메뉴 건너뛰기




Volumn 19, Issue 3, 2003, Pages 271-278

Development and reliability of a measurement device for flexion force of the first metatarsophalangeal joint

Author keywords

Aged; Hallux; Strength; Women

Indexed keywords

BIOMEDICAL EQUIPMENT; DYNAMOMETERS; JOINTS (ANATOMY); PATIENT TREATMENT;

EID: 0043023577     PISSN: 10658483     EISSN: None     Source Type: Journal    
DOI: 10.1123/jab.19.3.271     Document Type: Article
Times cited : (2)

References (12)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J.M., & Altman, D.G. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I, 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 0023204359 scopus 로고
    • Interrater reliability of hand-held dynamometry
    • Bohannon, R.W., & Andrews, A.W. (1987). Interrater reliability of hand-held dynamometry. Physical Therapy, 67, 931-933.
    • (1987) Physical Therapy , vol.67 , pp. 931-933
    • Bohannon, R.W.1    Andrews, A.W.2
  • 9
    • 0022092102 scopus 로고
    • Electromyographic patterns in adult locomotion: A comprehensive review
    • Shiavi, R. (1985). Electromyographic patterns in adult locomotion: A comprehensive review. Journal of Rehabilitation Research and Development, 22, 85-98.
    • (1985) Journal of Rehabilitation Research and Development , vol.22 , pp. 85-98
    • Shiavi, R.1
  • 10
    • 0018700926 scopus 로고
    • Forces acting on the metatarsals during normal walking
    • Stokes, I.A.F., Hutton, W.C., & Stott, J.R. (1979). Forces acting on the metatarsals during normal walking. Journal of Anatomy, 129, 579-590.
    • (1979) Journal of Anatomy , vol.129 , pp. 579-590
    • Stokes, I.A.F.1    Hutton, W.C.2    Stott, J.R.3
  • 11
    • 0029042486 scopus 로고
    • Reliability study of the MicroFET for pressure pain thresholds of myofascial trigger points in patients who have been operated on for herniated nucleus pulposi
    • van Essen, D., Aufdemkampe, G., Houvast, M., and Nijeboer, I. (1995). Reliability study of the MicroFET for pressure pain thresholds of myofascial trigger points in patients who have been operated on for herniated nucleus pulposi. Physiotherapy Theory and Practice, 11, 81-88.
    • (1995) Physiotherapy Theory and Practice , vol.11 , pp. 81-88
    • Van Essen, D.1    Aufdemkampe, G.2    Houvast, M.3    Nijeboer, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.