메뉴 건너뛰기




Volumn 15, Issue SUPPL., 2003, Pages

Chiroptical detection during liquid chromatography: Deconvolution of overlapping peaks of enantiomers and its applications

Author keywords

Circular dichroism; Computer programs for deconvolution; Electronic; Enantiomerization during HPLC; Optical purity; Peak purity; Polarimetry

Indexed keywords

BISTHIOAMIDE; CHROMENE DERIVATIVE; FLAVANONE; INDOLINOSPIROCHROMENE; PYRAN; THIOAMIDE; UNCLASSIFIED DRUG;

EID: 0043166725     PISSN: 08990042     EISSN: None     Source Type: Journal    
DOI: 10.1002/chir.10275     Document Type: Conference Paper
Times cited : (20)

References (47)
  • 1
    • 1642560884 scopus 로고    scopus 로고
    • HPLC on chiral nonracemic sorbents with circular dichroism detection: Stereoisomers formed by 1,3-dipolar cycloadditions
    • in press
    • Pospisil J, Travnicek M. Mannschreck A, Potacek M. HPLC on chiral nonracemic sorbents with circular dichroism detection: stereoisomers formed by 1,3-dipolar cycloadditions. Chem Listy (Prague) 2003;97 (in press).
    • (2003) Chem Listy (Prague) , pp. 97
    • Pospisil, J.1    Travnicek, M.2    Mannschreck, A.3    Potacek, M.4
  • 2
    • 0000434092 scopus 로고
    • Enantiomerization during HPLC on an optically active sorbent, Deconvolution of experimental chromatograms
    • Mannschreck A, Kiessl L. Enantiomerization during HPLC on an optically active sorbent, Deconvolution of experimental chromatograms. Chromatographia 1989;28:263-266.
    • (1989) Chromatographia , vol.28 , pp. 263-266
    • Mannschreck, A.1    Kiessl, L.2
  • 3
    • 0035108933 scopus 로고    scopus 로고
    • Recent advances in chiral detection for high performance liquid chromatography
    • Bobbitt DR, Linder SW. Recent advances in chiral detection for high performance liquid chromatography. Trends Anal Chem 2001;20:111-123.
    • (2001) Trends Anal Chem , vol.20 , pp. 111-123
    • Bobbitt, D.R.1    Linder, S.W.2
  • 4
    • 0035449011 scopus 로고    scopus 로고
    • Miniaturization of enantioselective detectors
    • Edkins TJ, Bobbitt DR. Miniaturization of enantioselective detectors. Anal Chem 2001;73:488A-496A.
    • (2001) Anal Chem , vol.73
    • Edkins, T.J.1    Bobbitt, D.R.2
  • 5
    • 0347171857 scopus 로고    scopus 로고
    • Circular dichroism spectroscopy in the analysis of chiral drugs
    • Aboul-Enein HY, Wainer IW, editors. New York: Wiley
    • Salvadori P, Rosini C, Bertucci C. Circular dichroism spectroscopy in the analysis of chiral drugs. In: Aboul-Enein HY, Wainer IW, editors. The impact of stereochemistry on drug development and use. New York: Wiley; 1997. p 493-519.
    • (1997) The Impact of Stereochemistry on Drug Development and Use , pp. 493-519
    • Salvadori, P.1    Rosini, C.2    Bertucci, C.3
  • 6
    • 0003426458 scopus 로고    scopus 로고
    • HPLC-CD: Stereochemical analysis at work
    • Berova N, Nakanishi K, Woody RW, editors. New York: Wiley-VCH; 2nd ed.
    • Salvadori P, Di Bari L, Pescitelli G. HPLC-CD: Stereochemical analysis at work. In: Berova N, Nakanishi K, Woody RW, editors. Circular dichroism. Principles and applications. New York: Wiley-VCH; 2000, 2nd ed. p 797-817.
    • (2000) Circular Dichroism. Principles and Applications , pp. 797-817
    • Salvadori, P.1    Di Bari, L.2    Pescitelli, G.3
  • 8
    • 84985598494 scopus 로고
    • Liquid chromatography of enantiomers: Determination of enantiomeric purity in spite of extensive peak overlap
    • Mannschreck A, Mintas M, Becher G, Stühler G. Liquid chromatography of enantiomers: determination of enantiomeric purity in spite of extensive peak overlap. Angew Chem Int Ed 1980;19:469-470. Angew Chem 1980;92:490-491.
    • (1980) Angew Chem Int Ed , vol.19 , pp. 469-470
    • Mannschreck, A.1    Mintas, M.2    Becher, G.3    Stühler, G.4
  • 9
    • 84985598494 scopus 로고
    • Mannschreck A, Mintas M, Becher G, Stühler G. Liquid chromatography of enantiomers: determination of enantiomeric purity in spite of extensive peak overlap. Angew Chem Int Ed 1980;19:469-470. Angew Chem 1980;92:490-491.
    • (1980) Angew Chem , vol.92 , pp. 490-491
  • 10
    • 0041614889 scopus 로고
    • Chromatographische enantiomerentrennung an cellulose-triacetat im grammaßstab
    • Werner A. Chromatographische Enantiomerentrennung an Cellulose-triacetat im Grammaßstab. Kontakte (Darmstadt) 1989;Nr.3:50-56. Chem Abstr 1990;112:177 577.
    • (1989) Kontakte (Darmstadt) , vol.3 , pp. 50-56
    • Werner, A.1
  • 11
    • 0042616877 scopus 로고
    • Werner A. Chromatographische Enantiomerentrennung an Cellulose-triacetat im Grammaßstab. Kontakte (Darmstadt) 1989;Nr.3:50-56. Chem Abstr 1990;112:177 577.
    • (1990) Chem Abstr , vol.112 , pp. 177577
  • 13
    • 0026663784 scopus 로고
    • Chiroptical detection during liquid chromatography. Applications to stereoanalysis and stereodynamics
    • Mannschreck A. Chiroptical detection during liquid chromatography. Applications to stereoanalysis and stereodynamics. Chirality 1992;4: 163-169.
    • (1992) Chirality , vol.4 , pp. 163-169
    • Mannschreck, A.1
  • 14
    • 0002131505 scopus 로고    scopus 로고
    • Polarimetric detection during liquid chromatography. Sensitivity and computer support
    • Brandl F, Pustet N, Mannschreck A. Polarimetric detection during liquid chromatography. Sensitivity and computer support. GIT Labor-Fachz. 1999;43:19-22. Chem Abstr 1999;130:176 900.
    • (1999) GIT Labor-Fachz , vol.43 , pp. 19-22
    • Brandl, F.1    Pustet, N.2    Mannschreck, A.3
  • 15
    • 0042616879 scopus 로고    scopus 로고
    • Brandl F, Pustet N, Mannschreck A. Polarimetric detection during liquid chromatography. Sensitivity and computer support. GIT Labor-Fachz. 1999;43:19-22. Chem Abstr 1999;130:176 900.
    • (1999) Chem Abstr , vol.130 , pp. 176900
  • 16
    • 0001618665 scopus 로고    scopus 로고
    • Applications of a novel type of detector for liquid chromatography of chiral compounds
    • Brandl F, Pustet N, Mannschreck A. Applications of a novel type of detector for liquid chromatography of chiral compounds. Int Lab 1999; 29:10C-15C.
    • (1999) Int Lab , vol.29
    • Brandl, F.1    Pustet, N.2    Mannschreck, A.3
  • 17
    • 0032145778 scopus 로고    scopus 로고
    • Development of a bimodal polarimetric response model for improved quantitation of enantiomeric mixtures under conditions of poor chromatographic resolution
    • Lodevico RG, Bobbitt DR, Edkins TJ. Development of a bimodal polarimetric response model for improved quantitation of enantiomeric mixtures under conditions of poor chromatographic resolution. Talanta 1998;46:907-914.
    • (1998) Talanta , vol.46 , pp. 907-914
    • Lodevico, R.G.1    Bobbitt, D.R.2    Edkins, T.J.3
  • 18
    • 0042616878 scopus 로고    scopus 로고
    • http://www.pdr-chiral.com.
  • 19
    • 0036052072 scopus 로고    scopus 로고
    • Quantitative analysis of incomplete HPLC resolution of enantiomers. Fit of polarimetric detection for D- and L-phenylalanine to a Gaussian function
    • Edkins TJ, Meier PC, Shah RD, Bobbitt DR, Saranadasa H, Lodevico RD. Quantitative analysis of incomplete HPLC resolution of enantiomers. Fit of polarimetric detection for D- and L-phenylalanine to a Gaussian function. Enantiomer 2002;7:11-22.
    • (2002) Enantiomer , vol.7 , pp. 11-22
    • Edkins, T.J.1    Meier, P.C.2    Shah, R.D.3    Bobbitt, D.R.4    Saranadasa, H.5    Lodevico, R.D.6
  • 20
    • 0001286781 scopus 로고
    • Simultaneous monitoring of light-absorption and optical activity in liquid chromatography of chiral substances
    • Drake AF, Gould JM, Mason SF. Simultaneous monitoring of light-absorption and optical activity in liquid chromatography of chiral substances. J Chromatogr 1980;202:239-245.
    • (1980) J Chromatogr , vol.202 , pp. 239-245
    • Drake, A.F.1    Gould, J.M.2    Mason, S.F.3
  • 21
    • 0006173295 scopus 로고    scopus 로고
    • 1′,3′,3′-Trimethyl-6-nitrospiro[2H-1-benzopyran-2, 2′-indoline]: Its thermal enantiomerization and the equilibrium with its merocyanine
    • Kiesswetter R, Pustet N, Brandl F, Mannschreck A. 1′,3′,3′-Trimethyl-6-nitrospiro[2H-1-benzopyran-2, 2′-indoline]: its thermal enantiomerization and the equilibrium with its merocyanine. Tetrahedron Asymm 1999;10:4677-4687.
    • (1999) Tetrahedron Asymm , vol.10 , pp. 4677-4687
    • Kiesswetter, R.1    Pustet, N.2    Brandl, F.3    Mannschreck, A.4
  • 22
    • 0030952689 scopus 로고    scopus 로고
    • On-column enantiomerization of 3-hydroxybenzodiazepines during chiral liquid chromatography with optical rotation detection
    • Nishikawa T, Hayashi Y, Suzuki S, Kubo H, Obtani H. On-column enantiomerization of 3-hydroxybenzodiazepines during chiral liquid chromatography with optical rotation detection. J Chromatogr A 1997; 767:93-100.
    • (1997) J Chromatogr A , vol.767 , pp. 93-100
    • Nishikawa, T.1    Hayashi, Y.2    Suzuki, S.3    Kubo, H.4    Obtani, H.5
  • 23
    • 0034308973 scopus 로고    scopus 로고
    • Deconvolution of composite chromatographic peaks by simultaneous dual detections
    • Gergely A, Horvath P, Noszal B. Deconvolution of composite chromatographic peaks by simultaneous dual detections. J Chromatogr Sci 2000;38:425-429.
    • (2000) J Chromatogr Sci , vol.38 , pp. 425-429
    • Gergely, A.1    Horvath, P.2    Noszal, B.3
  • 24
    • 0042115767 scopus 로고    scopus 로고
    • Thesis. University of Regensburg
    • Kiesswetter R. Thesis. University of Regensburg; 2001. p 207, 210.
    • (2001) , pp. 207
    • Kiesswetter, R.1
  • 25
    • 84984167209 scopus 로고
    • Determination of enantiomeric purity in spite of incomplete separation
    • Mannschreck A. Eiglsperger A, Stühler G. Determination of enantiomeric purity in spite of incomplete separation. Chem Ber 1982;115: 1568-1575.
    • (1982) Chem Ber , vol.115 , pp. 1568-1575
    • Mannschreck, A.1    Eiglsperger, A.2    Stühler, G.3
  • 26
    • 0035895801 scopus 로고    scopus 로고
    • The rotation angle/absorbance ratio of chiral molecules. Its possible use for on-line analysis during preparative separations of enantiomers
    • and references cited
    • Brandl F, Pustet N, Mannschreck A. The rotation angle/absorbance ratio of chiral molecules. Its possible use for on-line analysis during preparative separations of enantiomers. J Chromatogr A 2001;909:147-154, and references cited.
    • (2001) J Chromatogr A , vol.909 , pp. 147-154
    • Brandl, F.1    Pustet, N.2    Mannschreck, A.3
  • 27
    • 0000099520 scopus 로고    scopus 로고
    • Terms for the quantitation of a mixture of stereoisomers
    • and references cited
    • Schurig V. Terms for the quantitation of a mixture of stereoisomers. Enantiomer 1996;1:139-143, and references cited.
    • (1996) Enantiomer , vol.1 , pp. 139-143
    • Schurig, V.1
  • 28
    • 0041614888 scopus 로고    scopus 로고
    • Thesis. University of Regensburg
    • Brandl F. Thesis. University of Regensburg; 2000. p 56, 63, 305.
    • (2000) , pp. 56
    • Brandl, F.1
  • 29
    • 0027222905 scopus 로고
    • Chiral analysis based on polarimetric detection
    • and references cited
    • Goodall DM. Chiral analysis based on polarimetric detection. Trends Anal Chem 1993;12:177-184, and references cited.
    • (1993) Trends Anal Chem , vol.12 , pp. 177-184
    • Goodall, D.M.1
  • 31
    • 0034604765 scopus 로고    scopus 로고
    • On-line monitoring of enantiomer concentration in chiral simulated moving bed chromatography
    • Zenoni G, Pedeferri MP, Mazzotti M, Morbidelli M. On-line monitoring of enantiomer concentration in chiral simulated moving bed chromatography. J Chromatogr A 2000;888:73-83.
    • (2000) J Chromatogr A , vol.888 , pp. 73-83
    • Zenoni, G.1    Pedeferri, M.P.2    Mazzotti, M.3    Morbidelli, M.4
  • 32
    • 0037168989 scopus 로고    scopus 로고
    • Effect of the homogeneity of the column set on the performance of a simulated moving bed unit; experimental study
    • Mihlbacher K, Jupke A, Seidel-Morgenstern A, Schmidt-Traub H, Guiochon G. Effect of the homogeneity of the column set on the performance of a simulated moving bed unit; experimental study. J Chromatogr A 2002;944:3-22.
    • (2002) J Chromatogr A , vol.944 , pp. 3-22
    • Mihlbacher, K.1    Jupke, A.2    Seidel-Morgenstern, A.3    Schmidt-Traub, H.4    Guiochon, G.5
  • 33
    • 0030985213 scopus 로고    scopus 로고
    • Determination of enantiomeric excess using a chiral selective separation mode and polarimetric detection
    • Lodevico RG, Bobbitt DR, Edkins TJ. Determination of enantiomeric excess using a chiral selective separation mode and polarimetric detection. Talanta 1997;44:1353-1363.
    • (1997) Talanta , vol.44 , pp. 1353-1363
    • Lodevico, R.G.1    Bobbitt, D.R.2    Edkins, T.J.3
  • 34
    • 0042115766 scopus 로고    scopus 로고
    • Thesis. University of Regensburg
    • Hofweber M. Thesis. University of Regensburg; 2000. p 66, 148, 303.
    • (2000) , pp. 66
    • Hofweber, M.1
  • 35
    • 0032561239 scopus 로고    scopus 로고
    • Axially chiral thioamides of acrylic acid: Correlated and uncorrelated internal rotations
    • Cf. Kuttenberger M, Frieser M, Hofweber M, Mannschreck A. Axially chiral thioamides of acrylic acid: correlated and uncorrelated internal rotations. Tetrahedron Asymm 1998;9:3629-3645.
    • (1998) Tetrahedron Asymm , vol.9 , pp. 3629-3645
    • Kuttenberger, M.1    Frieser, M.2    Hofweber, M.3    Mannschreck, A.4
  • 36
    • 0345818872 scopus 로고    scopus 로고
    • The enantiomers of 7aH-Cyclopenta[b]pyran-7-ones and their thermal racemization
    • Zimmermann T, Pustet N, Mannschreck A. The enantiomers of 7aH-Cyclopenta[b]pyran-7-ones and their thermal racemization. J Prakt Chem 1999;341:395-397.
    • (1999) J Prakt Chem , vol.341 , pp. 395-397
    • Zimmermann, T.1    Pustet, N.2    Mannschreck, A.3
  • 37
    • 0043117705 scopus 로고
    • 7aH-Cyclopenta[b]pyran-7-one durch Ringtransformation von 2,4,6-Triarylpyryliumsalzen mit acyclischen 1,2-Diketonen
    • Zimmermann T, Fischer GW, Kutscharsky L. 7aH-Cyclopenta[b]pyran-7-one durch Ringtransformation von 2,4,6-Triarylpyryliumsalzen mit acyclischen 1,2-Diketonen. J Prakt Chem 1989;331:293-305.
    • (1989) J Prakt Chem , vol.331 , pp. 293-305
    • Zimmermann, T.1    Fischer, G.W.2    Kutscharsky, L.3
  • 38
    • 0037148430 scopus 로고    scopus 로고
    • Diastereoselective reaction of (MP)-pentahelicene-7,8-dione with trans-cyclohexane-1,2-diamine. Thermal and photochemical transformations of its product
    • Putala M, Kastner-Pustet N, Mannschreck A. Diastereoselective reaction of (MP)-pentahelicene-7,8-dione with trans-cyclohexane-1,2-diamine. Thermal and photochemical transformations of its product. Tetrahedron Asymm 2001;12:3333-3342.
    • (2001) Tetrahedron Asymm , vol.12 , pp. 3333-3342
    • Putala, M.1    Kastner-Pustet, N.2    Mannschreck, A.3
  • 39
    • 0034899754 scopus 로고    scopus 로고
    • Determination of enantiomerization barriers by dynamic and stopped-flow chromatographic methods
    • Trapp O, Schoetz G, Schurig V. Determination of enantiomerization barriers by dynamic and stopped-flow chromatographic methods. Chirality 2001;13:403-414.
    • (2001) Chirality , vol.13 , pp. 403-414
    • Trapp, O.1    Schoetz, G.2    Schurig, V.3
  • 40
    • 0000501335 scopus 로고
    • Enantiomers of 2,2′-spirobichromenes: Energy barrier for thermal racemization during HPLC on tribenzoylcellulose
    • Stephan B, Zinner H, Kastner F, Mannschreck A. Enantiomers of 2,2′-spirobichromenes: energy barrier for thermal racemization during HPLC on tribenzoylcellulose. Chimia 1990;44:336-338.
    • (1990) Chimia , vol.44 , pp. 336-338
    • Stephan, B.1    Zinner, H.2    Kastner, F.3    Mannschreck, A.4
  • 41
    • 0000494290 scopus 로고
    • The significance of the HPLC time scale: An example of interconvertible enantiomers
    • Mannschreck A, Zinner H, Pustet N. The significance of the HPLC time scale: an example of interconvertible enantiomers. Chimia 1989; 43:165-166.
    • (1989) Chimia , vol.43 , pp. 165-166
    • Mannschreck, A.1    Zinner, H.2    Pustet, N.3
  • 42
    • 0034453347 scopus 로고    scopus 로고
    • The use of computerized peak deconvolution for determination of energy barrier to enantiomerization in dynamic gas chromatography
    • Krupcik J, Oswald P, Spanik I, Majek P, Bajdichova M, Sandra P, Armstrong DW. The use of computerized peak deconvolution for determination of energy barrier to enantiomerization in dynamic gas chromatography. J Microcolumn Separ 2000;12:630-636.
    • (2000) J Microcolumn Separ , vol.12 , pp. 630-636
    • Krupcik, J.1    Oswald, P.2    Spanik, I.3    Majek, P.4    Bajdichova, M.5    Sandra, P.6    Armstrong, D.W.7
  • 43
    • 0034449159 scopus 로고    scopus 로고
    • On the use of a peak deconvolution procedure for the determination of energy barrier to enantiomerization in dynamic chromatography
    • Krupcik J, Oswald P, Spanik I, Majek P, Bajdichova M, Sandra P, Armstrong DW. On the use of a peak deconvolution procedure for the determination of energy barrier to enantiomerization in dynamic chromatography. Analysis 2000;28:859-863.
    • (2000) Analysis , vol.28 , pp. 859-863
    • Krupcik, J.1    Oswald, P.2    Spanik, I.3    Majek, P.4    Bajdichova, M.5    Sandra, P.6    Armstrong, D.W.7
  • 44
    • 0035896457 scopus 로고    scopus 로고
    • Approximation function for the direct calculation of rate constants and Gibbs activation energies of enantiomerization of racemic mixtures from chromatographic parameters in dynamic chromatography
    • Trapp O, Schurig V. Approximation function for the direct calculation of rate constants and Gibbs activation energies of enantiomerization of racemic mixtures from chromatographic parameters in dynamic chromatography. J Chromatogr A 2001;911:167-175.
    • (2001) J Chromatogr A , vol.911 , pp. 167-175
    • Trapp, O.1    Schurig, V.2
  • 45
    • 0036223102 scopus 로고    scopus 로고
    • Evaluation of reversible and irreversible models for the determination of the enantiomerization energy barrier for N-(p-methoxybenzyl)-1,3,2-benzodithiazol-1-oxide by supercrifical fluid chromatography
    • Oswald P, Desmet K, Sandra P, Krupcik J, Armstrong DW. Evaluation of reversible and irreversible models for the determination of the enantiomerization energy barrier for N-(p-methoxybenzyl)-1,3,2-benzodithiazol-1-oxide by supercrifical fluid chromatography. Chirality 2002; 14;334-339.
    • (2002) Chirality , vol.14 , pp. 334-339
    • Oswald, P.1    Desmet, K.2    Sandra, P.3    Krupcik, J.4    Armstrong, D.W.5
  • 46
    • 0036313224 scopus 로고    scopus 로고
    • Novel direct access to enantiomerization barriers from peak profiles in enantioselective dynamic chromatography: Enantiomerization of dialkyl-1,3-allenedicarboxylates
    • Trapp O, Schurig V. Novel direct access to enantiomerization barriers from peak profiles in enantioselective dynamic chromatography: enantiomerization of dialkyl-1,3-allenedicarboxylates. Chirality 2002;14: 465-470.
    • (2002) Chirality , vol.14 , pp. 465-470
    • Trapp, O.1    Schurig, V.2
  • 47
    • 0037027489 scopus 로고    scopus 로고
    • Determination of the enantiomerization energy barrier of some 3-hydroxy-1,4-benzodiazepine drugs by supercritical fluid chromatography
    • Oswald P, Desmet K, Sandra P, Krupcik J, Majek P, Armstrong DW. Determination of the enantiomerization energy barrier of some 3-hydroxy-1,4-benzodiazepine drugs by supercritical fluid chromatography. J Chromatogr B 2002;779:283-295.
    • (2002) J Chromatogr B , vol.779 , pp. 283-295
    • Oswald, P.1    Desmet, K.2    Sandra, P.3    Krupcik, J.4    Majek, P.5    Armstrong, D.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.