메뉴 건너뛰기




Volumn 19, Issue 4, 2003, Pages 259-266

End-diastolic and end-systolic volume from the left ventricular angiogram: How accurate is visual frame selection?

Author keywords

Cardiac volume; Frame by frame analysis; LV ventriculography

Indexed keywords

ADULT; AGED; ARTICLE; CALCULATION; CLINICAL ARTICLE; CLINICAL PRACTICE; CLINICAL TRIAL; COMPARATIVE STUDY; COMPUTER ANALYSIS; COMPUTER PROGRAM; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; FRAME BY FRAME ANALYSIS; HEART CINEVENTRICULOGRAPHY; HEART CYCLE; HEART DISEASE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART LEFT VENTRICLE VOLUME; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; LABORATORY AUTOMATION; LINEAR REGRESSION ANALYSIS; MALE; MEDICAL DECISION MAKING; STATISTICAL ANALYSIS;

EID: 0141459225     PISSN: 15695794     EISSN: 18758312     Source Type: Journal    
DOI: 10.1023/A:1025406614571     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 0000713480 scopus 로고
    • The use of biplane angiocardiography for the measurement of left ventricular volume in man
    • Dodge HT, Sandler H, Balley DW, Lord JD. The use of biplane angiocardiography for the measurement of left ventricular volume in man. Am Heart J 1960; 60: 762-776.
    • (1960) Am Heart J , vol.60 , pp. 762-776
    • Dodge, H.T.1    Sandler, H.2    Balley, D.W.3    Lord, J.D.4
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 0023176402 scopus 로고
    • Comparison of monoplane and biplane assessment of regional left ventricular wall motion after thrombolytic therapy for acute myocardial infarction
    • Holmes DR Jr., Bove AA, Nishimura RA, et al. Comparison of monoplane and biplane assessment of regional left ventricular wall motion after thrombolytic therapy for acute myocardial infarction. Am J Cardiol 1987; 59(8): 793-797.
    • (1987) Am J Cardiol , vol.59 , Issue.8 , pp. 793-797
    • Holmes D.R., Jr.1    Bove, A.A.2    Nishimura, R.A.3
  • 4
    • 84886625118 scopus 로고
    • Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections
    • Wynne J, Green LH, Mann T, Levin D, Grossman W. Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections. Am J Cardiol 1978; 41(4): 726-732.
    • (1978) Am J Cardiol , vol.41 , Issue.4 , pp. 726-732
    • Wynne, J.1    Green, L.H.2    Mann, T.3    Levin, D.4    Grossman, W.5
  • 5
    • 0030038835 scopus 로고    scopus 로고
    • Accuracy and precision of angiographic volumetry methods for left and right ventricle
    • Beier J, Wellnhofer E, Oswald H, Fleck E. Accuracy and precision of angiographic volumetry methods for left and right ventricle. Int J Cardiol 1996; 53(2): 179-188.
    • (1996) Int J Cardiol , vol.53 , Issue.2 , pp. 179-188
    • Beier, J.1    Wellnhofer, E.2    Oswald, H.3    Fleck, E.4
  • 6
    • 85029993051 scopus 로고
    • Left ventricular contour detection: A fully automated approach
    • Van Der Zwet PMJ, Koning G, Reiber JH. Left ventricular contour detection: A fully automated approach. Comp Cardiol 1992; 1: 359-362.
    • (1992) Comp Cardiol , vol.1 , pp. 359-362
    • Van Der Zwet, P.M.J.1    Koning, G.2    Reiber, J.H.3
  • 7
    • 0023202215 scopus 로고
    • Sources of subjective variability in the assessment of left ventricular regional wall motion from contrast ventriculograms
    • Kussmaul WG, Kleaveland JP, Zeevi GR, Hirshfeld JW Jr. Sources of subjective variability in the assessment of left ventricular regional wall motion from contrast ventriculograms. Am J Cardiol 1987; 60(1): 153-157.
    • (1987) Am J Cardiol , vol.60 , Issue.1 , pp. 153-157
    • Kussmaul, W.G.1    Kleaveland, J.P.2    Zeevi, G.R.3    Hirshfeld J.W., Jr.4
  • 8
    • 0031922437 scopus 로고    scopus 로고
    • Normal left ventricular volumes and ejection fraction: Assessment with quantitative digital cardioangiography
    • Masquet C, Slama MS, Dibie A, Sheehan FH, Lienard J. Normal left ventricular volumes and ejection fraction: Assessment with quantitative digital cardioangiography. Int J Card Imaging 1998; 14(1): 27-36.
    • (1998) Int J Card Imaging , vol.14 , Issue.1 , pp. 27-36
    • Masquet, C.1    Slama, M.S.2    Dibie, A.3    Sheehan, F.H.4    Lienard, J.5
  • 9
    • 0029740367 scopus 로고    scopus 로고
    • Left ventricular regression equations from single plane cine and digital X-ray ventriculograms revisited
    • Reiber JH, Viddeleer AR, Koning G, Schalij MJ, Lange PE. Left ventricular regression equations from single plane cine and digital X-ray ventriculograms revisited. Int J Card Imaging 1996; 12(2): 69-78.
    • (1996) Int J Card Imaging , vol.12 , Issue.2 , pp. 69-78
    • Reiber, J.H.1    Viddeleer, A.R.2    Koning, G.3    Schalij, M.J.4    Lange, P.E.5
  • 10
    • 0019466559 scopus 로고
    • Computer enhancement of direct and venous-injected left ventricular contrast angiography
    • Vas R, Diamond GA, Forrester JS, Whiting JS, Swan HJ. Computer enhancement of direct and venous-injected left ventricular contrast angiography. Am Heart J 1981; 102(4): 719-728.
    • (1981) Am Heart J , vol.102 , Issue.4 , pp. 719-728
    • Vas, R.1    Diamond, G.A.2    Forrester, J.S.3    Whiting, J.S.4    Swan, H.J.5
  • 11
    • 0021214311 scopus 로고
    • Digital subtraction angiography in the evaluation of left ventricular function and wall motion in man
    • O'Connor MK, Quigley PJ, Gearty GF. Digital subtraction angiography in the evaluation of left ventricular function and wall motion in man. Eur Heart J 1984; 5(8): 652-659.
    • (1984) Eur Heart J , vol.5 , Issue.8 , pp. 652-659
    • O'Connor, M.K.1    Quigley, P.J.2    Gearty, G.F.3
  • 12
    • 0013930422 scopus 로고
    • Experiences with a cinefluorographic method for measuring ventricular volume
    • Chapman CB, Baker O, Mitchell JH, Collier RG. Experiences with a cinefluorographic method for measuring ventricular volume. Am J Cardiol 1966; 18(1): 25-30.
    • (1966) Am J Cardiol , vol.18 , Issue.1 , pp. 25-30
    • Chapman, C.B.1    Baker, O.2    Mitchell, J.H.3    Collier, R.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.