메뉴 건너뛰기




Volumn 89, Issue 8, 2003, Pages 823-824

Endovascular treatment of thoracic aortic disease

Author keywords

[No Author keywords available]

Indexed keywords

AORTA CLAMPING; AORTA DISEASE; AORTA DISSECTING ANEURYSM; AORTA RUPTURE; BALLOON OCCLUSION; CEREBROSPINAL FLUID DRAINAGE; CEREBROSPINAL FLUID PRESSURE; COLLATERAL CIRCULATION; COMPUTER ASSISTED TOMOGRAPHY; EDITORIAL; ENDOVASCULAR SURGERY; HUMAN; IMAGE QUALITY; ISCHEMIA; MINIMALLY INVASIVE SURGERY; PARAPLEGIA; PRIORITY JOURNAL; REVASCULARIZATION; SPINAL CORD BLOOD FLOW; STENT; SURGICAL TECHNIQUE; THORACIC AORTA; THORACIC AORTA ANEURYSM; THROMBOSIS; TREATMENT CONTRAINDICATION; TREATMENT INDICATION;

EID: 0043169621     PISSN: 13556037     EISSN: None     Source Type: Journal    
DOI: 10.1136/heart.89.8.823     Document Type: Editorial
Times cited : (7)

References (19)
  • 1
    • 0026267990 scopus 로고
    • Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction
    • Volodos NL, Karpovich IP, Troyan VI. Clinical experience of the use of self-fixing synthetic prostheses for remote endoprosthetics of the thoracic and abdominal aorta and iliac arteries through the femoral artery and as intraoperative endoprosthesis for aorta reconstruction. Vasa 1991;33(suppl):93-5.
    • (1991) Vasa , vol.33 , Issue.SUPPL. , pp. 93-95
    • Volodos, N.L.1    Karpovich, I.P.2    Troyan, V.I.3
  • 2
    • 0034920488 scopus 로고    scopus 로고
    • Thoracic aortic stent grafts - Early experience from two centres using commercially available devices
    • Taylor PR, Gaines PA, McGuinness CL, et al. Thoracic aortic stent grafts - early experience from two centres using commercially available devices. Eur J Vasc Endovasc Surg 2001;22:70-6.
    • (2001) Eur J Vasc Endovasc Surg , vol.22 , pp. 70-76
    • Taylor, P.R.1    Gaines, P.A.2    McGuinness, C.L.3
  • 3
    • 0031739777 scopus 로고    scopus 로고
    • The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta
    • Dake MD, Miller DC, Mitchell RS, et al. The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg 1998;116:689-703; discussion 703-4.
    • (1998) J Thorac Cardiovasc Surg , vol.116 , pp. 689-703
    • Dake, M.D.1    Miller, D.C.2    Mitchell, R.S.3
  • 4
    • 0020264029 scopus 로고
    • Thoracic aortic aneurysms: A population based study
    • Bickerstaff LK, Pairolero PC, Hollier LH. Thoracic aortic aneurysms: a population based study. Surgery 1982;92:1103-8.
    • (1982) Surgery , vol.92 , pp. 1103-1108
    • Bickerstaff, L.K.1    Pairolero, P.C.2    Hollier, L.H.3
  • 5
    • 0024535244 scopus 로고
    • Increasing incidence of aortic aneurysms in England and Wales
    • Fowkes FG, MacIntyre CC, Ruckley CV. Increasing incidence of aortic aneurysms in England and Wales. BMJ 1989;298:33-5.
    • (1989) BMJ , vol.298 , pp. 33-35
    • Fowkes, F.G.1    MacIntyre, C.C.2    Ruckley, C.V.3
  • 6
    • 0036616575 scopus 로고    scopus 로고
    • Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs
    • Gorich J, Asquan Y, Seifarth H, et al. Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 2002;9(suppl 2):1139-43.
    • (2002) J Endovasc Ther , vol.9 , Issue.2 SUPPL. , pp. 1139-1143
    • Gorich, J.1    Asquan, Y.2    Seifarth, H.3
  • 7
    • 0033586990 scopus 로고    scopus 로고
    • Endovascular stent-graft placement for the treatment of acute aortic dissection
    • Dake MD, Kato N, Mitchell RS, et al. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 1999;340:1546-52.
    • (1999) N Engl J Med , vol.340 , pp. 1546-1552
    • Dake, M.D.1    Kato, N.2    Mitchell, R.S.3
  • 8
    • 0025689665 scopus 로고
    • Treatment of patients with aortic dissection presenting with peripheral vascular complications
    • Fann JI, Sarris GE, Mitchell RS. Treatment of patients with aortic dissection presenting with peripheral vascular complications. Ann Surg 1990;212:705-13.
    • (1990) Ann Surg , vol.212 , pp. 705-713
    • Fann, J.I.1    Sarris, G.E.2    Mitchell, R.S.3
  • 9
    • 0023848099 scopus 로고
    • Vascular complications associated with spontaneous aortic dissection
    • Cambria RP, Brewster DC, Gertler J. Vascular complications associated with spontaneous aortic dissection. J Vasc Surg 1988;7:199-209.
    • (1988) J Vasc Surg , vol.7 , pp. 199-209
    • Cambria, R.P.1    Brewster, D.C.2    Gertler, J.3
  • 10
    • 0034673103 scopus 로고    scopus 로고
    • The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease
    • Hagan PG, Nienaber CA, Isselbacher EM. The International Registry of Acute Aortic Dissection (IRAD) - new insights into an old disease. JAMA 2000;283:897-903.
    • (2000) JAMA , vol.283 , pp. 897-903
    • Hagan, P.G.1    Nienaber, C.A.2    Isselbacher, E.M.3
  • 11
    • 0028541286 scopus 로고
    • Treatment of aortic dissections with percutaneous intravascular endoprosthesis: Comparison of covered and bare stents
    • Kato N, Hirano T, Takeda K. Treatment of aortic dissections with percutaneous intravascular endoprosthesis: comparison of covered and bare stents. J Vasc Interv Radiol 1994;5:805-12.
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 805-812
    • Kato, N.1    Hirano, T.2    Takeda, K.3
  • 12
    • 0035877219 scopus 로고    scopus 로고
    • False lumen patency as a predictor of late outcome in aortic dissection
    • Bernard Y, Zimmermann H, Chocron S. False lumen patency as a predictor of late outcome in aortic dissection. Am J Cardiol 2001;87:1378-82.
    • (2001) Am J Cardiol , vol.87 , pp. 1378-1382
    • Bernard, Y.1    Zimmermann, H.2    Chocron, S.3
  • 13
    • 0033586995 scopus 로고    scopus 로고
    • Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement
    • Nienaber CA, Fattori R, Lund G, et al. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med 1999;340:1539-45.
    • (1999) N Engl J Med , vol.340 , pp. 1539-1545
    • Nienaber, C.A.1    Fattori, R.2    Lund, G.3
  • 14
    • 0042555974 scopus 로고    scopus 로고
    • Complications of stent graft placement in the thoracic aorta
    • Branchereau A, Jacobs M, eds. New York: Futura Publishing Company
    • Rehders TC, Nienaber CA. Complications of stent graft placement in the thoracic aorta. In: Branchereau A, Jacobs M, eds. Complications in vascular and endovascular surgery part 1. New York: Futura Publishing Company, 2001:185-92.
    • (2001) Complications in Vascular and Endovascular Surgery Part 1 , pp. 185-192
    • Rehders, T.C.1    Nienaber, C.A.2
  • 15
    • 0027367593 scopus 로고
    • Variables predictive of outcome in 832 patients undergoing repairs of the descending thoracic aorta
    • Svensson LG, Crawford ES, Hess K. Variables predictive of outcome in 832 patients undergoing repairs of the descending thoracic aorta. Chest 1993;104:1248-53.
    • (1993) Chest , vol.104 , pp. 1248-1253
    • Svensson, L.G.1    Crawford, E.S.2    Hess, K.3
  • 16
    • 0035653526 scopus 로고    scopus 로고
    • Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms
    • Gravereaux EC, Faries PL, Burks JA, et al. Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms. J Vasc Surg 2001;34:997-1003.
    • (2001) J Vasc Surg , vol.34 , pp. 997-1003
    • Gravereaux, E.C.1    Faries, P.L.2    Burks, J.A.3
  • 17
    • 0026570533 scopus 로고
    • Long-term experience with descending aortic dissection: The complication-specific approach
    • Elefteriades JA, Hartleroad J, Gusberg RJ. Long-term experience with descending aortic dissection: the complication-specific approach. Ann Thorac Surg 1992;53:11-21.
    • (1992) Ann Thorac Surg , vol.53 , pp. 11-21
    • Elefteriades, J.A.1    Hartleroad, J.2    Gusberg, R.J.3
  • 18
    • 0036841672 scopus 로고    scopus 로고
    • Assessment of spinal cord integrity during thoracoabdominal aortic aneurysm repair
    • Jacobs MJ, Elenbaas TW, Schurink GW, et al. Assessment of spinal cord integrity during thoracoabdominal aortic aneurysm repair. Ann Thorac Surg 2002;74:S1864-6; discussion S1892-8.
    • (2002) Ann Thorac Surg , vol.74
    • Jacobs, M.J.1    Elenbaas, T.W.2    Schurink, G.W.3
  • 19
    • 0031979746 scopus 로고    scopus 로고
    • Preliminary report on prediction of spinal cord ischemia in endovascular stent graft repair of thoracic aortic aneurysm by retrievable stent graft
    • Ishimaru S, Kawaguchi S, Koizumi N, et al. Preliminary report on prediction of spinal cord ischemia in endovascular stent graft repair of thoracic aortic aneurysm by retrievable stent graft. J Thorac Cardiovasc Surg 1998;115:811-8.
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 811-818
    • Ishimaru, S.1    Kawaguchi, S.2    Koizumi, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.