메뉴 건너뛰기




Volumn 14, Issue 8, 2003, Pages 1427-1436

Measurement of stress-strain and vibrational properties of tendons

Author keywords

Laser Doppler vibrometry; Tendon cross sectional area; Tendon mechanics; Tensile testing; Vibration measurement

Indexed keywords

CORRELATION METHODS; DOPPLER EFFECT; NATURAL FREQUENCIES; STRESSES; TENSILE TESTING; VELOCITY MEASUREMENT; VIBRATIONS (MECHANICAL);

EID: 0043241723     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/14/8/332     Document Type: Article
Times cited : (24)

References (22)
  • 1
    • 0018565978 scopus 로고
    • Pressure dependence of the area micrometer method in evaluation of cruciate ligament cross-section
    • Allard P, Thiry P S, Bourgault A and Drouin G 1979 Pressure dependence of the area micrometer method in evaluation of cruciate ligament cross-section J. Biomed. Eng. 1 265-7
    • (1979) J. Biomed. Eng. , vol.1 , pp. 265-267
    • Allard, P.1    Thiry, P.S.2    Bourgault, A.3    Drouin, G.4
  • 2
    • 0032801772 scopus 로고    scopus 로고
    • The tensile and stress relaxation responses of human patellar tendon varies with specimen cross-sectional area
    • Atkinson T S, Ewers B J and Haut R C 1999 The tensile and stress relaxation responses of human patellar tendon varies with specimen cross-sectional area J. Biomech. 32 907-14
    • (1999) J. Biomech. , vol.32 , pp. 907-914
    • Atkinson, T.S.1    Ewers, B.J.2    Haut, R.C.3
  • 3
    • 0031282061 scopus 로고    scopus 로고
    • A poroelastic model that predicts some phenomenological responses of ligaments and tendons
    • Atkinson T S, Haut R C and Altiero N J 1997 A poroelastic model that predicts some phenomenological responses of ligaments and tendons J. Biomech. Eng. 119 400-5
    • (1997) J. Biomech. Eng. , vol.119 , pp. 400-405
    • Atkinson, T.S.1    Haut, R.C.2    Altiero, N.J.3
  • 4
    • 0000883820 scopus 로고
    • Structural modification of air-dried tendon collagen on heating
    • Bigi A, Fichera A, Roveri N and Koch M 1987 Structural modification of air-dried tendon collagen on heating Int. J. Biol. Macromol. 9 176-80
    • (1987) Int. J. Biol. Macromol. , vol.9 , pp. 176-180
    • Bigi, A.1    Fichera, A.2    Roveri, N.3    Koch, M.4
  • 6
    • 0030298346 scopus 로고    scopus 로고
    • The effect of diabetes on the viscoelastic properties of rat knee ligaments
    • Duquette J J, Grigg P and Hoffman A H 1996 The effect of diabetes on the viscoelastic properties of rat knee ligaments J. Biomech. Eng. 118 557-64
    • (1996) J. Biomech. Eng. , vol.118 , pp. 557-564
    • Duquette, J.J.1    Grigg, P.2    Hoffman, A.H.3
  • 7
    • 0001453963 scopus 로고
    • Cross-sectional area measurements for tendon specimen: A comparison of several methods
    • Ellis D G 1969 Cross-sectional area measurements for tendon specimen: a comparison of several methods J. Biomech. 2 175-86
    • (1969) J. Biomech. , vol.2 , pp. 175-186
    • Ellis, D.G.1
  • 11
    • 0023522201 scopus 로고
    • Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method
    • Iaconis F, Steindler R and Marionozzi G 1987 Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method J. Biomech. 20 1003-10
    • (1987) J. Biomech. , vol.20 , pp. 1003-1010
    • Iaconis, F.1    Steindler, R.2    Marionozzi, G.3
  • 12
    • 0033011211 scopus 로고    scopus 로고
    • Support stability influences postural responses to muscle vibration in humans
    • Ivanenko Y P, Vera L T and Kazennikov O V 1999 Support stability influences postural responses to muscle vibration in humans Eur. J. Neurosci. 11 647-54
    • (1999) Eur. J. Neurosci. , vol.11 , pp. 647-654
    • Ivanenko, Y.P.1    Vera, L.T.2    Kazennikov, O.V.3
  • 14
    • 0028069012 scopus 로고
    • Achilles tendon injuries in athletes
    • Kvist M 1994 Achilles tendon injuries in athletes Sports. Med. 18 173-201
    • (1994) Sports. Med. , vol.18 , pp. 173-201
    • Kvist, M.1
  • 15
    • 0024017397 scopus 로고
    • A new method for determining cross-sectional shape and area of soft tissues
    • Lee T Q and Woo S L 1988 A new method for determining cross-sectional shape and area of soft tissues J. Biomech. Eng. 110 110-14
    • (1988) J. Biomech. Eng. , vol.110 , pp. 110-114
    • Lee, T.Q.1    Woo, S.L.2
  • 16
    • 0008914687 scopus 로고
    • A non contact method for determining cross-sectional area of soft tissues
    • New Orleans: Orthopaedic Research Society
    • Njus G O and Njus N M 1986 A non contact method for determining cross-sectional area of soft tissues Proc. 32nd Annu. ORS (New Orleans: Orthopaedic Research Society)
    • (1986) Proc. 32nd Annu. ORS
    • Njus, G.O.1    Njus, N.M.2
  • 17
    • 0030248260 scopus 로고    scopus 로고
    • Cross-sectional area measurement of soft tissue. A new casting method
    • Race A and Amis A 1996 Cross-sectional area measurement of soft tissue. A new casting method J. Biomech. 9 1207-12
    • (1996) J. Biomech. , vol.9 , pp. 1207-1212
    • Race, A.1    Amis, A.2
  • 18
    • 0034942317 scopus 로고    scopus 로고
    • Non-contact dynamic analysis of mechanical behaviour of tendons by optical techniques
    • San Jose: SPIE
    • Revel G M, Scalise A and Scalise L 2001 Non-contact dynamic analysis of mechanical behaviour of tendons by optical techniques Proc. BIOS 2001 vol 4251 (San Jose: SPIE) pp 199-209
    • (2001) Proc. BIOS 2001 , vol.4251 , pp. 199-209
    • Revel, G.M.1    Scalise, A.2    Scalise, L.3
  • 19
    • 0035769847 scopus 로고    scopus 로고
    • In vitro tensile testing machine for vibration study of fresh rabbit Achilles tendon
    • Bellingham, WA: SPIE Optical Engineering Press
    • Revel G M, Scalise A, Scalise L and Pianosi A 2000 In vitro tensile testing machine for vibration study of fresh rabbit Achilles tendon Proc. SPIE Laser (Florence, 2000) vol 4606 (Bellingham, WA: SPIE Optical Engineering Press) pp 72-81
    • (2000) Proc. SPIE Laser (Florence, 2000) , vol.4606 , pp. 72-81
    • Revel, G.M.1    Scalise, A.2    Scalise, L.3    Pianosi, A.4
  • 20
    • 0031214941 scopus 로고    scopus 로고
    • In vitro fatigue of human tendons
    • Schechtman H and Bader D L 1997 In vitro fatigue of human tendons J. Biomech. 30 829-35
    • (1997) J. Biomech. , vol.30 , pp. 829-835
    • Schechtman, H.1    Bader, D.L.2
  • 21
    • 0029361198 scopus 로고
    • Stress in the Achilles tendon during a toppler-over movement in the ankle joint
    • Wallenböck E, Lang O and Lugner P 1995 Stress in the Achilles tendon during a toppler-over movement in the ankle joint J. Biomech. 29 1019-101
    • (1995) J. Biomech. , vol.29 , pp. 1019-1101
    • Wallenböck, E.1    Lang, O.2    Lugner, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.