-
1
-
-
0026578472
-
Intramedullary nailing of femoral shaft fractures: III. Long term effects of static interlocking fixation
-
Brumback R, Ellison T, Poka A. Intramedullary nailing of femoral shaft fractures: III. Long term effects of static interlocking fixation. J Bone Joint Surg Am. 1992;74:106-112.
-
(1992)
J. Bone Joint Surg. Am.
, vol.74
, pp. 106-112
-
-
Brumback, R.1
Ellison, T.2
Poka, A.3
-
2
-
-
0031365203
-
A computer assisted orthopaedic surgical system for distal locking of intramedullary nails
-
Viant W, Phillips R, Griffiths JG, et al. A computer assisted orthopaedic surgical system for distal locking of intramedullary nails. Proc Inst Mech Eng [H]. 1997;211:293-300.
-
(1997)
Proc. Inst. Mech. Eng. [H]
, vol.211
, pp. 293-300
-
-
Viant, W.1
Phillips, R.2
Griffiths, J.G.3
-
3
-
-
0027355690
-
Distal locking screw insertion using a cannulated drill bit: Technical note
-
Barrick EF. Distal locking screw insertion using a cannulated drill bit: technical note. J Orthop Trauma. 1993;7:248-251.
-
(1993)
J. Orthop. Trauma.
, vol.7
, pp. 248-251
-
-
Barrick, E.F.1
-
4
-
-
0026702109
-
Interlocking intramedullary nails: An improved method of screw placement combining image intensification and laser light
-
Goulet JA, Londy F, Saltzman CL, et al. Interlocking intramedullary nails: an improved method of screw placement combining image intensification and laser light. Clin Orthop. 1992;281:199-203.
-
(1992)
Clin. Orthop
, vol.281
, pp. 199-203
-
-
Goulet, J.A.1
Londy, F.2
Saltzman, C.L.3
-
5
-
-
0031872412
-
A new technique of distal screw insertion for locked nailing
-
Granhed H. A new technique of distal screw insertion for locked nailing. Acta Orthop Scand. 1998;69:320-321.
-
(1998)
Acta Orthop. Scand.
, vol.69
, pp. 320-321
-
-
Granhed, H.1
-
6
-
-
0029315373
-
A simple technique for insertion of distal screws into interlocking nails
-
Kelley SS, Bonar S, Hussamy OD, et al. A simple technique for insertion of distal screws into interlocking nails. J Orthop Trauma. 1995;9:227-230.
-
(1995)
J. Orthop. Trauma.
, vol.9
, pp. 227-230
-
-
Kelley, S.S.1
Bonar, S.2
Hussamy, O.D.3
-
7
-
-
0032134749
-
Experimental study of distal interlocking of a solid tibial nail: Radiation-independent distal aiming device (DAD) versus freehand technique (FHT)
-
Krettek C, Konemann B, Farouk O, et al. Experimental study of distal interlocking of a solid tibial nail: radiation-independent distal aiming device (DAD) versus freehand technique (FHT). J Orthop Trauma. 1998; 12:373-378.
-
(1998)
J. Orthop. Trauma.
, vol.12
, pp. 373-378
-
-
Krettek, C.1
Konemann, B.2
Farouk, O.3
-
8
-
-
0345552149
-
A mechanical distal aiming device for distal locking in femoral nails
-
Krettek C, Konemann B, Miclau T, et al. A mechanical distal aiming device for distal locking in femoral nails. Clin Orthop. 1999;364:267-275.
-
(1999)
Clin. Orthop.
, vol.364
, pp. 267-275
-
-
Krettek, C.1
Konemann, B.2
Miclau, T.3
-
9
-
-
0023840033
-
A simplified technique of distal femoral screw insertion for the Grosse-Kempf interlocking nail
-
MacMillan M, Gross RH. A simplified technique of distal femoral screw insertion for the Grosse-Kempf interlocking nail. Clin Orthop. 1988;226: 252-259.
-
(1988)
Clin. Orthop.
, vol.226
, pp. 252-259
-
-
MacMillan, M.1
Gross, R.H.2
-
10
-
-
0031136974
-
Stereo fluoroscopy-assisted distal interlocking of intramedullary nails
-
Ohe T, Nakamura K, Matsushita T, et al. Stereo fluoroscopy-assisted distal interlocking of intramedullary nails. J Orthop Trauma. 1997;11:300-303.
-
(1997)
J. Orthop. Trauma.
, vol.11
, pp. 300-303
-
-
Ohe, T.1
Nakamura, K.2
Matsushita, T.3
-
11
-
-
0030857967
-
Intramedullary locked nailing of femur and tibia: Insertion of distal locking screws without image intensifier
-
Pennig D, Oppenheim W, Faccioli G, et al. Intramedullary locked nailing of femur and tibia: insertion of distal locking screws without image intensifier. Injury. 1997;28:323-326.
-
(1997)
Injury
, vol.28
, pp. 323-326
-
-
Pennig, D.1
Oppenheim, W.2
Faccioli, G.3
-
12
-
-
0024597239
-
Distal screw targeting of interlocking nails
-
Rao JP, Allegra MP, Benevenia J, et al. Distal screw targeting of interlocking nails. Clin Orthop. 1989;238:245-248.
-
(1989)
Clin. Orthop.
, vol.238
, pp. 245-248
-
-
Rao, J.P.1
Allegra, M.P.2
Benevenia, J.3
-
13
-
-
0035257635
-
Novel computer-assisted fluoroscopy system for intraoperative guidance: Feasibility study for distal locking of femoral nails
-
Slomczykowski MA, Hofstetter R, Sati M, et al. Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J Orthop Trauma. 2001;15:122-131.
-
(2001)
J. Orthop. Trauma.
, vol.15
, pp. 122-131
-
-
Slomczykowski, M.A.1
Hofstetter, R.2
Sati, M.3
-
14
-
-
0030043259
-
Ten principles and Ten Commandments of radiation protection
-
Strom D. Ten principles and Ten Commandments of radiation protection. Health Phys. 1996;70:388-393.
-
(1996)
Health Phys.
, vol.70
, pp. 388-393
-
-
Strom, D.1
-
15
-
-
0026605655
-
Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures
-
Coetzee JC, van der Merwe EJ. Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures. S Afr Med J. 1992;81:312-314.
-
(1992)
S. Afr. Med. J.
, vol.81
, pp. 312-314
-
-
Coetzee, J.C.1
van der Merwe, E.J.2
-
16
-
-
0032127740
-
Ionizing radiation during internal fixation of extracapsular neck of femur fractures
-
Giannoudis PV, McGuigan J, Shaw DL. Ionizing radiation during internal fixation of extracapsular neck of femur fractures. Injury. 1998;29:469-472.
-
(1998)
Injury
, vol.29
, pp. 469-472
-
-
Giannoudis, P.V.1
McGuigan, J.2
Shaw, D.L.3
-
17
-
-
0027369899
-
Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic x-ray control
-
Goldstone KE, Wright IH, Cohen B. Radiation exposure to the hands of orthopaedic surgeons during procedures under fluoroscopic x-ray control. Br J Radiol. 1993;66:899-901.
-
(1993)
Br. J. Radiol.
, vol.66
, pp. 899-901
-
-
Goldstone, K.E.1
Wright, I.H.2
Cohen, B.3
-
18
-
-
0343674725
-
The effects, risks, and guidelines for radiation use in orthopaedic surgery
-
Herscovici D Jr, Sanders RW. The effects, risks, and guidelines for radiation use in orthopaedic surgery. Clin Orthop. 2000;375:126-132.
-
(2000)
Clin. Orthop.
, vol.375
, pp. 126-132
-
-
Herscovici D., Jr.1
Sanders, R.W.2
-
19
-
-
0023278854
-
Radiation exposure to the surgeon during closed interlocking intramedullary nailing
-
Levin PE, Schoen RW Jr, Browner BD. Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg Am. 1987;69:761-766.
-
(1987)
J. Bone Joint Surg. Am.
, vol.69
, pp. 761-766
-
-
Levin, P.E.1
Schoen R.W., Jr.2
Browner, B.D.3
-
20
-
-
0032127086
-
Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing
-
Muller LP, Suffner J, Wenda K, et al. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury. 1998;29: 461-468.
-
(1998)
Injury
, vol.29
, pp. 461-468
-
-
Muller, L.P.1
Suffner, J.2
Wenda, K.3
-
21
-
-
0023222981
-
Interlocking medullary nails: Radiation doses in distal targeting
-
Skjeldal S, Backe S. Interlocking medullary nails: radiation doses in distal targeting. Arch Orthop Trauma Surg. 1987;106:179-181.
-
(1987)
Arch. Orthop. Trauma. Surg.
, vol.106
, pp. 179-181
-
-
Skjeldal, S.1
Backe, S.2
-
22
-
-
0033066571
-
Reamed intramedullary nailing of the femur: 551 cases
-
Wolinsky P, McCarty E, Shyr Y, et al. Reamed intramedullary nailing of the femur: 551 cases. J Trauma. 1999;46:392-399.
-
(1999)
J. Trauma.
, vol.46
, pp. 392-399
-
-
Wolinsky, P.1
McCarty, E.2
Shyr, Y.3
-
23
-
-
0034805228
-
A new distal targeting device for closed interlocking nailing
-
Tyropoulos S, Garnavos C. A new distal targeting device for closed interlocking nailing. Injury. 2001;32:732-735.
-
(2001)
Injury
, vol.32
, pp. 732-735
-
-
Tyropoulos, S.1
Garnavos, C.2
-
24
-
-
0031204509
-
Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?"
-
Mehlman C, Di PD. Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?" J Orthop Trauma. 1997;11:392-398.
-
(1997)
J. Orthop. Trauma.
, vol.11
, pp. 392-398
-
-
Mehlman, C.1
Di, P.D.2
-
26
-
-
0030916190
-
Ionizing radiation: Are orthopaedic surgeon's offspring at risk?
-
Zadeh HG, Briggs TWR. Ionizing radiation: are orthopaedic surgeon's offspring at risk? Ann R Coll Engl. 1997;79:214-220.
-
(1997)
Ann. R. Coll. Engl.
, vol.79
, pp. 214-220
-
-
Zadeh, H.G.1
Briggs, T.W.R.2
-
27
-
-
0025930020
-
Recommendations of the International Commission on Radiological Protection
-
IRCP
-
IRCP. Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1990;21:1-3.
-
(1990)
Ann. ICRP
, vol.21
, pp. 1-3
-
-
-
28
-
-
0025612507
-
Shielding of the patient's gonads during intramedullary interlocking femoral nailing
-
Kwong LM, Johanson PH, Zinar DM, et al. Shielding of the patient's gonads during intramedullary interlocking femoral nailing. J Bone Joint Surg Am. 1990;72:1523-1526.
-
(1990)
J. Bone Joint Surg. Am.
, vol.72
, pp. 1523-1526
-
-
Kwong, L.M.1
Johanson, P.H.2
Zinar, D.M.3
-
29
-
-
0024734976
-
How significant are the risks from occupational exposure to ionizing radiation?
-
Baker DG. How significant are the risks from occupational exposure to ionizing radiation? Appl Radiol. 1989;18:19-21.
-
(1989)
Appl. Radiol.
, vol.18
, pp. 19-21
-
-
Baker, D.G.1
|