions on ion accumulation and retention capability J. Electroanal. Chem. 445 1998 27-37
    • (1998) J. Electroanal. Chem. , vol.445 , pp. 27-37
    • Ballarin, B.1    Gazzano, M.2    Seeber, R.3    Tonelli, D.4    Vaccari, A.5
  • 2
    • 0002430856 scopus 로고
    • Electrodes modified with clays, zeolites and related microporous solids
    • R. W. Murray New York: Wiley Techniques of Chemistry Series
    • Bard A.J. Mallouk T. Electrodes modified with clays, zeolites and related microporous solids Murray R.W. Molecular Design of Electrodes Surfaces Techniques of Chemistry Series vol. XXII 1990 217-312 Wiley New York
    • (1990) Molecular Design of Electrodes Surfaces , vol.22 , pp. 217-312
    • Bard, A.J.1    Mallouk, T.2
  • 3
    • 0345580266 scopus 로고    scopus 로고
    • Electrocatalytic reduction of molecular oxygen on a sodium montmorillonite-methyl viologen carbon paste chemically modified electrode
    • Hu S.S. Electrocatalytic reduction of molecular oxygen on a sodium montmorillonite-methyl viologen carbon paste chemically modified electrode J. Electroanal. Chem. 463 1999 253-257
    • (1999) J. Electroanal. Chem. , vol.463 , pp. 253-257
    • Hu, S.S.1
  • 5
    • 0034583224 scopus 로고    scopus 로고
    • IUPACRecommendations
    • IUPAC Recommendations Pure Appl. Chem. 72 2000 1851-2082
    • (2000) Pure Appl. Chem. , vol.72 , pp. 1851-2082
  • 6
    • 0002116292 scopus 로고    scopus 로고
    • Sorption of organic compounds on clay minerals: A surface functional group approach
    • J. R. Walker, W. Hudnall CMS Workshop Lectures Bloomington, USA: The Clay Minerals Society
    • Johnston C.T. Sorption of organic compounds on clay minerals: A surface functional group approach Walker J.R. Hudnall W. Organic Pollutants in the Environment, CMS Workshop Lectures 1996 8 The Clay Minerals Society Bloomington, USA
    • (1996) Organic Pollutants in the Environment , pp. 8
    • Johnston, C.T.1
  • 8
    • 0030364590 scopus 로고    scopus 로고
    • Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    • Kula P. Navrátilová Z. Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode Fresenius' J. Anal. Chem. 354 1996 692-695
    • (1996) Fresenius' J. Anal. Chem. , vol.354 , pp. 692-695
    • Kula, P.1    Navrátilová, Z.2
  • 10
    • 0003086209 scopus 로고
    • Smectitic clays as ionic macromolecules
    • A. D. Wilson, H. J. Prosser Amsterdan: Elsevier
    • Lagaly G. Smectitic clays as ionic macromolecules Wilson A.D. Prosser H.J. Developments In Ionic Polymers vol. 2 1986 82-84 Elsevier Amsterdan
    • (1986) Developments in Ionic Polymers , vol.2 , pp. 82-84
    • Lagaly, G.1
  • 11
    • 58149212787 scopus 로고
    • Realization of humidity sensors based on a screen-printed anionic clay
    • Moneyron J.E. de Roy A. Forano C. Besse J.P. Realization of humidity sensors based on a screen-printed anionic clay Appl. Clay Sci. 10 1995 163-175
    • (1995) Appl. Clay Sci. , vol.10 , pp. 163-175
    • Moneyron, J.E.1    de Roy, A.2    Forano, C.3    Besse, J.P.4
  • 13
    • 0001179899 scopus 로고
    • Polymer-modified electrodes through and through
    • Shaw B.R. Creasy K.E. Polymer-modified electrodes through and through J. Electroanal. Chem. 243 1988 209-217
    • (1988) J. Electroanal. Chem. , vol.243 , pp. 209-217
    • Shaw, B.R.1    Creasy, K.E.2
  • 14
    • 0002009925 scopus 로고    scopus 로고
    • Potentiometric determination of acids and bases using a silica gel based carbon-epoxy indicator electrode
    • Teixeira M.F.S. Ramos L.A. Almeida Neves E. Fatibello-Filho O. Potentiometric determination of acids and bases using a silica gel based carbon-epoxy indicator electrode Fresenius' J. Anal. Chem. 367 2000 86-89
    • (2000) Fresenius' J. Anal. Chem. , vol.367 , pp. 86-89
    • Teixeira, M.F.S.1    Ramos, L.A.2    Almeida Neves, E.3    Fatibello-Filho, O.4
  • 15
    • 0000897102 scopus 로고
    • Electrode modified with synthetic anionic clays
    • Therias S. Mousty C. Electrode modified with synthetic anionic clays Appl. Clay Sci. 10 1995 147-162
    • (1995) Appl. Clay Sci. , vol.10 , pp. 147-162
    • Therias, S.1    Mousty, C.2
  • 16
    • 37049137333 scopus 로고
    • Site-binding model of the electrical double-layer at the oxide/water interface
    • Yates D.E. Levine S. Healy T.W. Site-binding model of the electrical double-layer at the oxide/water interface J. Chem. Soc., Faraday Trans. I 70 1974 1807-1818
    • (1974) J. Chem. Soc., Faraday Trans. I , vol.70 , pp. 1807-1818
    • Yates, D.E.1    Levine, S.2    Healy, T.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.