메뉴 건너뛰기




Volumn 5029, Issue , 2003, Pages 815-821

Dose optimization tool

Author keywords

CT; Dose; Dose reduction; Dose saving; Low dose; Noise

Indexed keywords

ALGORITHMS; CALCULATIONS; IMAGE RECONSTRUCTION; OPTIMIZATION; SCANNING; SPURIOUS SIGNAL NOISE; VISUALIZATION;

EID: 0043125878     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.482412     Document Type: Conference Paper
Times cited : (11)

References (7)
  • 1
    • 0032742081 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation
    • W. A. Kalender, H. Wolf and C. Suess, "Dose Reduction in CT by Anatomically Adapted Tube Current Modulation", Med. Phy. 26(11), 2248-53, 1999.
    • (1999) Med. Phy. , vol.26 , Issue.11 , pp. 2248-2253
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3
  • 2
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • T. F. Jakobs, C. R. Becker, B. Ohnesorge, T. Flohr, C. Suess, U. J. Schoepf, MF Reiser, "Multislice Helical CT of The Heart With Retrospective ECG Gating: Reduction of Radiation Exposure by ECG-Controlled Tube Current Modulation", Eur Radiol 12(5), 1081-6, 2002.
    • (2002) Eur Radiol , vol.12 , Issue.5 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3    Flohr, T.4    Suess, C.5    Schoepf, U.J.6    Reiser, M.F.7
  • 3
    • 0043033136 scopus 로고    scopus 로고
    • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (Care dose)
    • H. Greess, A. Nomayr, H. Wolf, U. Baum, M. Lell, B. Bowing, W. Kalender, W. A. Bautz, "Dose Reduction in CT Examination of Children By An Attenuation-Based On-Line Modulation of Tube Current (Care Dose)". Eur Radiol 12(6), 1571-6, 2002.
    • (2002) Eur Radiol , vol.12 , Issue.6 , pp. 1571-1576
    • Greess, H.1    Nomayr, A.2    Wolf, H.3    Baum, U.4    Lell, M.5    Bowing, B.6    Kalender, W.7    Bautz, W.A.8
  • 5
    • 0041577818 scopus 로고    scopus 로고
    • DoseRight advanced management software
    • Philips brochure
    • "DoseRight Advanced Management Software". Philips brochure.
  • 7
    • 0003574361 scopus 로고    scopus 로고
    • Hans Dieter Nagel Editor; Edited by Hans. Dieter Nagel, 2nd edition, COCIR
    • Hans Dieter Nagel Editor, "Radiation Exposure in Computed Tomography", Edited by Hans. Dieter Nagel, 2nd edition, COCIR, 2000.
    • (2000) Radiation Exposure in Computed Tomography


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.