-
1
-
-
0030339156
-
Metal-on-metal articulation for artificial hip joints: Laboratory study and clinical results
-
Streicher, R.M., Semlitsch, M., Schon, R., Weber, H. and Rieker, C. Metal-on-metal articulation for artificial hip joints: laboratory study and clinical results. IMechE J. Engng in Med., 1996, 210, H3, 223-232.
-
(1996)
IMechE J. Engng. in Med.
, vol.210
, Issue.H3
, pp. 223-232
-
-
Streicher, R.M.1
Semlitsch, M.2
Schon, R.3
Weber, H.4
Rieker, C.5
-
2
-
-
0033256670
-
Wear and lubrication of metal-on-metal hip implants
-
Chan, F.W., Bobyn J.D., Medley J.B., Krygier J.J., Yue S. and Tanzer, M. Wear and lubrication of metal-on-metal hip implants. Clin. Orthop., 1999, 369, 10-24.
-
(1999)
Clin. Orthop.
, vol.369
, pp. 10-24
-
-
Chan, F.W.1
Bobyn, J.D.2
Medley, J.B.3
Krygier, J.J.4
Yue, S.5
Tanzer, M.6
-
5
-
-
0033630259
-
A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
-
Goldsmith, A.A.J., Dowson, D., Isaac, G.H. and Lancaster, J.G. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. IMechE J. Engng in Med, 2000, 214, H1, 39-47.
-
(2000)
IMechE J. Engng. in Med.
, vol.214
, Issue.H1
, pp. 39-47
-
-
Goldsmith, A.A.J.1
Dowson, D.2
Isaac, G.H.3
Lancaster, J.G.4
-
6
-
-
0035045395
-
Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
-
Firkins, P.J., Tipper, J.L., Saadatzadeh, M.R., Ingham, E., Stone, M.H., Farrar, R. and Fisher, J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Bio-Med. Mat. and Eng., 2001, 11, 143-157.
-
(2001)
Bio-Med. Mat. and Eng.
, vol.11
, pp. 143-157
-
-
Firkins, P.J.1
Tipper, J.L.2
Saadatzadeh, M.R.3
Ingham, E.4
Stone, M.H.5
Farrar, R.6
Fisher, J.7
-
7
-
-
0033333279
-
Comparison of two cobalt-based alloys for use in metal-on-metal hip prostheses: Evaluation of the wer properties in a simulator
-
(Eds J.A. Disegi, R.L. Kennedy and R. Pilliar), ASTM STP 1365, ASTM, West Conshohocken, PA, U.S.A.
-
St. John, K.R., Poggie, R.A., Zardiackas, L.D. and Afflitto, R.M. Comparison of two cobalt-based alloys for use in metal-on-metal hip prostheses: evaluation of the wer properties in a simulator. Cobalt-Base Alloys for Biomedical Applications, (Eds J.A. Disegi, R.L. Kennedy and R. Pilliar), 1999, ASTM STP 1365, ASTM, West Conshohocken, PA, U.S.A., 145-155.
-
(1999)
Cobalt-Base Alloys for Biomedical Applications
, pp. 145-155
-
-
St. John, K.R.1
Poggie, R.A.2
Zardiackas, L.D.3
Afflitto, R.M.4
-
8
-
-
0035229408
-
The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
-
Smith, S.L., Dowson, D. and Goldsmith, A.A.J. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. IMechE J. Engng in Med, 2001, 215, H1, 161-170.
-
(2001)
IMechE J. Engng in Med.
, vol.215
, Issue.H1
, pp. 161-170
-
-
Smith, S.L.1
Dowson, D.2
Goldsmith, A.A.J.3
-
9
-
-
0029831455
-
In vivo wear of 3 types of metal on metal hip prostheses during 2 decades of use
-
McKellop, H., Park, S.H., Chiesa, R., Doorn, P., Lu, B., Normand, P. Grigoris, P. and Amstutz, H. In vivo wear of 3 types of metal on metal hip prostheses during 2 decades of use. Clin Orthop, 1996, 329 Suppl., S128-S140.
-
(1996)
Clin. Orthop.
, vol.329
, Issue.SUPPL.
-
-
McKellop, H.1
Park, S.H.2
Chiesa, R.3
Doorn, P.4
Lu, B.5
Normand, P.6
Grigoris, P.7
Amstutz, H.8
-
10
-
-
0003251758
-
In vivo tribological performance of 177 metal on metal hip arthroplasties
-
(Eds. C. Rieker, S. Oberholzer, and U. Wyss), Hans Huber
-
Rieker, C.B., Sch n̄, R. and Wyss, U.P. In vivo tribological performance of 177 metal on metal hip arthroplasties. World Tribology Forum in Arthroplasty, (Eds. C. Rieker, S. Oberholzer, and U. Wyss), 2001, Hans Huber, 137-142.
-
(2001)
World Tribology Forum in Arthroplasty
, pp. 137-142
-
-
Rieker, C.B.1
Schn, R.2
Wyss, U.P.3
-
11
-
-
3543099020
-
Intermittent motion as a simulator protocol for hip implants made from high elastic modulus materials
-
Institution of Mechanical Engineers, London, UK, Paper C601/094/2002
-
Medley, J.B., Bobyn, J.D., Krygier, J.J., Roter, G.E., Cheng, N.Y. and Chan, F.W. Intermittent motion as a simulator protocol for hip implants made from high elastic modulus materials. Proceedings of the International Conference: Engineers & Surgeons - Joined at the Hip, Institution of Mechanical Engineers, London, UK, Paper C601/094/2002.
-
Proceedings of the International Conference: Engineers & Surgeons - Joined at the Hip
-
-
Medley, J.B.1
Bobyn, J.D.2
Krygier, J.J.3
Roter, G.E.4
Cheng, N.Y.5
Chan, F.W.6
-
12
-
-
0029790389
-
Wear behavior and histopathology of classic cemented metal on metal hip endoprostheses
-
Willert, H.G., Buchorn, G.H..H., G b̄el, D., K ster, G., Schaffner, S., Schenk, R. and Semlitsch, M.. Wear behavior and histopathology of classic cemented metal on metal hip endoprostheses. Clin Orthop, 1996, 329 Suppl., S160-S186.
-
(1996)
Clin. Orthop.
, vol.329
, Issue.SUPPL.
-
-
Willert, H.G.1
Buchorn, G.H.2
Gbel, D.3
Kster, G.4
Schaffner, S.5
Schenk, R.6
Semlitsch, M.7
-
13
-
-
0030210397
-
Comparison of alloys and designs in a hip simulator study of metal on metal implants
-
Medley, J.B., Chan, F.W., Krygier, J.J. and Bobyn, J.D. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clin. Orthop., 1996, 329 Suppl., S148-S159.
-
(1996)
Clin. Orthop.
, vol.329
, Issue.SUPPL.
-
-
Medley, J.B.1
Chan, F.W.2
Krygier, J.J.3
Bobyn, J.D.4
-
14
-
-
0001566621
-
Simulator wear of some commercially available metal-on-metal hip implants
-
(Eds. J.J. Jacobs and T.L. Craig), ASTM STP 1346, ASTM, West Conshohocken, PA, U.S.A.
-
Medley, J.B., Dowling, J.M., Poggie, R.A., Krygier, J.J. and Bobyn, J.D. Simulator wear of some commercially available metal-on-metal hip implants. Alternative Bearing Surfaces in Total Joint Replacement, (Eds. J.J. Jacobs and T.L. Craig), 1998, ASTM STP 1346, ASTM, West Conshohocken, PA, U.S.A., 92-110.
-
(1998)
Alternative Bearing Surfaces in Total Joint Replacement
, pp. 92-110
-
-
Medley, J.B.1
Dowling, J.M.2
Poggie, R.A.3
Krygier, J.J.4
Bobyn, J.D.5
-
15
-
-
0036713559
-
Average patient walking activity approaches 2 million cycles per year
-
Silva, M., Shepherd, E.F., Jackson, W.O., Dorey, F.J. and Schmalzried, T.P. Average patient walking activity approaches 2 million cycles per year. J. of Arthroplasty, 2002, 17, 6, 693-697.
-
(2002)
J. of Arthroplasty
, vol.17
, Issue.6
, pp. 693-697
-
-
Silva, M.1
Shepherd, E.F.2
Jackson, W.O.3
Dorey, F.J.4
Schmalzried, T.P.5
-
16
-
-
0029833296
-
Systems view of optimizing metal on metal bearings
-
Schey, J.A. Systems view of optimizing metal on metal bearings. Clin. Orthop., 1996, 329 Suppl., S115-S127.
-
(1996)
Clin. Orthop.
, vol.329
, Issue.SUPPL.
-
-
Schey, J.A.1
-
17
-
-
0012164284
-
Elastohydrodynamic lubrication and wear of metal-on-metal hip implants
-
(Eds C. Rieker, S. Oberholzer and U. Wyss), Hans Huber
-
Medley, J.B., Bobyn, J.D., Krygier, J.J., Chan, F.W., Tanzer, M. and Roter, G.E. Elastohydrodynamic lubrication and wear of metal-on-metal hip implants. In World Tribology Forum in Arthroplasty, (Eds C. Rieker, S. Oberholzer and U. Wyss), 2001, Hans Huber, 125-136.
-
(2001)
World Tribology Forum in Arthroplasty
, pp. 125-136
-
-
Medley, J.B.1
Bobyn, J.D.2
Krygier, J.J.3
Chan, F.W.4
Tanzer, M.5
Roter, G.E.6
-
18
-
-
0036909674
-
Intermittent motion: A novel simulator protocol for the wear of metal-metal hip implants
-
Elsevier
-
Roter, G.E., Medley, J.B., Bobyn, J.D., Krygier, J.J. and Chan, F.W. (2002) Intermittent motion: a novel simulator protocol for the wear of metal-metal hip implants. Tribology Series 40, Elsevier, 367-376.
-
(2002)
Tribology Series 40
, pp. 367-376
-
-
Roter, G.E.1
Medley, J.B.2
Bobyn, J.D.3
Krygier, J.J.4
Chan, F.W.5
-
19
-
-
0002989262
-
Forces transmitted by joints in the human body
-
Paul, J.P. Forces transmitted by joints in the human body. Proc. Inst. Mech. Engrs., 1967, Part J, 181, 8-15.
-
(1967)
Proc. Inst. Mech. Engrs.
, vol.181
, Issue.PART J
, pp. 8-15
-
-
Paul, J.P.1
-
20
-
-
0030626485
-
Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants
-
Medley, J.B., Krygier, J.J., Bobyn, J.D., Chan, F.W., Lippincott, A. and Tanzer, M. Kinematics of the MATCO hip simulator and issues related to wear testing of metal-metal implants. IMechE J. Engng in Med, 1997, 211, H1, 89-99.
-
(1997)
IMechE J. Engng. in Med.
, vol.211
, Issue.H1
, pp. 89-99
-
-
Medley, J.B.1
Krygier, J.J.2
Bobyn, J.D.3
Chan, F.W.4
Lippincott, A.5
Tanzer, M.6
-
21
-
-
0000739709
-
Time-varying fluid film lubrication of metal-metal hip implants in simulator tests
-
(Eds. J.J. Jacobs and T.L. Craig), ASTM STP 1346, ASTM, West Conshohocken, PA, U.S.A.
-
Chan, F.W., Medley, J.B., Bobyn, J.D. and Krygier, J.J. Time-varying fluid film lubrication of metal-metal hip implants in simulator tests. Alternative Bearing Surfaces in Total Joint Replacement, (Eds. J.J. Jacobs and T.L. Craig), 1998, ASTM STP 1346, ASTM, West Conshohocken, PA, U.S.A., 111-128.
-
(1998)
Alternative Bearing Surfaces in Total Joint Replacement
, pp. 111-128
-
-
Chan, F.W.1
Medley, J.B.2
Bobyn, J.D.3
Krygier, J.J.4
-
22
-
-
0003774033
-
-
VNR Editions
-
Gellert, W., Küstner, H., Hellwich, M., Kästner, H. The VNR concise encyclopedia of mathematics. VNR Editions, 1977, 616-619.
-
(1977)
The VNR Concise Encyclopedia of Mathematics
, pp. 616-619
-
-
Gellert, W.1
Küstner, H.2
Hellwich, M.3
Kästner, H.4
-
23
-
-
0030454623
-
The engineering issues and wear performance of metal-on-metal hip implants
-
Chan, F.W., Bobyn, J.D., Medley, J.B., Krygier, J.J., Yue, S. and Tanzer, M. The engineering issues and wear performance of metal-on-metal hip implants. Clin. Orthop., 333, 96-107.
-
Clin. Orthop.
, vol.333
, pp. 96-107
-
-
Chan, F.W.1
Bobyn, J.D.2
Medley, J.B.3
Krygier, J.J.4
Yue, S.5
Tanzer, M.6
|