메뉴 건너뛰기




Volumn 35, Issue 1-3, 1996, Pages 217-221

Anion-selective liquid-polymer optodes with fluorescent pH chromoionophores, tunable dynamic range and diffusion enhanced lifetimes

Author keywords

ETH 2412; ETH 2439; ETH 5350; Fiber optic chemical sensor; Nitrite ionophore I; Ruthenium(II) octaethyl porphyrin

Indexed keywords

CHARGE CARRIERS; FLUORESCENCE; ION SELECTIVE ELECTRODES; SERVICE LIFE;

EID: 0043139004     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)80058-5     Document Type: Article
Times cited : (20)

References (20)
  • 1
    • 0001006613 scopus 로고
    • Development of submicron chemical fiber optic sensors
    • W. Tan, Z.Y. Shi and R. Kopelman, Development of submicron chemical fiber optic sensors, Anal. Chem., 64 (1992) 2985-2990.
    • (1992) Anal. Chem. , vol.64 , pp. 2985-2990
    • Tan, W.1    Shi, Z.Y.2    Kopelman, R.3
  • 2
    • 0026933081 scopus 로고
    • Submicrometer intracellular chemical optical fiber sensors
    • W. Tan, Z.Y. Shi, S. Smith, D. Birnbaum and R. Kopelman, Submicrometer intracellular chemical optical fiber sensors, Science, 253 (1992) 778-781.
    • (1992) Science , vol.253 , pp. 778-781
    • Tan, W.1    Shi, Z.Y.2    Smith, S.3    Birnbaum, D.4    Kopelman, R.5
  • 3
    • 0022738127 scopus 로고
    • Polymer modification of fiber optic chemical sensors as a method of enhancing fluorescence signal for pH measurement
    • C. Munkholm, D.R. Walt, P.P. Milanovich and S.M. Klainer, Polymer modification of fiber optic chemical sensors as a method of enhancing fluorescence signal for pH measurement, Anal. Chem., 58 (1987) 1427-1430.
    • (1987) Anal. Chem. , vol.58 , pp. 1427-1430
    • Munkholm, C.1    Walt, D.R.2    Milanovich, P.P.3    Klainer, S.M.4
  • 4
    • 0001342171 scopus 로고
    • Selectivity of ion-sensitive bulk optodes
    • E. Bakker and W. Simon, Selectivity of ion-sensitive bulk optodes, Anal. Chem., 64 (1992) 1805-1812.
    • (1992) Anal. Chem. , vol.64 , pp. 1805-1812
    • Bakker, E.1    Simon, W.2
  • 5
    • 0026630286 scopus 로고
    • Theoretical aspects of bulk optode membranes
    • K. Seiler and W. Simon, Theoretical aspects of bulk optode membranes, Anal Chim. Acta, 266 (1992) 73-87.
    • (1992) Anal Chim. Acta , vol.266 , pp. 73-87
    • Seiler, K.1    Simon, W.2
  • 6
    • 0027501373 scopus 로고
    • Detection limit of ion-selective bulk optodes and corresponding electrodes
    • E. Bakker, M. Willer and E. Pretsch, Detection limit of ion-selective bulk optodes and corresponding electrodes, Anal. Chim. Acta, 282 (1993) 265-71.
    • (1993) Anal. Chim. Acta , vol.282 , pp. 265-271
    • Bakker, E.1    Willer, M.2    Pretsch, E.3
  • 7
    • 0030211070 scopus 로고    scopus 로고
    • Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range
    • M.R. Shortreed, E. Bakker and R. Kopelman, Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range, Anal. Chem., 68 (1996) 2656-2662.
    • (1996) Anal. Chem. , vol.68 , pp. 2656-2662
    • Shortreed, M.R.1    Bakker, E.2    Kopelman, R.3
  • 9
    • 0030588708 scopus 로고    scopus 로고
    • Lifetime enhancement of ultrasmall fluorescent liquid-polymeric membrane based optodes by diffusion induced self-recovery after photobleaching
    • M.R. Shortreed, E. Monson and R. Kopelman, Lifetime enhancement of ultrasmall fluorescent liquid-polymeric membrane based optodes by diffusion induced self-recovery after photobleaching, Anal. Chem., 68 (1996) 4015-4019.
    • (1996) Anal. Chem. , vol.68 , pp. 4015-4019
    • Shortreed, M.R.1    Monson, E.2    Kopelman, R.3
  • 10
    • 0027318943 scopus 로고
    • Synthesis and characterization of neutral hydrogen ion-selective chromoionophores for use in bulk optodes
    • E. Bakker, M. Lerchi, T. Rosatzin, B. Rusterholz and W. Simon, Synthesis and characterization of neutral hydrogen ion-selective chromoionophores for use in bulk optodes, Anal. Chim. Acta, 278 (1993) 211-25.
    • (1993) Anal. Chim. Acta , vol.278 , pp. 211-225
    • Bakker, E.1    Lerchi, M.2    Rosatzin, T.3    Rusterholz, B.4    Simon, W.5
  • 11
    • 4243855616 scopus 로고    scopus 로고
    • Utilization of lipophilic ionic additives in liquid-polymeric film-based optodes for selective anion activity measurements
    • in press
    • M.R. Shortreed, S.L.R. Barker and R. Kopelman, Utilization of lipophilic ionic additives in liquid-polymeric film-based optodes for selective anion activity measurements, Anal Chem., (1996) in press.
    • (1996) Anal Chem.
    • Shortreed, M.R.1    Barker, S.L.R.2    Kopelman, R.3
  • 12
    • 0000354750 scopus 로고
    • Two-parameter Debye-H ckel approximation for the evaluation of mean activity coefficients of 109 electrolytes
    • P.C. Meier, Two-parameter Debye-H ckel approximation for the evaluation of mean activity coefficients of 109 electrolytes, Anal. Chim. Acta, 136 (1982) 363-368.
    • (1982) Anal. Chim. Acta , vol.136 , pp. 363-368
    • Meier, P.C.1
  • 13
    • 84987584157 scopus 로고
    • Ion pairing and acid dissociation constants in poly(vinyl chloride)-based ion-selective electrode membranes
    • E.M.J. Verpoorte, A.D.C. Chan and D.J. Harrison, Ion pairing and acid dissociation constants in poly(vinyl chloride)-based ion-selective electrode membranes, Electroanalysis, 5 (1993) 845-854.
    • (1993) Electroanalysis , vol.5 , pp. 845-854
    • Verpoorte, E.M.J.1    Chan, A.D.C.2    Harrison, D.J.3
  • 14
    • 0002441594 scopus 로고
    • Properties of PVC based membranes used in ion-selective electrodes
    • R.D. Armstrong and G. Horvai, Properties of PVC based membranes used in ion-selective electrodes, Electrochim, Acta, 35 (1990) 1-7.
    • (1990) Electrochim, Acta , vol.35 , pp. 1-7
    • Armstrong, R.D.1    Horvai, G.2
  • 16
    • 0000020499 scopus 로고
    • Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity
    • E. Bakker, E. Malinowska, R.D. Schiller and M.E. Meyerhoff, Anion-selective membrane electrodes based on metalloporphyrins: the influence of lipophilic anionic and cationic sites on potentiometric selectivity, Talanta, 41 (1994) 881-890.
    • (1994) Talanta , vol.41 , pp. 881-890
    • Bakker, E.1    Malinowska, E.2    Schiller, R.D.3    Meyerhoff, M.E.4
  • 17
    • 84987589760 scopus 로고
    • Potentiometric anion selectivities of polymer membranes doped with indium(III)-porphyrins
    • S.B, Park, W. Matuszewski, M.E. Meyerhoff, Y.H. Liu and K.M. Kadish, Potentiometric anion selectivities of polymer membranes doped with indium(III)-porphyrins, Electronanalysis, 3 (1991) 909-916.
    • (1991) Electronanalysis , vol.3 , pp. 909-916
    • Park, S.B.1    Matuszewski, W.2    Meyerhoff, M.E.3    Liu, Y.H.4    Kadish, K.M.5
  • 19
    • 0001738932 scopus 로고
    • Ionic additives for ion-selective electrodes based on electrically charged carriers
    • U. Schauer, E. Bakker, U.E. Spichiger and E. Pretsch, Ionic additives for ion-selective electrodes based on electrically charged carriers, Anal. Chem., 66 (1994) 391-398.
    • (1994) Anal. Chem. , vol.66 , pp. 391-398
    • Schauer, U.1    Bakker, E.2    Spichiger, U.E.3    Pretsch, E.4
  • 20
    • 0001337219 scopus 로고
    • Aquocyanocobalt(III)-hepta(2-phenylethyl)-cobyrinate as a cationic carrier for nitrite-selective liquid-membrane electrodes
    • R. Stepánek, B. Kräutler, P. Schulthess, B. Lindemann, D. Ammann and W. Simon, Aquocyanocobalt(III)-hepta(2-phenylethyl)-cobyrinate as a cationic carrier for nitrite-selective liquid-membrane electrodes, Anal. Chim. Acta, 182 (1986) 83-90.
    • (1986) Anal. Chim. Acta , vol.182 , pp. 83-90
    • Stepánek, R.1    Kräutler, B.2    Schulthess, P.3    Lindemann, B.4    Ammann, D.5    Simon, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.