메뉴 건너뛰기




Volumn 124, Issue 3, 2002, Pages 300-304

Variable water flow pumping for central chilled water systems

Author keywords

[No Author keywords available]

Indexed keywords

CHILLED WATER SYSTEMS; EVAPORATIVE TEMPERATURE; PUMPING SYSTEMS;

EID: 0043255418     PISSN: 01996231     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1488667     Document Type: Article
Times cited : (10)

References (12)
  • 1
    • 0028713362 scopus 로고
    • Distributed Pumping for Chilled and Hot Water Systems
    • Rishel, J. B., 1994, "Distributed Pumping for Chilled and Hot Water Systems," ASHRAE Trans., 100, Pt. 1, pp. 1521-1527.
    • (1994) ASHRAE Trans , vol.100 , Issue.PART. 1 , pp. 1521-1527
    • Rishel, J.B.1
  • 2
    • 0035331797 scopus 로고    scopus 로고
    • Improving the Efficiency of Chilled Water Plants
    • Avery, G., 2001, "Improving the Efficiency of Chilled Water Plants," ASHRAE J., 43(5), pp. 14-18.
    • (2001) ASHRAE J , vol.43 , Issue.5 , pp. 14-18
    • Avery, G.1
  • 3
    • 0003513472 scopus 로고    scopus 로고
    • ASHRAE, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta, GA
    • ASHRAE, 2000, 2000 ASHRAE Handbook, HVAC Systems and Equipment, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta, GA.
    • (2000) 2000 ASHRAE Handbook, HVAC Systems and Equipment
  • 4
    • 0028728599 scopus 로고
    • Why Consider a primary-Secondary Hydronic Pumping System?
    • Hegberg, R. A., 1994, "Why Consider a primary-Secondary Hydronic Pumping System?" ASHRAE Trans., 100, Pt. 1, pp. 1516-1520.
    • (1994) ASHRAE Trans , vol.100 , Issue.PART. 1 , pp. 1516-1520
    • Hegberg, R.A.1
  • 5
    • 0034439125 scopus 로고    scopus 로고
    • Primary Chilled Water Loop Retrofit
    • Hyman, L. B., and Bockmiller, F. R., 2000, "Primary Chilled Water Loop Retrofit," ASHRAE J., 42(12), pp. 60-64.
    • (2000) ASHRAE J , vol.42 , Issue.12 , pp. 60-64
    • Hyman, L.B.1    Bockmiller, F.R.2
  • 6
    • 0025813840 scopus 로고
    • Design Considerations of a Central Variable Flow Chilled water Plant
    • Potratz, S. J., 1991, "Design Considerations of a Central Variable Flow Chilled water Plant," ASHRAE Trans., 97, Pt. 1, pp. 759-762.
    • (1991) ASHRAE Trans , vol.97 , Issue.PART. 1 , pp. 759-762
    • Potratz, S.J.1
  • 7
    • 33846056033 scopus 로고
    • Advantages and Disadvantages of Profit and Loss Control of the Chilled Water System of Centrifugal Chiller Plants
    • Kuala Lumpur, Malaysia, 25-28 October
    • Zhou, H., 1989, "Advantages and Disadvantages of Profit and Loss Control of the Chilled Water System of Centrifugal Chiller Plants," Proc. of Far East Conf. on Air Conditioning in Hot Climate, Kuala Lumpur, Malaysia, 25-28 October.
    • (1989) Proc. of Far East Conf. on Air Conditioning in Hot Climate
    • Zhou, H.1
  • 8
    • 0030313953 scopus 로고    scopus 로고
    • Hartman, T. B., 1996, Design Issues of variable Chilled-Water Flow Through Chillers, ASHRAE Trans., 102, Pi. 2, pp. 678-683.
    • Hartman, T. B., 1996, "Design Issues of variable Chilled-Water Flow Through Chillers," ASHRAE Trans., 102, Pi. 2, pp. 678-683.
  • 9
    • 0030315651 scopus 로고    scopus 로고
    • Effect of Variable Row on Centrifugal Chiller Performance
    • Redden, G. H., 1996, "Effect of Variable Row on Centrifugal Chiller Performance," ASHRAE Trans., 102, Pt. 2, pp. 684-687.
    • (1996) ASHRAE Trans , vol.102 , Issue.PART. 2 , pp. 684-687
    • Redden, G.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.