메뉴 건너뛰기




Volumn 383, Issue 2-3, 1996, Pages 309-317

Picosecond timing of terawatt laser pulses with the SLAC 46 GeV electron beam

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROMAGNETIC FIELD EFFECTS; ELECTRON BEAMS; ELECTRON EMISSION; ELECTRON SCATTERING; LINEAR ACCELERATORS;

EID: 0043093690     PISSN: 01689002     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-9002(96)00828-5     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 0041818104 scopus 로고    scopus 로고
    • note
    • 3/(eℏ).
  • 2
    • 0042319009 scopus 로고
    • 0.5 Hz, phase-stabilized terawatt laser system with a Nd:Glass slab amplifier for nonlinear QED experiments
    • University of Rochester preprint, UR-1428, June submitted to
    • C. Bamber et al., 0.5 Hz, phase-stabilized terawatt laser system with a Nd:glass slab amplifier for nonlinear QED experiments, University of Rochester preprint, UR-1428, (June 1995), submitted to Laser Phys.
    • (1995) Laser Phys.
    • Bamber, C.1
  • 3
    • 6144296047 scopus 로고    scopus 로고
    • C. Bula et al., Phys. Rev. Lett. 76 (1996) 3116, see also C. Bula et al., Preliminary observation of nonlinear effects in Compton scattering presented at the 1995 Lepton-Photon Symp. Beijing, China.
    • (1996) Phys. Rev. Lett. , vol.76 , pp. 3116
    • Bula, C.1
  • 4
    • 6144296047 scopus 로고    scopus 로고
    • Preliminary observation of nonlinear effects in compton scattering
    • presented at the Beijing, China
    • C. Bula et al., Phys. Rev. Lett. 76 (1996) 3116, see also C. Bula et al., Preliminary observation of nonlinear effects in Compton scattering presented at the 1995 Lepton-Photon Symp. Beijing, China.
    • 1995 Lepton-Photon Symp.
    • Bula, C.1
  • 6
    • 0041317492 scopus 로고
    • SLAC-PUB-95-6841. Under optimal compression the pulse length of the SLC has σ∼ 1.2 ps. In the experiment the longer pulse length was chosen to reduce the effects of timing jitter
    • R.L. Holtzapple, Measurements of longitudinal phase space in the SLC LInac, SLAC-PUB-95-6841 (1995). Under optimal compression the pulse length of the SLC has σ∼ 1.2 ps. In the experiment the longer pulse length was chosen to reduce the effects of timing jitter.
    • (1995) Measurements of Longitudinal Phase Space in the SLC LInac
    • Holtzapple, R.L.1
  • 8
    • 0041317501 scopus 로고    scopus 로고
    • Lightwave Electronics Co., Mountain View, CA, USA
    • Model 1000 Timing Stabilizer, Lightwave Electronics Co., Mountain View, CA, USA.
    • Model 1000 Timing Stabilizer
  • 15
    • 0042820183 scopus 로고    scopus 로고
    • note
    • τ2 f(τ)dτ.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.