메뉴 건너뛰기




Volumn 190, Issue 3, 2003, Pages 145-154

In vitro toxicity and mutagenicity of CoCrMo and Ti6Al wear particles

Author keywords

Carcinogenicity; Endoprosthesis loosening; Endoprosthesis metallic wear particles; Mutagenicity; Toxicity

Indexed keywords

ALLOY; ALUMINUM DERIVATIVE; CHROMIUM DERIVATIVE; COBALT COMPLEX; DIMETHYL SULFOXIDE; HYPOXANTHINE PHOSPHORIBOSYLTRANSFERASE; MOLYBDENUM COMPLEX; TITANIUM DERIVATIVE; WATER;

EID: 0043135051     PISSN: 0300483X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0300-483X(03)00147-1     Document Type: Article
Times cited : (29)

References (34)
  • 1
    • 0028039950 scopus 로고
    • Sinus histiocytosis of pelvic lymph nodes after hip replacement. A histiocytic proliferation induced by cobalt-chromium and titanium
    • Albores-Saavedra J., Vuitch F., Delgado R., Wiley E. Sinus histiocytosis of pelvic lymph nodes after hip replacement. A histiocytic proliferation induced by cobalt-chromium and titanium. Am. J. Pathol. 18:(1):1994;83-90.
    • (1994) Am. J. Pathol. , vol.18 , Issue.1 , pp. 83-90
    • Albores-Saavedra, J.1    Vuitch, F.2    Delgado, R.3    Wiley, E.4
  • 2
    • 2042447026 scopus 로고
    • Standard practice for direct contact cell culture evaluation of materials for medical devices
    • Philadelphia, PA
    • American Society for Testing and Materials, 1987. Standard practice for direct contact cell culture evaluation of materials for medical devices. Designation: F 813-83, Annual book of ASTM standards, Philadelphia, PA, pp. 323-327.
    • (1987) Designation: F 813-83, Annual Book of ASTM Standards , pp. 323-327
  • 3
    • 0016685233 scopus 로고
    • Methods for detecting carcinogens and mutagens with salmonella/mammalian microsome mutagenicity test
    • Ames B.N., McCann J., Yamasaki E. Methods for detecting carcinogens and mutagens with salmonella/mammalian microsome mutagenicity test. Mutat. Res. 32:1975;347-364.
    • (1975) Mutat. Res. , vol.32 , pp. 347-364
    • Ames, B.N.1    McCann, J.2    Yamasaki, E.3
  • 4
    • 0021915153 scopus 로고
    • Chromium concentrations in serum, blood clot and urine from patients following total hip arthroplasty
    • Bartolozzi A., Black J. Chromium concentrations in serum, blood clot and urine from patients following total hip arthroplasty. Biomaterials. 6:1985;2-8.
    • (1985) Biomaterials , vol.6 , pp. 2-8
    • Bartolozzi, A.1    Black, J.2
  • 5
    • 0026550681 scopus 로고
    • Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal content and associated histological findings
    • Betts F., Wright T., Salvati E.A., Boskey A., Bansal M. Cobalt-alloy metal debris in periarticular tissues from total hip revision arthroplasties. Metal content and associated histological findings. Clin. Orthop. 276:1992;75-82.
    • (1992) Clin. Orthop. , vol.276 , pp. 75-82
    • Betts, F.1    Wright, T.2    Salvati, E.A.3    Boskey, A.4    Bansal, M.5
  • 6
    • 0024059621 scopus 로고
    • Does corrosion matter?
    • Black J. Does corrosion matter? JBJS. 70B:1988;517-520.
    • (1988) JBJS , vol.70 B , pp. 517-520
    • Black, J.1
  • 7
    • 0025102146 scopus 로고
    • Osteogenic sarcoma arising in the area of a total hip replacement
    • Brien W.W., Salvati E.A., Healy J.H., Bansal M., Ghelman B., Betts F. Osteogenic sarcoma arising in the area of a total hip replacement. JBJS. 72A:1990;1097-1099.
    • (1990) JBJS , vol.72 A , pp. 1097-1099
    • Brien, W.W.1    Salvati, E.A.2    Healy, J.H.3    Bansal, M.4    Ghelman, B.5    Betts, F.6
  • 8
    • 0026534146 scopus 로고
    • Metal levels in cemented total hip arthroplasty. A comparison of well fixed and loose implants
    • Brien W.W., Salvati E.A., Betts F., Morris D.M. Metal levels in cemented total hip arthroplasty. A comparison of well fixed and loose implants. Clin. Orthop. 276:1992;66-74.
    • (1992) Clin. Orthop. , vol.276 , pp. 66-74
    • Brien, W.W.1    Salvati, E.A.2    Betts, F.3    Morris, D.M.4
  • 9
    • 0033626538 scopus 로고    scopus 로고
    • Serumcobalt- und serumchromspiegel bei zwei chronisch niereninsuffizienten mit hüfttotalendoprothese und metall-metall-gleitpaarung
    • Brodner W., Grohs J.G., Bitzan P., Meisinger V., Kovarik J., Kotz R. Serumcobalt- und serumchromspiegel bei zwei chronisch niereninsuffizienten mit hüfttotalendoprothese und metall-metall-gleitpaarung. Z. Orthop. 138:2000;425-429.
    • (2000) Z. Orthop. , vol.138 , pp. 425-429
    • Brodner, W.1    Grohs, J.G.2    Bitzan, P.3    Meisinger, V.4    Kovarik, J.5    Kotz, R.6
  • 10
    • 0022532235 scopus 로고
    • Excessive metal release due to loosening and fretting of sintered particles on porous coated hip prostheses
    • Buchert P.K., Vaughn B.K., Mallory T.H., Engh C.A., Bobyn J.D. Excessive metal release due to loosening and fretting of sintered particles on porous coated hip prostheses. JBJS. 68A:1986;606-609.
    • (1986) JBJS , vol.68 A , pp. 606-609
    • Buchert, P.K.1    Vaughn, B.K.2    Mallory, T.H.3    Engh, C.A.4    Bobyn, J.D.5
  • 13
  • 14
    • 0021527489 scopus 로고
    • Sarcoma and joint replacement
    • Hamblen D.L., Carter R.L. Sarcoma and joint replacement. JBJS. 66B:1984;625-627.
    • (1984) JBJS , vol.66 B , pp. 625-627
    • Hamblen, D.L.1    Carter, R.L.2
  • 15
    • 0015233330 scopus 로고
    • Carcinogenic properties of wear particles from prostheses made in cobalt-chromium alloy
    • Heath J.C., Freeman M.A.R., Swanson S.A.V. Carcinogenic properties of wear particles from prostheses made in cobalt-chromium alloy. Lancet. 1:1971;564-566.
    • (1971) Lancet , vol.1 , pp. 564-566
    • Heath, J.C.1    Freeman, M.A.R.2    Swanson, S.A.V.3
  • 16
    • 0042085613 scopus 로고
    • A quantitative test for mutagenicity in V79 hamster cells
    • Kilbey et al. Amsterdam: Elsevier
    • Jensen D. A quantitative test for mutagenicity in V79 hamster cells. Kilbey, et al. Handbook of Mutagenicity Procedures. 1984;Elsevier, Amsterdam.
    • (1984) Handbook of Mutagenicity Procedures
    • Jensen, D.1
  • 17
    • 0036035526 scopus 로고    scopus 로고
    • Dissemination of wear particles after alloplastic replacement of the anterior cruciate ligament: A study based on animal trials
    • Katzer A. Dissemination of wear particles after alloplastic replacement of the anterior cruciate ligament: a study based on animal trials. J. Orthopaed. Traumatol. 3:2002;7-25.
    • (2002) J. Orthopaed. Traumatol. , vol.3 , pp. 7-25
    • Katzer, A.1
  • 18
    • 0036095812 scopus 로고    scopus 로고
    • Isolierte Femurschaftosteolysen bei festsitzenden zementierten Hüftgelenkstotalendoprothesen
    • Katzer A., Behnke B., Grabski H., von Foerster G. Isolierte Femurschaftosteolysen bei festsitzenden zementierten Hüftgelenkstotalendoprothesen. Akt. Traumatol. 32:2002;76-81.
    • (2002) Akt. Traumatol. , vol.32 , pp. 76-81
    • Katzer, A.1    Behnke, B.2    Grabski, H.3    Von Foerster, G.4
  • 21
    • 0001406666 scopus 로고
    • Detection of carcinogens in the salmonella microsome test: Assay of 300 chemicals
    • McCann J., Choi E., Yamasaki E., Ames B.N. Detection of carcinogens in the salmonella microsome test: assay of 300 chemicals. Proc. Nat. Acad. Sci. USA. 72:1975;5135.
    • (1975) Proc. Nat. Acad. Sci. USA , vol.72 , pp. 5135
    • McCann, J.1    Choi, E.2    Yamasaki, E.3    Ames, B.N.4
  • 22
    • 0026013091 scopus 로고
    • Systemic effects of implanted prostheses made of cobalt chromium alloys
    • Michel R., Nolte M., Reich M., Löer F. Systemic effects of implanted prostheses made of cobalt chromium alloys. Arch. Orthop. Trauma Surg. 110:1991;61-74.
    • (1991) Arch. Orthop. Trauma Surg. , vol.110 , pp. 61-74
    • Michel, R.1    Nolte, M.2    Reich, M.3    Löer, F.4
  • 23
    • 0024981149 scopus 로고
    • Kreftfremkallende metaller
    • Norseth T. Kreftfremkallende metaller. Tidskr. Nor. Laegefor. 109:1989;1638-1641.
    • (1989) Tidskr. Nor. Laegefor. , vol.109 , pp. 1638-1641
    • Norseth, T.1
  • 24
    • 0021689437 scopus 로고
    • Osteosarcoma in association with total hip replacement
    • Penman H.G., Ring P.A. Osteosarcoma in association with total hip replacement. JBJS. 66B:1984;632-634.
    • (1984) JBJS , vol.66 B , pp. 632-634
    • Penman, H.G.1    Ring, P.A.2
  • 25
    • 0018097153 scopus 로고
    • The haemolytic action of particulate metals (Cd,Cr,Co,Fe,Mo,Ni,Ta,Ti,Zn,Co-Cr alloy)
    • Rae T. The haemolytic action of particulate metals (Cd,Cr,Co,Fe,Mo,Ni,Ta,Ti,Zn,Co-Cr alloy). J. Pathol. 125:1978;81-89.
    • (1978) J. Pathol. , vol.125 , pp. 81-89
    • Rae, T.1
  • 26
    • 0026684913 scopus 로고
    • Metal carcinogenesis: Mechanistic implications
    • Snow E.T. Metal carcinogenesis: mechanistic implications. Pharmacol. Therapeut. 53:1992;31-65.
    • (1992) Pharmacol. Therapeut. , vol.53 , pp. 31-65
    • Snow, E.T.1
  • 27
    • 0021322355 scopus 로고
    • Recent advances in metal carcinogesis
    • Sunderman F.W. Recent advances in metal carcinogesis. Ann. Clin. Lab. Sci. 14:(2):1984;93-122.
    • (1984) Ann. Clin. Lab. Sci. , vol.14 , Issue.2 , pp. 93-122
    • Sunderman, F.W.1
  • 28
    • 0024670459 scopus 로고
    • Cobalt, chromium and nickel concentrations in body fluids of patients with porous coated knee or hip prostheses
    • Sunderman F.W., Hopfer S.M., Swift T., et al. Cobalt, chromium and nickel concentrations in body fluids of patients with porous coated knee or hip prostheses. J. Orthop. Res. 7:1989;307-315.
    • (1989) J. Orthop. Res. , vol.7 , pp. 307-315
    • Sunderman, F.W.1    Hopfer, S.M.2    Swift, T.3
  • 30
    • 0025963553 scopus 로고
    • Cancer risk after McKee-Farrar total hip replacement
    • Visuri T., Koskenvuo M. Cancer risk after McKee-Farrar total hip replacement. Orthopedics. 14:1991;137-142.
    • (1991) Orthopedics , vol.14 , pp. 137-142
    • Visuri, T.1    Koskenvuo, M.2
  • 31
    • 0028346902 scopus 로고
    • Life expectancy after hip arthroplasty. Case control study of 1018 cases of primary arthrosis
    • Visuri T., Pulkkinen P., Turula K.B., Paavolainen P., Koskenvuo M. Life expectancy after hip arthroplasty. Case control study of 1018 cases of primary arthrosis. Acta Orthop. Scand. 65:1994;9-11.
    • (1994) Acta Orthop. Scand. , vol.65 , pp. 9-11
    • Visuri, T.1    Pulkkinen, P.2    Turula, K.B.3    Paavolainen, P.4    Koskenvuo, M.5
  • 32
    • 0029789979 scopus 로고    scopus 로고
    • Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty
    • Visuri T., Pukkala E., Paavolainen P., Pulkkinen P., Riska E.B. Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin. Orthop. 329:1996;280-289.
    • (1996) Clin. Orthop. , vol.329 , pp. 280-289
    • Visuri, T.1    Pukkala, E.2    Paavolainen, P.3    Pulkkinen, P.4    Riska, E.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.