메뉴 건너뛰기




Volumn 41, Issue , 2003, Pages 291-296

Advances in simulator testing of orthopaedic joint prostheses

Author keywords

[No Author keywords available]

Indexed keywords

CERAMICS; CONFERENCE PAPER; HIP PROSTHESIS; JOINT LAXITY; JOINT PROSTHESIS; LUBRICATION; MATERIALS TESTING; SIMULATION; WALKING;

EID: 0043212350     PISSN: 01678922     EISSN: None     Source Type: Book Series    
DOI: 10.1016/s0167-8922(03)80141-4     Document Type: Conference Paper
Times cited : (14)

References (18)
  • 2
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of the centres of Alumina-Alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
    • J E Nevelos, E Ingham, C Doyle, R Streicher, A B Nevelos, W Walter, J Fisher, "Microseparation of the centres of Alumina-Alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns". Journal of Arthroplasty, 15, 793-795, 2000.
    • (2000) Journal of Arthroplasty , vol.15 , pp. 793-795
    • Nevelos, J.E.1    Ingham, E.2    Doyle, C.3    Streicher, R.4    Nevelos, A.B.5    Walter, W.6    Fisher, J.7
  • 4
    • 0035482516 scopus 로고    scopus 로고
    • Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator
    • J L Tipper, P J Firkins, A A Besong, P S M Barbour, J Nevelos, M H Stone, E Ingham, J Fisher, "Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator". Wear 250, 120-128, 2001.
    • (2001) Wear , vol.250 , pp. 120-128
    • Tipper, J.L.1    Firkins, P.J.2    Besong, A.A.3    Barbour, P.S.M.4    Nevelos, J.5    Stone, M.H.6    Ingham, E.7    Fisher, J.8
  • 5
    • 0041612268 scopus 로고    scopus 로고
    • Influence of microseparation and joint laxity on wear of ceramic on polyethylene, ceramic on ceramic and metal on metal total hip prostheses
    • Feb
    • S Williams, T D Stewart, E Ingham, M H Stone, J Fisher, "Influence of microseparation and joint laxity on wear of ceramic on polyethylene, ceramic on ceramic and metal on metal total hip prostheses". Proceedings of the British Hip Society, Feb. 2002.
    • (2002) Proceedings of the British Hip Society
    • Williams, S.1    Stewart, T.D.2    Ingham, E.3    Stone, M.H.4    Fisher, J.5
  • 7
    • 0030625634 scopus 로고    scopus 로고
    • Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements
    • M Semlitsch, H G Willert, "Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements". Proc. Inst. Mech. Eng.,H211, 73-88, 1997.
    • (1997) Proc. Inst. Mech. Eng. , vol.H211 , pp. 73-88
    • Semlitsch, M.1    Willert, H.G.2
  • 9
    • 0033775261 scopus 로고    scopus 로고
    • Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear
    • I C Clarke, A Gustafson. "Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear". Clin. Orthop. Rel. Res., 379, 34-40, 2000.
    • (2000) Clin. Orthop. Rel. Res. , vol.379 , pp. 34-40
    • Clarke, I.C.1    Gustafson, A.2
  • 12
    • 0041612273 scopus 로고    scopus 로고
    • Metal on metal articulation in total hip replacement
    • I D Learmouth Ed., Springer-Verlag
    • P Roberts P Grigoris, "Metal on metal articulation in total hip replacement", In: Interfaces in Total Hip Arthroplasty, I D Learmouth Ed., 121-133, Springer-Verlag, 1999.
    • (1999) Interfaces in Total Hip Arthroplasty , pp. 121-133
    • Roberts, P.1    Grigoris, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.