메뉴 건너뛰기




Volumn 17, Issue 8, 2003, Pages 574-577

Distal locking of femoral nails under direct vision through a cortical window

Author keywords

Distal targeting; Femur; Fracture; Interlocking nailing

Indexed keywords

ADULT; ARTICLE; BONE SCREW; CLINICAL ARTICLE; CONTROLLED STUDY; CORTICAL BONE; FEMALE; FEMUR SHAFT FRACTURE; FRACTURE HEALING; HUMAN; IMAGE INTENSIFIER; INTRAMEDULLARY NAILING; MALE; OUTCOMES RESEARCH; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 0141507896     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-200309000-00006     Document Type: Article
Times cited : (16)

References (29)
  • 1
    • 0026578472 scopus 로고
    • Intramedullary nailing of femoral shaft fractures: III. Long term effects of static interlocking fixation
    • Brumback R, Ellison T, Poka A. Intramedullary nailing of femoral shaft fractures: III. Long term effects of static interlocking fixation. J Bone Joint Surg Am. 1992;74:106-112.
    • (1992) J. Bone Joint Surg. Am. , vol.74 , pp. 106-112
    • Brumback, R.1    Ellison, T.2    Poka, A.3
  • 2
    • 0031365203 scopus 로고    scopus 로고
    • A computer assisted orthopaedic surgical system for distal locking of intramedullary nails
    • Viant W, Phillips R, Griffiths JG, et al. A computer assisted orthopaedic surgical system for distal locking of intramedullary nails. Proc Inst Mech Eng [H]. 1997;211:293-300.
    • (1997) Proc. Inst. Mech. Eng. [H] , vol.211 , pp. 293-300
    • Viant, W.1    Phillips, R.2    Griffiths, J.G.3
  • 3
    • 0027355690 scopus 로고
    • Distal locking screw insertion using a cannulated drill bit: Technical note
    • Barrick EF. Distal locking screw insertion using a cannulated drill bit: technical note. J Orthop Trauma. 1993;7:248-251.
    • (1993) J. Orthop. Trauma. , vol.7 , pp. 248-251
    • Barrick, E.F.1
  • 4
    • 0026702109 scopus 로고
    • Interlocking intramedullary nails: An improved method of screw placement combining image intensification and laser light
    • Goulet JA, Londy F, Saltzman CL, et al. Interlocking intramedullary nails: an improved method of screw placement combining image intensification and laser light. Clin Orthop. 1992;281:199-203.
    • (1992) Clin. Orthop , vol.281 , pp. 199-203
    • Goulet, J.A.1    Londy, F.2    Saltzman, C.L.3
  • 5
    • 0031872412 scopus 로고    scopus 로고
    • A new technique of distal screw insertion for locked nailing
    • Granhed H. A new technique of distal screw insertion for locked nailing. Acta Orthop Scand. 1998;69:320-321.
    • (1998) Acta Orthop. Scand. , vol.69 , pp. 320-321
    • Granhed, H.1
  • 6
    • 0029315373 scopus 로고
    • A simple technique for insertion of distal screws into interlocking nails
    • Kelley SS, Bonar S, Hussamy OD, et al. A simple technique for insertion of distal screws into interlocking nails. J Orthop Trauma. 1995;9:227-230.
    • (1995) J. Orthop. Trauma. , vol.9 , pp. 227-230
    • Kelley, S.S.1    Bonar, S.2    Hussamy, O.D.3
  • 7
    • 0032134749 scopus 로고    scopus 로고
    • Experimental study of distal interlocking of a solid tibial nail: Radiation-independent distal aiming device (DAD) versus freehand technique (FHT)
    • Krettek C, Konemann B, Farouk O, et al. Experimental study of distal interlocking of a solid tibial nail: radiation-independent distal aiming device (DAD) versus freehand technique (FHT). J Orthop Trauma. 1998; 12:373-378.
    • (1998) J. Orthop. Trauma. , vol.12 , pp. 373-378
    • Krettek, C.1    Konemann, B.2    Farouk, O.3
  • 8
    • 0345552149 scopus 로고    scopus 로고
    • A mechanical distal aiming device for distal locking in femoral nails
    • Krettek C, Konemann B, Miclau T, et al. A mechanical distal aiming device for distal locking in femoral nails. Clin Orthop. 1999;364:267-275.
    • (1999) Clin. Orthop. , vol.364 , pp. 267-275
    • Krettek, C.1    Konemann, B.2    Miclau, T.3
  • 9
    • 0023840033 scopus 로고
    • A simplified technique of distal femoral screw insertion for the Grosse-Kempf interlocking nail
    • MacMillan M, Gross RH. A simplified technique of distal femoral screw insertion for the Grosse-Kempf interlocking nail. Clin Orthop. 1988;226: 252-259.
    • (1988) Clin. Orthop. , vol.226 , pp. 252-259
    • MacMillan, M.1    Gross, R.H.2
  • 10
    • 0031136974 scopus 로고    scopus 로고
    • Stereo fluoroscopy-assisted distal interlocking of intramedullary nails
    • Ohe T, Nakamura K, Matsushita T, et al. Stereo fluoroscopy-assisted distal interlocking of intramedullary nails. J Orthop Trauma. 1997;11:300-303.
    • (1997) J. Orthop. Trauma. , vol.11 , pp. 300-303
    • Ohe, T.1    Nakamura, K.2    Matsushita, T.3
  • 11
    • 0030857967 scopus 로고    scopus 로고
    • Intramedullary locked nailing of femur and tibia: Insertion of distal locking screws without image intensifier
    • Pennig D, Oppenheim W, Faccioli G, et al. Intramedullary locked nailing of femur and tibia: insertion of distal locking screws without image intensifier. Injury. 1997;28:323-326.
    • (1997) Injury , vol.28 , pp. 323-326
    • Pennig, D.1    Oppenheim, W.2    Faccioli, G.3
  • 12
    • 0024597239 scopus 로고
    • Distal screw targeting of interlocking nails
    • Rao JP, Allegra MP, Benevenia J, et al. Distal screw targeting of interlocking nails. Clin Orthop. 1989;238:245-248.
    • (1989) Clin. Orthop. , vol.238 , pp. 245-248
    • Rao, J.P.1    Allegra, M.P.2    Benevenia, J.3
  • 13
    • 0035257635 scopus 로고    scopus 로고
    • Novel computer-assisted fluoroscopy system for intraoperative guidance: Feasibility study for distal locking of femoral nails
    • Slomczykowski MA, Hofstetter R, Sati M, et al. Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J Orthop Trauma. 2001;15:122-131.
    • (2001) J. Orthop. Trauma. , vol.15 , pp. 122-131
    • Slomczykowski, M.A.1    Hofstetter, R.2    Sati, M.3
  • 14
    • 0030043259 scopus 로고    scopus 로고
    • Ten principles and Ten Commandments of radiation protection
    • Strom D. Ten principles and Ten Commandments of radiation protection. Health Phys. 1996;70:388-393.
    • (1996) Health Phys. , vol.70 , pp. 388-393
    • Strom, D.1
  • 15
    • 0026605655 scopus 로고
    • Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures
    • Coetzee JC, van der Merwe EJ. Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures. S Afr Med J. 1992;81:312-314.
    • (1992) S. Afr. Med. J. , vol.81 , pp. 312-314
    • Coetzee, J.C.1    van der Merwe, E.J.2
  • 16
    • 0032127740 scopus 로고    scopus 로고
    • Ionizing radiation during internal fixation of extracapsular neck of femur fractures
    • Giannoudis PV, McGuigan J, Shaw DL. Ionizing radiation during internal fixation of extracapsular neck of femur fractures. Injury. 1998;29:469-472.
    • (1998) Injury , vol.29 , pp. 469-472
    • Giannoudis, P.V.1    McGuigan, J.2    Shaw, D.L.3
  • 17
    • 0027369899 scopus 로고
    • Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic x-ray control
    • Goldstone KE, Wright IH, Cohen B. Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic x-ray control. Br J Radiol. 1993;66:899-901.
    • (1993) Br. J. Radiol. , vol.66 , pp. 899-901
    • Goldstone, K.E.1    Wright, I.H.2    Cohen, B.3
  • 18
    • 0343674725 scopus 로고    scopus 로고
    • The effects, risks, and guidelines for radiation use in orthopaedic surgery
    • Herscovici D Jr, Sanders RW. The effects, risks, and guidelines for radiation use in orthopaedic surgery. Clin Orthop. 2000;375:126-132.
    • (2000) Clin. Orthop. , vol.375 , pp. 126-132
    • Herscovici D., Jr.1    Sanders, R.W.2
  • 19
    • 0023278854 scopus 로고
    • Radiation exposure to the surgeon during closed interlocking intramedullary nailing
    • Levin PE, Schoen RW Jr, Browner BD. Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg Am. 1987;69:761-766.
    • (1987) J. Bone Joint Surg. Am. , vol.69 , pp. 761-766
    • Levin, P.E.1    Schoen R.W., Jr.2    Browner, B.D.3
  • 20
    • 0032127086 scopus 로고    scopus 로고
    • Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing
    • Muller LP, Suffner J, Wenda K, et al. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury. 1998;29: 461-468.
    • (1998) Injury , vol.29 , pp. 461-468
    • Muller, L.P.1    Suffner, J.2    Wenda, K.3
  • 21
    • 0023222981 scopus 로고
    • Interlocking medullary nails: Radiation doses in distal targeting
    • Skjeldal S, Backe S. Interlocking medullary nails: radiation doses in distal targeting. Arch Orthop Trauma Surg. 1987;106:179-181.
    • (1987) Arch. Orthop. Trauma. Surg. , vol.106 , pp. 179-181
    • Skjeldal, S.1    Backe, S.2
  • 22
    • 0033066571 scopus 로고    scopus 로고
    • Reamed intramedullary nailing of the femur: 551 cases
    • Wolinsky P, McCarty E, Shyr Y, et al. Reamed intramedullary nailing of the femur: 551 cases. J Trauma. 1999;46:392-399.
    • (1999) J. Trauma. , vol.46 , pp. 392-399
    • Wolinsky, P.1    McCarty, E.2    Shyr, Y.3
  • 23
    • 0034805228 scopus 로고    scopus 로고
    • A new distal targeting device for closed interlocking nailing
    • Tyropoulos S, Garnavos C. A new distal targeting device for closed interlocking nailing. Injury. 2001;32:732-735.
    • (2001) Injury , vol.32 , pp. 732-735
    • Tyropoulos, S.1    Garnavos, C.2
  • 24
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?"
    • Mehlman C, Di PD. Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?" J Orthop Trauma. 1997;11:392-398.
    • (1997) J. Orthop. Trauma. , vol.11 , pp. 392-398
    • Mehlman, C.1    Di, P.D.2
  • 26
    • 0030916190 scopus 로고    scopus 로고
    • Ionizing radiation: Are orthopaedic surgeon's offspring at risk?
    • Zadeh HG, Briggs TWR. Ionizing radiation: are orthopaedic surgeon's offspring at risk? Ann R Coll Engl. 1997;79:214-220.
    • (1997) Ann. R. Coll. Engl. , vol.79 , pp. 214-220
    • Zadeh, H.G.1    Briggs, T.W.R.2
  • 27
    • 0025930020 scopus 로고
    • Recommendations of the International Commission on Radiological Protection
    • IRCP
    • IRCP. Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1990;21:1-3.
    • (1990) Ann. ICRP , vol.21 , pp. 1-3
  • 28
    • 0025612507 scopus 로고
    • Shielding of the patient's gonads during intramedullary interlocking femoral nailing
    • Kwong LM, Johanson PH, Zinar DM, et al. Shielding of the patient's gonads during intramedullary interlocking femoral nailing. J Bone Joint Surg Am. 1990;72:1523-1526.
    • (1990) J. Bone Joint Surg. Am. , vol.72 , pp. 1523-1526
    • Kwong, L.M.1    Johanson, P.H.2    Zinar, D.M.3
  • 29
    • 0024734976 scopus 로고
    • How significant are the risks from occupational exposure to ionizing radiation?
    • Baker DG. How significant are the risks from occupational exposure to ionizing radiation? Appl Radiol. 1989;18:19-21.
    • (1989) Appl. Radiol. , vol.18 , pp. 19-21
    • Baker, D.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.