Volumn 31, Issue 7, 2003, Pages 509-518

Adhesion of porcelain to titanium and a titanium alloy

Author keywords

Adhesion; Interfacial bond energy; Porcelain; Titanium; Titanium alloy

Indexed keywords

CHROMIUM; ELEMENT; TITANIUM;

EID: 0043071591     PISSN: 03005712     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0300-5712(03)00071-X     Document Type: Article
Times cited : (71)

References (19)
  • 1
    • 0033222608 scopus 로고    scopus 로고
    • New approach for evaluating metal-porcelain interfacial bonding
    • Suansuwan N., Swain M.V. New approach for evaluating metal-porcelain interfacial bonding. Int J Prosthod. 12:1999;547-552.
    • (1999) Int J Prosthod , vol.12 , pp. 547-552
    • Suansuwan, N.1    Swain, M.V.2
  • 2
    • 0025444240 scopus 로고
    • Oxidation effects on porcelain-titanium interface reactions and bond strength
    • Kimura H., Horng C.J., Okazaki M., Takahashi J. Oxidation effects on porcelain-titanium interface reactions and bond strength. Dent Mater J. 9:1990;91-99.
    • (1990) Dent Mater J , vol.9 , pp. 91-99
    • Kimura, H.1    Horng, C.J.2    Okazaki, M.3    Takahashi, J.4
  • 3
    • 0025439635 scopus 로고
    • Oxide adherence and porcelain bonding to titanium and Ti-6Al-4V alloy
    • Adachi M., Mackert J.R. Jr., Parry E.E., Fairhurst C.W. Oxide adherence and porcelain bonding to titanium and Ti-6Al-4V alloy. J Dent Res. 69:1990;1230-1235.
    • (1990) J Dent Res , vol.69 , pp. 1230-1235
    • Adachi, M.1    Mackert J.R., Jr.2    Parry, E.E.3    Fairhurst, C.W.4
  • 4
    • 0031116287 scopus 로고    scopus 로고
    • Oxidation behavior of surface-modified titanium for titanium-ceramic restorations
    • Wang R.R., Fung K.K. Oxidation behavior of surface-modified titanium for titanium-ceramic restorations. J Prosthet Dent. 77:1997;423-434.
    • (1997) J Prosthet Dent , vol.77 , pp. 423-434
    • Wang, R.R.1    Fung, K.K.2
  • 5
    • 0028520542 scopus 로고
    • Effects of sandblasting and silica-coating procedures on pure titanium
    • Kern M., Thompson V.P. Effects of sandblasting and silica-coating procedures on pure titanium. J Dent. 22:1994;300-306.
    • (1994) J Dent , vol.22 , pp. 300-306
    • Kern, M.1    Thompson, V.P.2
  • 6
  • 7
    • 0032991686 scopus 로고    scopus 로고
    • Silicon nitride coating on titanium to enable titanium-ceramic bonding
    • Wang R.R., Welsch G.E., Monteiro O. Silicon nitride coating on titanium to enable titanium-ceramic bonding. J Biomed Mater Res. 46:1999;262-270.
    • (1999) J Biomed Mater Res , vol.46 , pp. 262-270
    • Wang, R.R.1    Welsch, G.E.2    Monteiro, O.3
  • 9
    • 0030162904 scopus 로고    scopus 로고
    • Strength of porcelain fused to titanium beams
    • White S.N., Ho L., Caputo A.A., Goo E. Strength of porcelain fused to titanium beams. J Prosthet Dent. 75:1996;640-648.
    • (1996) J Prosthet Dent , vol.75 , pp. 640-648
    • White, S.N.1    Ho, L.2    Caputo, A.A.3    Goo, E.4
  • 10
    • 0029181886 scopus 로고    scopus 로고
    • Bonding characteristics of low-fusing porcelain bonded to pure titanium and palladium-copper alloy
    • Pang I.C., Gilbert J.L., Chai J., Lautenschlager E.P. Bonding characteristics of low-fusing porcelain bonded to pure titanium and palladium-copper alloy. J Prosthet Dent. 73:1996;17-25.
    • (1996) J Prosthet Dent , vol.73 , pp. 17-25
    • Pang, I.C.1    Gilbert, J.L.2    Chai, J.3    Lautenschlager, E.P.4
  • 11
    • 0028402743 scopus 로고
    • Bond characteristics of porcelain fused to milled titanium
    • Gilbert J.L., Covey D.A., Lautenschlager E.P. Bond characteristics of porcelain fused to milled titanium. Dent Mater. 10:1994;134-140.
    • (1994) Dent Mater , vol.10 , pp. 134-140
    • Gilbert, J.L.1    Covey, D.A.2    Lautenschlager, E.P.3
  • 12
    • 0028500487 scopus 로고
    • Bonding of low-fusing dental porcelain to commercially pure titanium
    • Kononen M., Kivilahti J. Bonding of low-fusing dental porcelain to commercially pure titanium. J Biomed Mater Res. 28:1994;1027-1035.
    • (1994) J Biomed Mater Res , vol.28 , pp. 1027-1035
    • Kononen, M.1    Kivilahti, J.2
  • 13
    • 0030160162 scopus 로고    scopus 로고
    • Three-point binding strength of ceramics fused to cast titanium
    • Probster L., Maiwald U., Weber H. Three-point binding strength of ceramics fused to cast titanium. Eur J Oral Sci. 104:1996;313-319.
    • (1996) Eur J Oral Sci , vol.104 , pp. 313-319
    • Probster, L.1    Maiwald, U.2    Weber, H.3
  • 16
    • 0030699144 scopus 로고    scopus 로고
    • Evaluation of the strain energy release rate for the fracture of titanium-porcelain interfacial bonding
    • Chung H.G.P., Swain M.V., Mori T. Evaluation of the strain energy release rate for the fracture of titanium-porcelain interfacial bonding. Biomaterials. 18:1997;1553-1557.
    • (1997) Biomaterials , vol.18 , pp. 1553-1557
    • Chung, H.G.P.1    Swain, M.V.2    Mori, T.3
  • 17
    • 0035260939 scopus 로고    scopus 로고
    • Determination of elastic properties of metal alloys and dental porcelains
    • Suansuwan N., Swain M.V. Determination of elastic properties of metal alloys and dental porcelains. J Oral Rehabil. 28:2001;133-139.
    • (2001) J Oral Rehabil , vol.28 , pp. 133-139
    • Suansuwan, N.1    Swain, M.V.2
  • 19
    • 0031396387 scopus 로고    scopus 로고
    • CASINO: A new Monte Carlo code in C language for electron beam interaction - Part I: Description of the program
    • Hovington P., Drouin D., Gauvin R. CASINO: a new Monte Carlo code in C language for electron beam interaction - Part I: description of the program. Scanning. 19:1997;1-14.
    • (1997) Scanning , vol.19 , pp. 1-14
    • Hovington, P.1    Drouin, D.2    Gauvin, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.