메뉴 건너뛰기




Volumn 36, Issue 12, 2003, Pages 2623-2638

A new PVC-membrane electrode based on a diazatetrathia (N2S 4) macrocyclic ligand for selective determination of silver ion

Author keywords

Macrocyclic membrane; PVC based membrane; Silver (I) electrode

Indexed keywords

2,3,4:10,11,12 DIPYRIDINE 3,11 DIAZA 1,5,9,13 TETRATHIACYCLOHEXADECA 2,10 DIENE; BIPYRIDINE DERIVATIVE; IONOPHORE; LIGAND; MACROCYCLIC COMPOUND; NITRATE; PHTHALIC ACID DIBUTYL ESTER; PHTHALIC ACID DIOCTYL ESTER; POLYVINYLCHLORIDE; SILVER; SOLVENT; SULFATE; TETRAPHENYLBORON; UNCLASSIFIED DRUG;

EID: 0141456440     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-120024637     Document Type: Article
Times cited : (4)

References (29)
  • 1
    • 0036173529 scopus 로고    scopus 로고
    • A new macrocyclic polystyrene based sensor for chromium(III) ions
    • Singh, A.K.; Panwar, A.; Singh, R.; Baniwal, S. A new macrocyclic polystyrene based sensor for chromium(III) ions. Anal. Bioanal. Chem. 2002, 372, 506.
    • (2002) Anal. Bioanal. Chem. , vol.372 , pp. 506
    • Singh, A.K.1    Panwar, A.2    Singh, R.3    Baniwal, S.4
  • 2
    • 0000094888 scopus 로고    scopus 로고
    • Pvc-based hexathia-18-crown-6-tetraone sensor for mercury (II) ions
    • Fakhari, A.R.; Ganjali, M.R.; Shamsipur, M. Pvc-based hexathia-18-crown-6-tetraone sensor for mercury (II) ions. Anal. Chem. 1997, 69, 3693.
    • (1997) Anal. Chem. , vol.69 , pp. 3693
    • Fakhari, A.R.1    Ganjali, M.R.2    Shamsipur, M.3
  • 3
    • 0031131389 scopus 로고    scopus 로고
    • Nickel(II)-selective sensors based on heterogeneous membranes of macrocyclic compounds
    • Jain, A.K.; Gupta, V.K.; Singh, R.D.; Khurana, U; Singh, L.P. Nickel(II)-selective sensors based on heterogeneous membranes of macrocyclic compounds. Sens. Actuators B 1997, 40, 15.
    • (1997) Sens. Actuators B , vol.40 , pp. 15
    • Jain, A.K.1    Gupta, V.K.2    Singh, R.D.3    Khurana, U.4    Singh, L.P.5
  • 4
    • 0009806962 scopus 로고    scopus 로고
    • Lead (II)-selective membrane electrodes based on 4,7,13,16-tetrathenoyl-1,10-dioxa-4,7,13,16-tetraazacyclooctadecane
    • Yang, X.; Kumar, N.; Hibberti, D.B.; Alexander, P.W. Lead (II)-selective membrane electrodes based on 4,7,13,16-tetrathenoyl-1,10-dioxa-4,7,13,16-tetraazacyclooctadecane. Electroanalysis 1998, 10, 827.
    • (1998) Electroanalysis , vol.10 , pp. 827
    • Yang, X.1    Kumar, N.2    Hibberti, D.B.3    Alexander, P.W.4
  • 5
    • 0035178807 scopus 로고    scopus 로고
    • Strontium(II)-selective electrode based on a macrocyclic ligand
    • Panwar, A.; Baniwal, S.; Singh, R.; Sharma, C.L.; Singh, A.K. Strontium(II)-selective electrode based on a macrocyclic ligand. Anal. Lett. 2001, 34, 2415.
    • (2001) Anal. Lett. , vol.34 , pp. 2415
    • Panwar, A.1    Baniwal, S.2    Singh, R.3    Sharma, C.L.4    Singh, A.K.5
  • 6
    • 37049082025 scopus 로고
    • Mercury(II) and silver(I) ion-selective electrodes based on dithia crown ethers
    • Lai, M.-T.; Shih, J-S. Mercury(II) and silver(I) ion-selective electrodes based on dithia crown ethers. Analyst 1986, 111, 891.
    • (1986) Analyst , vol.111 , pp. 891
    • Lai, M.-T.1    Shih, J.-S.2
  • 7
    • 0001994818 scopus 로고
    • Selective membrane electrodes using acyclic dithia benzene derivatives neutral carriers. Comparison with related macrocyclic compound
    • Casabo, J.; Mestres, L.; Escricha, L.; Teixidor, F.; Perez-Jimenez, C. Selective membrane electrodes using acyclic dithia benzene derivatives neutral carriers. Comparison with related macrocyclic compound. J. Chem. Soc., Dalton Trans. 1991, 1969.
    • (1991) J. Chem. Soc., Dalton Trans. , pp. 1969
    • Casabo, J.1    Mestres, L.2    Escricha, L.3    Teixidor, F.4    Perez-Jimenez, C.5
  • 8
    • 0028032545 scopus 로고
    • Silver selective electrodes based on thioether functionalized calix[4]arenes as ionophores
    • Malinowska, E.; Brzozka, Z.; Kasiura, K.; Egberink, R.J.M.; Reinhoudt, D.N. Silver selective electrodes based on thioether functionalized calix[4]arenes as ionophores. Anal. Chim. Acta 1994, 298, 245.
    • (1994) Anal. Chim. Acta , vol.298 , pp. 245
    • Malinowska, E.1    Brzozka, Z.2    Kasiura, K.3    Egberink, R.J.M.4    Reinhoudt, D.N.5
  • 9
    • 1542582866 scopus 로고
    • Thermodynamic and kinetic data for macrocycle interaction with cations and anions
    • Izatt, R.M.; Pawlak, K.; Bradshaw, J.S.; Bruening, R.L. Thermodynamic and kinetic data for macrocycle interaction with cations and anions. Chem. Rev. 1991, 91, 1721.
    • (1991) Chem. Rev. , vol.91 , pp. 1721
    • Izatt, R.M.1    Pawlak, K.2    Bradshaw, J.S.3    Bruening, R.L.4
  • 10
    • 0031916873 scopus 로고    scopus 로고
    • Silver(I)-selective membrane electrodes based on mono- to quadridentate podands
    • Lee, S.S.; Alm, M.-K.; Park, S.B. Silver(I)-selective membrane electrodes based on mono- to quadridentate podands. Analyst 1998, 123, 383.
    • (1998) Analyst , vol.123 , pp. 383
    • Lee, S.S.1    Alm, M.-K.2    Park, S.B.3
  • 11
    • 0030978317 scopus 로고    scopus 로고
    • Silver (I)-selective membrane electrodes based on sulfur-containing podants
    • Chung, S.; Wantae, K.; Sung, B.P.; Dae, Y.K.; Shim, S.L. Silver (I)-selective membrane electrodes based on sulfur-containing podants. Talanta 1997, 44, 1291.
    • (1997) Talanta , vol.44 , pp. 1291
    • Chung, S.1    Wantae, K.2    Sung, B.P.3    Dae, Y.K.4    Shim, S.L.5
  • 12
    • 0034632232 scopus 로고    scopus 로고
    • Polymeric membrane silver-ion selective electrodes based on bis (dialkyldithiophosphate)
    • Liu, D.; Liu, J.; Tian, D.; Hong, W.; Zhou, X.; Yu, J.C. Polymeric membrane silver-ion selective electrodes based on bis (dialkyldithiophosphate). Anal. Chim. Acta 2000, 416, 139.
    • (2000) Anal. Chim. Acta , vol.416 , pp. 139
    • Liu, D.1    Liu, J.2    Tian, D.3    Hong, W.4    Zhou, X.5    Yu, J.C.6
  • 13
    • 0345003722 scopus 로고    scopus 로고
    • Silver(I)-selective membrane electrode based on hexathia-18-crown-6
    • Mashhadizadeh, M.H.; Shamsipur, M. Silver(I)-selective membrane electrode based on hexathia-18-crown-6. Anal. Chim. Acta 1999, 381, 111.
    • (1999) Anal. Chim. Acta , vol.381 , pp. 111
    • Mashhadizadeh, M.H.1    Shamsipur, M.2
  • 15
    • 0035967251 scopus 로고    scopus 로고
    • 2+-selective electrodes with lariat crown ethers as ionophores
    • 2+-selective electrodes with lariat crown ethers as ionophores. Anal. Chim. Acta 2001, 432, 261.
    • (2001) Anal. Chim. Acta , vol.432 , pp. 261
    • Su, C.-C.1    Chang, M.-C.2    Liu, L.K.3
  • 16
    • 0029275711 scopus 로고
    • +-selective electrodes based on lipophilic thioethers
    • +-selective electrodes based on lipophilic thioethers. Sens. Actuators B 1995, 24, 183.
    • (1995) Sens. Actuators B , vol.24 , pp. 183
    • Wroblewski, W.1    Brzozka, Z.2
  • 17
    • 0034738701 scopus 로고    scopus 로고
    • Silver(I) ion selective Pvc membrane based on bis-pyridine tetramide macrocycle
    • Mahajan, R.K.; Parkash, O. Silver(I) ion selective Pvc membrane based on bis-pyridine tetramide macrocycle. Talanta 2000, 52, 691.
    • (2000) Talanta , vol.52 , pp. 691
    • Mahajan, R.K.1    Parkash, O.2
  • 18
    • 0034686278 scopus 로고    scopus 로고
    • Improved silver ion-selective electrodes using Novel 1,3-bis(2-benzothiazolyl) thioalkoxy-p-tert-butylcalix[4]arenes
    • Zeng, X.; Weng, L.; Chen, L.; Leng, X.; Zhang, Z.; He, X. Improved silver ion-selective electrodes using Novel 1,3-bis(2-benzothiazolyl) thioalkoxy-p-tert-butylcalix[4]arenes. Tetrahedron Lett. 2000, 41, 4917.
    • (2000) Tetrahedron Lett. , vol.41 , pp. 4917
    • Zeng, X.1    Weng, L.2    Chen, L.3    Leng, X.4    Zhang, Z.5    He, X.6
  • 19
    • 0034679884 scopus 로고    scopus 로고
    • Calixarene derivative as the neutral carrier in silver ion-selective electrode and liquid membrane transport
    • Chen, L.; He, X.; Zhao, B.; Liu, Y. Calixarene derivative as the neutral carrier in silver ion-selective electrode and liquid membrane transport. Anal. Chim. Acta 2000, 417, 51.
    • (2000) Anal. Chim. Acta , vol.417 , pp. 51
    • Chen, L.1    He, X.2    Zhao, B.3    Liu, Y.4
  • 20
    • 0033801246 scopus 로고    scopus 로고
    • Calixarene derivatives as the sensory molecules for silver ion-selective electrode
    • Chen, L.; Zeng, X.; Ju, H.; He, X.; Zhang, Z. Calixarene derivatives as the sensory molecules for silver ion-selective electrode. Microchemical J. 2000, 65, 129.
    • (2000) Microchemical J. , vol.65 , pp. 129
    • Chen, L.1    Zeng, X.2    Ju, H.3    He, X.4    Zhang, Z.5
  • 21
    • 0034332646 scopus 로고    scopus 로고
    • Silver ion-selective electrodes using π-coordinate calix[4]arene derivatives as soft neutral carriers
    • Kimura, K.; Yajima, S.; Tatsumi, K.; Yokoyama, M.; Oue, M. Silver ion-selective electrodes using π-coordinate calix[4]arene derivatives as soft neutral carriers. Anal. Chem. 2000, 72, 5290.
    • (2000) Anal. Chem. , vol.72 , pp. 5290
    • Kimura, K.1    Yajima, S.2    Tatsumi, K.3    Yokoyama, M.4    Oue, M.5
  • 22
    • 0035958320 scopus 로고    scopus 로고
    • Silver ion-selective electrodes based on novel containing benzothiazolyl calix[4]arene
    • Chen, L.; Ju, H.; Zeng, X.; He, X.; Zhang, Z. Silver ion-selective electrodes based on novel containing benzothiazolyl calix[4]arene. Anal. Chim. Acta 2001, 437, 191.
    • (2001) Anal. Chim. Acta , vol.437 , pp. 191
    • Chen, L.1    Ju, H.2    Zeng, X.3    He, X.4    Zhang, Z.5
  • 23
    • 0037170951 scopus 로고    scopus 로고
    • +-selective electrode properties of benzothiazoly-thiaalkoxy functionalized calix[4]arenes: An investigation of the structure-selectivity relationship in the ionophore-based ISEs
    • +-selective electrode properties of benzothiazoly-thiaalkoxy functionalized calix[4]arenes: An investigation of the structure-selectivity relationship in the ionophore-based ISEs. Tetrahedron 2002, 58, 2642.
    • (2002) Tetrahedron , vol.58 , pp. 2642
    • Zeng, X.1    Weng, L.2    Chen, L.3    Xu, F.4    Li, Q.5    Leng, X.6    He, X.7    Zhang, Z.-Z.8
  • 24
    • 0035055006 scopus 로고    scopus 로고
    • Silver (I) ion-selective membrane based on schiff base-p-tert-butylcalix[4]arene
    • Mahajan, R.K.; Kumar, M.; Sharma, V.; Kaur, I. Silver (I) ion-selective membrane based on schiff base-p-tert-butylcalix[4]arene. Analyst 2001, 126, 505.
    • (2001) Analyst , vol.126 , pp. 505
    • Mahajan, R.K.1    Kumar, M.2    Sharma, V.3    Kaur, I.4
  • 25
    • 0034743818 scopus 로고    scopus 로고
    • The synthesis of some pyridyl functionalized calix[4]arenes as the sensor molecule for silver ion-selective electrodes
    • Zeng, X.; Weng, L.; Chen, L.; Leng, X.; Ju, H.; He, X.; Zhang, Z.-Z. The synthesis of some pyridyl functionalized calix[4]arenes as the sensor molecule for silver ion-selective electrodes. J. Chem. Soc., Perkin Trans. 2001, 2, 545.
    • (2001) J. Chem. Soc., Perkin Trans. , vol.2 , pp. 545
    • Zeng, X.1    Weng, L.2    Chen, L.3    Leng, X.4    Ju, H.5    He, X.6    Zhang, Z.-Z.7
  • 27
    • 77949909718 scopus 로고
    • Recommended procedure for calibration of ion-selective electrodes
    • Buck, R.P.; Cosofret, V.V. Recommended procedure for calibration of ion-selective electrodes. Pure Appl. Chem. 1993, 65, 1849.
    • (1993) Pure Appl. Chem. , vol.65 , pp. 1849
    • Buck, R.P.1    Cosofret, V.V.2
  • 28
    • 0019008094 scopus 로고
    • Life time of neutral carrier based ion-selective liquid-membrane electrodes
    • Oesch, U.; Simon, W. Life time of neutral carrier based ion-selective liquid-membrane electrodes. Anal. Chem. 1980, 52, 692.
    • (1980) Anal. Chem. , vol.52 , pp. 692
    • Oesch, U.1    Simon, W.2
  • 29
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrodes: Recommended methods for reporting values
    • Umezawa, Y.; Umezawa, K.; Sato, H. Selectivity coefficients for ion-selective electrodes: recommended methods for reporting values. Pure Appl. Chem. 1995, 67, 507.
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.